Catalog excerpts
LIMIT SWITCH GS225 □ Limit switch for monitoring unit signals □ Two adjustable limit values (floating) □ Switching function min. or max. □ Potentiometer with scale 0...100% □ Hysteresis and time delay is adjustable □ Inputs 0/0, 2...1 V, 0/2...10 V, 0/4...20 mA □ Supply voltage 18...30 Vdc unregulated □ Supply voltage 230 Vac/115 Vac or 24 Vac or 24 Vdc □ Plastic housing for mounting on a 35 mm standard mounting DIN-rail according to EN 50022 Serves for controlling measuring values which are represented as electrical currents. A potential-free contact is switched when the corresponding presetted nomial value eith is fallen short (min.-function) or is exceded (max. function). Hysteresis and time delay are adjustable inside the unit by trimmers. ACCURACY/ERROR LIMIT: Temperature drift: ± 0,2 % / 10 K Entrance: Supply voltage: Setpoint setting: Hysteresis: Time Delay: Switching function: Contact output: Resolution of the scales: TECHNICAL SPECIFICATIONS: 0 / 0.2 ... 1 V, 0/2 ... 10 V, 0/4 ... 20 mA Approx. 18 ... 23 Vdc, unstabilized Poti with scale 0 ... 100% Adjustable in the device from 0.25 ... 5% Adjustable in the device from 0 ... 7 s Min. Or max. (Adjustable in the device) Potential-free NO contact max. 250 Vac, 8 A Approx. 5% Display: Casing: Dimensions: Protection class: Connections: Ambient temperature: Rel. humidity: Weight: PHYSICAL: Operating indicator green Polyamide gray, for mounting on a 35 mm standard profile rail according to EN 50022 22.5 x 99 x 110 mm (WxHxD) IP 20 according to EN 60529 Screw terminals up to 2.5 mm2 -10 to 50 ° C 0 ... 85%, no condensation Approx. 160 g Power supply: Power consumption: Test sockets: Voltage output: Current output: Max. Output current: ELECTRONIC: 230 Vac / 115 Vac Approx. 1.5 VA 2 mm 0 for measuring the output current, internal resistance of the current meter max. 10 Q 0 ... 10 V, short circuit proof, max. 5 mA 0/4 ... 20 mA, max. Load 600 Q Approx. 30 mA with short circuit SPECIAL CONFORMITY: EMC: EN 61000-6-2, EN 61000-6-3, CE-mark RoHS: according RoHS-directive 2011/65/EU Limit switch GS225 5592 Input: Customer-specific presetting required! Output: two potential-free contact, 250 Vac, 8 A Function switch 1: Customer-specific presetting required! Function switch 2: Customer-specific presetting required! Line voltage: 230/115 Vac, 24 Vac or 24 Vdc Customer-specific presetting required! Arthur Grillo GmbH • Am Sandbach 7 • 40878 Ratingen • phone 0 21 02 - 47 10 22 • fax 0 21 02 - 47 58 82 www.grillo-messgeraete.de/en • Email: info@grillo-messgeraete.de • web shop: www.sensor-store.de
Open the catalog to page 1All Arthur Grillo GmbH catalogs and technical brochures
-
data_sheets_kf_etf_atf_af
1 Pages
-
Data_sheet_gpm
1 Pages
-
data sheet DPC200-AC
2 Pages
-
data sheet DPC200-MOD
2 Pages
-
data sheet mkm
1 Pages
-
data sheet room sensor
1 Pages
-
data sheet venturi
4 Pages
-
data sheet AF1
1 Pages
-
data sheet PFT22
2 Pages
-
data sheet O2T
1 Pages
-
data sheet ETF
1 Pages
-
data sheet floraII
1 Pages
-
data sheet PU21 / PI21
1 Pages
-
data sheet edr
1 Pages
-
data sheet MINI90P
1 Pages
-
data sheet thermocouples
2 Pages
-
data sheet wbv
1 Pages
-
data sheet PFT28KA
2 Pages
-
data sheet AD72P
1 Pages
-
data sheet GS225
1 Pages
-
data sheet mini72
1 Pages
-
data sheet mbz
1 Pages
-
Datenblatt PFT28
2 Pages
-
data sheet PFT28
2 Pages
-
data sheet CM2
1 Pages
-
DIFFERENTIAL PRESSURE SENSOR
2 Pages
-
data sheet PFT25 series
2 Pages
-
data sheet AQD / AQ72
1 Pages
-
data sheet DA2000-S
2 Pages
-
data sheet touchscreen
1 Pages
-
data sheet WR200D
2 Pages
-
data sheet MID
1 Pages
-
SPECIAL
18 Pages
-
TEMPERATURE
20 Pages
-
Display
14 Pages
-
HUMIDITY
21 Pages
-
PRESSURE
35 Pages
-
DA2000 protected serie
2 Pages
-
data sheet MTA90
1 Pages
-
data sheet MINI90
1 Pages
-
WR 200-F
2 Pages
-
data sheet DS200
2 Pages
-
data sheet DPC200
2 Pages
-
data sheet DS85
2 Pages
-
data sheet DPC310
2 Pages
-
data sheet peritact 80
2 Pages
-
data sheet DA2000
3 Pages
-
data sheet DPC200R
2 Pages
-
data sheet Peritact2000
3 Pages
-
data sheet DA85
1 Pages
-
data sheet PFT30
2 Pages
-
data sheet DS85PE
2 Pages
-
O2T - flue gas tester for O2
1 Pages
-
MULTIPLE-SUPPLY UNIT SP225
1 Pages
-
ISOLATION AMPLIFIER TR225
1 Pages
-
CLIMATE TRANSMITTER PFT30
2 Pages
-
CLIMATE TRANSMITTER PFT28Ka
2 Pages
-
Process transmitter
1 Pages
-
DS - pressure switch
1 Pages
-
GPM - prozess transmitter
1 Pages
-
MINI90 - transmitter
1 Pages
-
MINI72 / MTA90 - transmitter
1 Pages
-
PTF28 - climate transmitter
2 Pages
-
SHT11/15
1 Pages
-
Orifice plate
3 Pages
-
product category - pressure
33 Pages
-
product category - temperature
17 Pages
-
product category - humidity
15 Pages
-
product category - flow
30 Pages
-
product category - special
16 Pages
-
product category - display
12 Pages
-
product catalog low resolution
91 Pages
-
cylinder pitot tube MBZ
1 Pages
-
SGI
1 Pages
-
Venturirohr
4 Pages
-
Venturi-flowmeter EVR2000
1 Pages
-
MR 90
4 Pages
-
TOUCHSCREEN - display
1 Pages
-
AD96TF - digital indicator
1 Pages
-
AFD / AKD - analog indicator
1 Pages
-
About us and our products
24 Pages
Archived catalogs
-
MID
1 Pages
-
MINI90
1 Pages
-
RGF
1 Pages
-
WBV
1 Pages
-
DS85-P
2 Pages
-
DS85
1 Pages
-
DPCS200
2 Pages
-
WR 90
1 Pages
-
AQD / AQ72
1 Pages
-
TOUCHSCREEN
1 Pages
-
AD-72P
1 Pages
-
AD96TF
1 Pages
-
AD 72P-ST
1 Pages
-
AD 72P-WT
1 Pages
-
AD 96TF
1 Pages
-
AFD
1 Pages
-
AFD-TK
1 Pages
-
CM2
1 Pages
-
ice thickness controler EDR
1 Pages
-
O2T
1 Pages
-
WT225, VT225, WT225
1 Pages
-
ST225
1 Pages
-
SP225
1 Pages
-
TR225
1 Pages
-
GS225
1 Pages
-
GIV
1 Pages
-
Flora II
1 Pages
-
AF 1
1 Pages
-
catalogue
80 Pages