Catalog excerpts
ORIFICE PLATE Pressure sensor in flow measurements of liquids Calculation of the orifice according to DIN EN ISO 5167 Use at higher temperatures and aggressive media Material steel (St37) or stainless steel (1.4301) Pressure socket integrated Installation length 65 mm Pressure stages up to PN40 Special versions available on request Orifice plates as differential pressure for flow measurement of liquids, gases or vapors. Installation in the pipeline between flanges with smooth sealing strips, the length 65 mm. The calculation of orifice plates according to DIN EN ISO 5167. The straight pipe should be as 10 x D (D = pipe inside diameter), the outlet section may be 5 times D. The choice of materials is based on temperature, pressure and aggressiveness of the medium. Special versions for higher pressures, higher temperatures or larger sizes may be requested, in accordance with the technical opportunities are made. Specification Construction: Execution: Orifice: Construction length: Pressure connection: Pressure stages: Max. temperature: orifice plate with a two-ring version material steel St37 A with ring chamber taps B with single bore-removal exchangeable, material stainless steel 1.4301 65 mm G1/2A, 100 mm long, Steel St35.8 PN1...PN40 380 °C constitution rings, pressure taps and disc-dazzle stainless steel 1.4571 PN1...PN40 400 °C Material: Pressure stages: Max. temperature: Prices for stainless steel on request In case of order please specify the pressure stage PN! Weight approx. in kg Arthur Grillo GmbH • Am Sandbach 7 • 40878 Ratingen • phone 0 21 02 - 47 10 22 • fax 0 21 02 - 47 58 82 www.grillo-messgeraete.de/en • Email: info@grillo-messgeraete.de • web shop: www.sensor-store.de
Open the catalog to page 1Arthur Grillo with flange MEASURING SECTION □ Pressure sensor in flow measurements of liquids □ Calculation of the orifice according to DIN EN ISO 5167 19205 □ Use at higher temperatures and aggressive media □ Material steel (St37) or stainless steel (1.4301) □ Pressure socket integrated □ Installation to weld in (form E) or with flanges (form F) □ Special versions available on request Measuring section and orifice plates with ring chamber fixed attached to the inlet pipe piece- and outlet page. These are run for the size range DN15 ... DN40. Pressure Connections: Pressure stages: orifice...
Open the catalog to page 2ORIFICE according to DIN 19206 Orifice plates with circular cross-section can be used for flow measurement of gases. The installation in the pipe between flanges with smooth sealing strips. The pressure tap is on the pipeline in a form Stand D upstream of the orifice plate (positive-pressure extraction) and D / 2 from current downward (negative pressure sampling) is attached. The calculation of orifice plates according to DIN EN ISO 5167 Specifications Version: form G according to DIN 19206 mounting between flanges according to DIN smooth on both sides, Form C 1000 mbar Kind of seal: Max....
Open the catalog to page 3All Arthur Grillo GmbH catalogs and technical brochures
-
data_sheets_kf_etf_atf_af
1 Pages
-
Data_sheet_gpm
1 Pages
-
data sheet DPC200-AC
2 Pages
-
data sheet DPC200-MOD
2 Pages
-
data sheet mkm
1 Pages
-
data sheet room sensor
1 Pages
-
data sheet venturi
4 Pages
-
data sheet AF1
1 Pages
-
data sheet PFT22
2 Pages
-
data sheet O2T
1 Pages
-
data sheet ETF
1 Pages
-
data sheet floraII
1 Pages
-
data sheet PU21 / PI21
1 Pages
-
data sheet edr
1 Pages
-
data sheet MINI90P
1 Pages
-
data sheet thermocouples
2 Pages
-
data sheet wbv
1 Pages
-
data sheet PFT28KA
2 Pages
-
data sheet AD72P
1 Pages
-
data sheet GS225
1 Pages
-
data sheet mini72
1 Pages
-
data sheet mbz
1 Pages
-
Datenblatt PFT28
2 Pages
-
data sheet PFT28
2 Pages
-
data sheet CM2
1 Pages
-
DIFFERENTIAL PRESSURE SENSOR
2 Pages
-
data sheet PFT25 series
2 Pages
-
data sheet AQD / AQ72
1 Pages
-
data sheet DA2000-S
2 Pages
-
data sheet touchscreen
1 Pages
-
data sheet WR200D
2 Pages
-
data sheet MID
1 Pages
-
SPECIAL
18 Pages
-
TEMPERATURE
20 Pages
-
Display
14 Pages
-
HUMIDITY
21 Pages
-
PRESSURE
35 Pages
-
DA2000 protected serie
2 Pages
-
data sheet MTA90
1 Pages
-
data sheet MINI90
1 Pages
-
WR 200-F
2 Pages
-
data sheet DS200
2 Pages
-
data sheet DPC200
2 Pages
-
data sheet DS85
2 Pages
-
data sheet DPC310
2 Pages
-
data sheet peritact 80
2 Pages
-
data sheet DA2000
3 Pages
-
data sheet DPC200R
2 Pages
-
data sheet Peritact2000
3 Pages
-
data sheet DA85
1 Pages
-
data sheet PFT30
2 Pages
-
data sheet DS85PE
2 Pages
-
O2T - flue gas tester for O2
1 Pages
-
MULTIPLE-SUPPLY UNIT SP225
1 Pages
-
ISOLATION AMPLIFIER TR225
1 Pages
-
LIMIT SWITCH GS225
1 Pages
-
CLIMATE TRANSMITTER PFT30
2 Pages
-
CLIMATE TRANSMITTER PFT28Ka
2 Pages
-
Process transmitter
1 Pages
-
DS - pressure switch
1 Pages
-
GPM - prozess transmitter
1 Pages
-
MINI90 - transmitter
1 Pages
-
MINI72 / MTA90 - transmitter
1 Pages
-
PTF28 - climate transmitter
2 Pages
-
SHT11/15
1 Pages
-
product category - pressure
33 Pages
-
product category - temperature
17 Pages
-
product category - humidity
15 Pages
-
product category - flow
30 Pages
-
product category - special
16 Pages
-
product category - display
12 Pages
-
product catalog low resolution
91 Pages
-
cylinder pitot tube MBZ
1 Pages
-
SGI
1 Pages
-
Venturirohr
4 Pages
-
Venturi-flowmeter EVR2000
1 Pages
-
MR 90
4 Pages
-
TOUCHSCREEN - display
1 Pages
-
AD96TF - digital indicator
1 Pages
-
AFD / AKD - analog indicator
1 Pages
-
About us and our products
24 Pages
Archived catalogs
-
MID
1 Pages
-
MINI90
1 Pages
-
RGF
1 Pages
-
WBV
1 Pages
-
DS85-P
2 Pages
-
DS85
1 Pages
-
DPCS200
2 Pages
-
WR 90
1 Pages
-
AQD / AQ72
1 Pages
-
TOUCHSCREEN
1 Pages
-
AD-72P
1 Pages
-
AD96TF
1 Pages
-
AD 72P-ST
1 Pages
-
AD 72P-WT
1 Pages
-
AD 96TF
1 Pages
-
AFD
1 Pages
-
AFD-TK
1 Pages
-
CM2
1 Pages
-
ice thickness controler EDR
1 Pages
-
O2T
1 Pages
-
WT225, VT225, WT225
1 Pages
-
ST225
1 Pages
-
SP225
1 Pages
-
TR225
1 Pages
-
GS225
1 Pages
-
GIV
1 Pages
-
Flora II
1 Pages
-
AF 1
1 Pages
-
catalogue
80 Pages