1. Catalogs
  2. Arthur Grillo GmbH
  3. SGI - measuring grid for air measurement in pipelines
video corpo

SGI - measuring grid for air measurement in pipelines
1 /1Page

SGI - measuring grid for air measurement in pipelines

SGI - measuring grid for air measurement in pipelines
1 /1Page

Catalog excerpts

SGI - measuring grid for air measurement in pipelines-1

For measure speed after the dynamic pressure method Arrangement of several cylinder pitot tube Central tubes with laterally attached probe tubes Material brass (up to 100 °C) or stainless steel (up to 450 °C) Pressure connection 6mm Mounting parts available The SGI is a special lattice arrangement of a plurality of cylinder probes, which are distributed over a cross section that can be at different flow distribution in a pipe found in a canal or a mean flow. The probe is connected to the grid and each pipe or channel dimensions can be customized. It can be made for the edge or square channel cross-sections. For larger sizes is usually required a thrust bearing. Specifications Construction: Pressure taps: Comment: The use of the differential Peritact 80 (± 1.5%) with the smallest range of 0...1 mbar results as a range for the lowest velocity 0...8 m / s. Grand calculation for cylinder position sensor and sensor grids: w = 200 x ∆р Cxρ The transmitter MKM (± 0.2%) and 2000-K10 Peritact (± 1%) with the smallest ranking of 0... 0.1 mbar as a result, the lowest range for velocity 0...3 m/s. Larger ranges are possible by adjusting the transmitter. central tubes with laterally attached probe tubes 6 mm ø plastic tubing for connection velocity in m/s differential pressure in mbar density at actual conditions in kg/m³ coefficient for cylindrical probe = 2 for Prandtl-pitot tube = 1 Measuring grid SGI Dimensions Other dimensions on request. ACCESSORIES Arthur Grillo GmbH • Am Sandbach 7 • 40878 Ratingen • phone 0 21 02 - 47 10 22 • fax 0 21 02 - 47 58 82 www.grillo-messgeraete.de/en • Email: [email protected] • web shop: www.sensor-store.de

 Open the catalog to page 1

All Arthur Grillo GmbH catalogs and technical brochures

  1. SPECIAL

    18  Pages

  2. TEMPERATURE

    20  Pages

  3. Display

    14  Pages

  4. HUMIDITY

    21  Pages

  5. PRESSURE

    35  Pages

  6. WR 200-F

    2  Pages

  7. SHT11/15

    1  Page

  8. Orifice plate

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.