Catalog excerpts

DIFFERENTIAL PRESSURE SENSOR DS85-P...E Diaphragm element Measuring range 0...50 Pa to 0...6000 Pa 4 calibrated measuring ranges selectable via DIP-switch Analogue output signal 0...10 V Supply voltage 15...30 Vdc or 24 Vac (±15%) Compact plastic housing IP 54; UL 94 HB The differential pressure sensor DS85-P...E is used to measure small differential pressures in ventilation and air conditioning. The measurement range from 0...50 Pa up to 0...6000 Pa is divided in three measurement groups. Each group has four calibrated measurement ranges, which are selectable by two DIP-Switches. Specifications Measuring substance: Sensor: Lowest range: Widest range: air or non aggressive gases silicone membrane with measuring spring and differential transformer 0...50 Pa 0...6000 Pa Measurement range selectable by: 2 pol DIP-switch hose liners 5 mm ø and 6 mm ø UL 94 HB; ultra mid with hinged ABS cover, cable inlet M16x1,5, screw terminals, electronic protected against false polarity Supply voltage: Power Consumption: Output: Characteristics: Pressure Connections: Housing: Electrical Connections: Overload protection: Static pressure: 15...30 Vdc; 24 Vac (+/-15%) approx. 5 mA at 15 Vdc; approx. 12 mA at 30 Vdc 0...10 V; Imax = 2 mA linear Protection class: Ambient temperature: Storage temperature: Weight: Operating position: IP 54 according EN 60529 -10...+50 °C -25...+60 °C approx. 250 g vertical, Position sensitivity when turned by 90° about 25 Pa tested according EN 61000-6-2, EN 61000-6-3, CE mark

 Open the catalog to page 1

high ohm: alarm off low ohm: alarm on maximum customer circuit 30 Vdc / 30 mA 8 Alarm output: Open Collector DIFFERENTIAL PRESSURE SENSOR DS85-P...E Error limits (related to the actual range) DPC200 1 Zero deviation Final Vdc oder 24 Vac (±15%) Versorgung Linearity Resolution + 10...30 value Alarm Ausgang: Open Collector DS85-P6000E Potentialfreier Kontakt offen: Sollwert 1 ± 0.5 % ± 0.25 % geschlossen: Sollwert 2 ± 0.9 % ± 0.9 % 0.3 % Alarm Ausgang hochohmig: Alarm aus ±1% ± 1.25 % 0.3 % niederohmig: Alarm an maximaler externer Stromkreis: 30 Vdc / 30 mA Temperature drift (relating to the...

 Open the catalog to page 2

All Arthur Grillo GmbH catalogs and technical brochures

  1. data sheet mkm

    1 Pages

  2. data sheet AF1

    1 Pages

  3. data sheet O2T

    1 Pages

  4. data sheet ETF

    1 Pages

  5. data sheet edr

    1 Pages

  6. data sheet wbv

    1 Pages

  7. data sheet mbz

    1 Pages

  8. data sheet CM2

    1 Pages

  9. data sheet MID

    1 Pages

  10. SPECIAL

    18 Pages

  11. TEMPERATURE

    20 Pages

  12. Display

    14 Pages

  13. HUMIDITY

    21 Pages

  14. PRESSURE

    35 Pages

  15. data sheet

    2 Pages

  16. data sheet DS85

    2 Pages

  17. data sheet DA85

    1 Pages

  18. data sheet

    2 Pages

  19. data sheet DS85

    2 Pages

  20. SHT11/15

    1 Pages

  21. Orifice plate

    3 Pages

  22. SGI

    1 Pages

  23. Venturirohr

    4 Pages

  24. MR 90

    4 Pages

Archived catalogs

  1. MID

    1 Pages

  2. MINI90

    1 Pages

  3. RGF

    1 Pages

  4. WBV

    1 Pages

  5. DS85-P

    2 Pages

  6. DS85

    1 Pages

  7. DPCS200

    2 Pages

  8. WR 90

    1 Pages

  9. AQD / AQ72

    1 Pages

  10. TOUCHSCREEN

    1 Pages

  11. AD-72P

    1 Pages

  12. AD96TF

    1 Pages

  13. AD 72P-ST

    1 Pages

  14. AD 72P-WT

    1 Pages

  15. AD 96TF

    1 Pages

  16. AFD

    1 Pages

  17. AFD-TK

    1 Pages

  18. CM2

    1 Pages

  19. O2T

    1 Pages

  20. ST225

    1 Pages

  21. SP225

    1 Pages

  22. TR225

    1 Pages

  23. GS225

    1 Pages

  24. GIV

    1 Pages

  25. Flora II

    1 Pages

  26. AF 1

    1 Pages

  27. catalogue

    80 Pages