Catalog excerpts

Measuring Transducers and Signal Unit for DIN-rail mounting Wiring diagram Wiring diagram Wiring diagram Wiring diagram Multiple-Supply Unit serves for feeding of two-wire transmitter with direct voltage by output The single circuits are physically seperated to each other and are electronic fused to short circuit. Supply voltage: Pulsation factor: Signal circuit: approx. 30 mA by short circuit Supply voltage 2 x 18 V, resp. 4 x 18 V, non-stabbilized Signal circuit 2x 4...20 mA, resp. 4 x 4...20 mA Extra charges Line voltage 24 V 50 c/s serves for physically isolation and synchronous amplification or transducing of electrical standard signals. Incorporated supply voltage for supply of a two-wire measuring transmitter. Output signals are both a voltage 0...10 Vand a current signal 0/4...20 mA. Both output signals are related to their common negative pole. Supply voltage: approx. 18 V, non-stabilized, max. 25mA Voltage output: 0...10 V, short-circuit proof, max. 5 mA Current output: 0/4...20 mA, max. load 500 Q Physically isolation: between input-output-line voltage with isolation between input - output - line voltage Supply voltage: approx. 18 V, non-stabilized Extra charges Line voltage 24 V 50 c/s serves for controlling measuring values which are represented as electrical currents. A potential-free contact is switched when the corresponding presetted nominal value either is fallen short (min.- function) or is exceeded (max. function). Hysteresis and time delay are adjustable inside the unit by trimmers. Supply voltage: Nominal value: Time delay: Error limits Accuracy of nominal value setting: Temperature drift: Poti with scales 0...100 % Output: two potential-free contact, 250 V, 8 A corrections reserved

 Open the catalog to page 1

All Arthur Grillo GmbH catalogs and technical brochures

  1. data sheet mkm

    1 Pages

  2. data sheet AF1

    1 Pages

  3. data sheet O2T

    1 Pages

  4. data sheet ETF

    1 Pages

  5. data sheet edr

    1 Pages

  6. data sheet wbv

    1 Pages

  7. data sheet mbz

    1 Pages

  8. data sheet CM2

    1 Pages

  9. data sheet MID

    1 Pages

  10. SPECIAL

    18 Pages

  11. TEMPERATURE

    20 Pages

  12. Display

    14 Pages

  13. HUMIDITY

    21 Pages

  14. PRESSURE

    35 Pages

  15. data sheet

    2 Pages

  16. data sheet DS85

    2 Pages

  17. data sheet DA85

    1 Pages

  18. data sheet

    2 Pages

  19. data sheet DS85

    2 Pages

  20. SHT11/15

    1 Pages

  21. Orifice plate

    3 Pages

  22. SGI

    1 Pages

  23. Venturirohr

    4 Pages

  24. MR 90

    4 Pages

Archived catalogs

  1. MID

    1 Pages

  2. MINI90

    1 Pages

  3. RGF

    1 Pages

  4. WBV

    1 Pages

  5. DS85-P

    2 Pages

  6. DS85

    1 Pages

  7. DPCS200

    2 Pages

  8. WR 90

    1 Pages

  9. AQD / AQ72

    1 Pages

  10. TOUCHSCREEN

    1 Pages

  11. AD-72P

    1 Pages

  12. AD96TF

    1 Pages

  13. AD 72P-ST

    1 Pages

  14. AD 72P-WT

    1 Pages

  15. AD 96TF

    1 Pages

  16. AFD

    1 Pages

  17. AFD-TK

    1 Pages

  18. CM2

    1 Pages

  19. O2T

    1 Pages

  20. ST225

    1 Pages

  21. TR225

    1 Pages

  22. GS225

    1 Pages

  23. GIV

    1 Pages

  24. Flora II

    1 Pages

  25. AF 1

    1 Pages

  26. catalogue

    80 Pages