1. Catalogs
  2. Arthur Grillo GmbH
  3. MINI90 - transmitter
video corpo

MINI90 - transmitter
1 /1Page

MINI90 - transmitter

MINI90 - transmitter
1 /1Page

Catalog excerpts

MINI90 - transmitter-1

Temperature transmitter with Pt100 according DIN EN 60751 Analogue outputs 0...10 V or 4...20 mA Plastic case with protection class IP 65 Sensor tube from 9 mm stainless steel 1.4571 The MINI90 series is used for temperature measurement in pipes or ducts. Three versions are available: smooth probe tube for use in protective sleeves, perforated pipe probe tip for measurement in air ducts and pipes with G1/2A-screwing sensor for measurements in liquids. In the G1/2A-version the measuring insert can be replaced with the electronic, without demounting the tube. The sensor tube is made of stainless steel 1.4571, the head of ABS plastic. Specifications Smallest span: Max. temperature on probe: Sensor element: 2-wire technology Output: Supply voltage: threaded protection sleeve SHS-M90 4...20 mA, linear to temperature 13...30 Vdc, polarity arbitrary 3-wire technology Output: Supply voltage: Ambient temperature of Electronic: Case: Tube: Time constant: Weight: Tolerance limit: EMC: weld-in protection sleeve SHE-M 90 -10...0...+70 °C plastic ABS, light grey protection class IP 65 to EN60529 stainless steel, material no. 1.4571 check table pls. approx. 250 g < 0,25 % ± 0,15 °C tested according EN 61000-6-2, EN 61000-6-3, CE mark Time constants at different conditions: time constant sec. Medium: Water 37 no flow 33 flow 2 m/s 73 with protection sleeve,brass 50 with protection sleeve, brass oil-filled 85 with protection sleeve, steel with protection sleeve, steel oil-filled 45 Medium: Air no flow flow 10 m/s Item no. Duct temperature transmitter MINI90 plan tube Measurement range: Customer-specific presetting required! Measurement range: Customer-specific presetting required! Duct temperature transmitter MINI90 Measurement range: Customer-specific presetting required! Measurement range: Customer-specific presetting required! Duct temperature transmitter MINI90 welded screwing G1/2A, mounting length 100 mm Measurement range: Customer-specific presetting required! Measurement range: Customer-specific presetting required! ACCESSORIES Mounting flange MF-M 90 for air ducts Threaded protection sleeve SHS-M 90, brass, brass, brazed Weld-in protection sleeve SHE-M 90 St37 PN40 Customer-specific presetting required!

 Open the catalog to page 1

All Arthur Grillo GmbH catalogs and technical brochures

  1. SPECIAL

    18  Pages

  2. TEMPERATURE

    20  Pages

  3. Display

    14  Pages

  4. HUMIDITY

    21  Pages

  5. PRESSURE

    35  Pages

  6. WR 200-F

    2  Pages

  7. SHT11/15

    1  Page

  8. Orifice plate

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.