Catalog excerpts
Differential Pressure Controller DPC 200 Diagraphm element with differtial transformator Measuring range from 0...50 Pa up to 0...6000 Pa alphanumeric LCD-display Analog output 0...10 V Controlling mode or measuring mode selectable Controlling mode with PI algorithm 2 setpoints adjustable Selectable measurands (diff. pressure or volume flow) Selectable units (metric or imperial) Maximum output voltage adjustable Supply voltage 10...30 Vdc; 24 Vac (+/-15%) Low pressure sensor with PI controlling mode compact palstic housing IP 54 The differntial pressure sensor DPC200 serve for measuring low pressure of non-aggressive gases, particulary of air. The customer can use an analog signal (0...10V). The device offers two different settings. On the one hand the output signal stands for a pressure proportional signal during measuring mode, or the output is the square root signal during volume flow measurement. And on the other hand the output signal stands for a PI control signal during controlling mode. The device can control differential pressure and volume flow. This device is mainly for e.g. in air conditioning systems for fan controlling, for pressure control of rooms or filter controlling. Technical data Measuring medium: Measuring principle: Lowest span: Highest span: Overpressure protection: Static pressure: Pressure connections: Case: Supply voltage: Current consumption: Output: Display: Mode: Controlling algorithm: Setpoints: Protection class: Ambient temperature: Weight: Mounting: Interference emmission: Influences limits: Air or non-aggressive gases Silicon diaphragm with spring and differential transformator 0...50 Pa 0...6000 Pa 0,2 bar max. 0,2 bar hose liners 5 mm ø and 6 mm ø Case polyamid, cover ABS 10...30 Vdc or 24 Vac ± 15 % Elctronic protection against faulty polarization approx. 12 mA (@24 Vdc) 0...10 V LCD-Display, 2x16 characters Measuring mode or controlling mode PI 2 setpoints adjustable within software, Setpoints are selectable with floating contact input IP 54 acording EN60529 0...+50 °C approx. 90 g vertical, position dependence by turning of 90°: approx. 25 Pa According EN 50081-2, EN 50082-2, CE Zero error: Sum of linearity and hysteresis (depends on measuring range): Temperature drift, zero point: Temperature drift, span:
Open the catalog to page 1Differential Pressure Controller DPC 200 Electrical connection Describtion Differential Pressure controller DPC200 Output: 0...10V Supply voltage 10...30 Vdc; 24 Vac (+/-15%) Measuring range (Pa): please specify Mounting set M-DS with screws, bleeders and 2m plastic tube 2566 from 10 piece from 50 piece from 100 piece March 2013 subject to change
Open the catalog to page 2All Arthur Grillo GmbH catalogs and technical brochures
-
data_sheets_kf_etf_atf_af
1 Pages
-
Data_sheet_gpm
1 Pages
-
data sheet DPC200-AC
2 Pages
-
data sheet DPC200-MOD
2 Pages
-
data sheet mkm
1 Pages
-
data sheet room sensor
1 Pages
-
data sheet venturi
4 Pages
-
data sheet AF1
1 Pages
-
data sheet PFT22
2 Pages
-
data sheet O2T
1 Pages
-
data sheet ETF
1 Pages
-
data sheet floraII
1 Pages
-
data sheet PU21 / PI21
1 Pages
-
data sheet edr
1 Pages
-
data sheet MINI90P
1 Pages
-
data sheet thermocouples
2 Pages
-
data sheet wbv
1 Pages
-
data sheet PFT28KA
2 Pages
-
data sheet AD72P
1 Pages
-
data sheet GS225
1 Pages
-
data sheet mini72
1 Pages
-
data sheet mbz
1 Pages
-
Datenblatt PFT28
2 Pages
-
data sheet PFT28
2 Pages
-
data sheet CM2
1 Pages
-
DIFFERENTIAL PRESSURE SENSOR
2 Pages
-
data sheet PFT25 series
2 Pages
-
data sheet AQD / AQ72
1 Pages
-
data sheet DA2000-S
2 Pages
-
data sheet touchscreen
1 Pages
-
data sheet WR200D
2 Pages
-
data sheet MID
1 Pages
-
SPECIAL
18 Pages
-
TEMPERATURE
20 Pages
-
Display
14 Pages
-
HUMIDITY
21 Pages
-
PRESSURE
35 Pages
-
DA2000 protected serie
2 Pages
-
data sheet MTA90
1 Pages
-
data sheet MINI90
1 Pages
-
WR 200-F
2 Pages
-
data sheet DS200
2 Pages
-
data sheet DPC200
2 Pages
-
data sheet DS85
2 Pages
-
data sheet DPC310
2 Pages
-
data sheet peritact 80
2 Pages
-
data sheet DA2000
3 Pages
-
data sheet DPC200R
2 Pages
-
data sheet Peritact2000
3 Pages
-
data sheet DA85
1 Pages
-
data sheet PFT30
2 Pages
-
data sheet DS85PE
2 Pages
-
O2T - flue gas tester for O2
1 Pages
-
MULTIPLE-SUPPLY UNIT SP225
1 Pages
-
ISOLATION AMPLIFIER TR225
1 Pages
-
LIMIT SWITCH GS225
1 Pages
-
CLIMATE TRANSMITTER PFT30
2 Pages
-
CLIMATE TRANSMITTER PFT28Ka
2 Pages
-
Process transmitter
1 Pages
-
DS - pressure switch
1 Pages
-
GPM - prozess transmitter
1 Pages
-
MINI90 - transmitter
1 Pages
-
MINI72 / MTA90 - transmitter
1 Pages
-
PTF28 - climate transmitter
2 Pages
-
SHT11/15
1 Pages
-
Orifice plate
3 Pages
-
product category - pressure
33 Pages
-
product category - temperature
17 Pages
-
product category - humidity
15 Pages
-
product category - flow
30 Pages
-
product category - special
16 Pages
-
product category - display
12 Pages
-
product catalog low resolution
91 Pages
-
cylinder pitot tube MBZ
1 Pages
-
SGI
1 Pages
-
Venturirohr
4 Pages
-
Venturi-flowmeter EVR2000
1 Pages
-
MR 90
4 Pages
-
TOUCHSCREEN - display
1 Pages
-
AD96TF - digital indicator
1 Pages
-
AFD / AKD - analog indicator
1 Pages
-
About us and our products
24 Pages
Archived catalogs
-
MID
1 Pages
-
MINI90
1 Pages
-
RGF
1 Pages
-
WBV
1 Pages
-
DS85-P
2 Pages
-
DS85
1 Pages
-
WR 90
1 Pages
-
AQD / AQ72
1 Pages
-
TOUCHSCREEN
1 Pages
-
AD-72P
1 Pages
-
AD96TF
1 Pages
-
AD 72P-ST
1 Pages
-
AD 72P-WT
1 Pages
-
AD 96TF
1 Pages
-
AFD
1 Pages
-
AFD-TK
1 Pages
-
CM2
1 Pages
-
ice thickness controler EDR
1 Pages
-
O2T
1 Pages
-
WT225, VT225, WT225
1 Pages
-
ST225
1 Pages
-
SP225
1 Pages
-
TR225
1 Pages
-
GS225
1 Pages
-
GIV
1 Pages
-
Flora II
1 Pages
-
AF 1
1 Pages
-
catalogue
80 Pages