Catalog excerpts
DIFFERENTIAL PRESSURE / VOLUME FLOW CONTROLLER DPC200 Electromechanical diaphragm measuring system Measuring range from 0...50 Pa (0.5 mbar) up to 0...6000 Pa (60 mbar) Alphanumeric LCD-display Analogue output 0...10 V Selectable measurements (differential pressure or volume flow) Selectable units (metric or imperial) Adjustable k-factor for volume flow calculation Controlling mode or measuring mode selectable Measuring mode with adjustable limit value Control mode with adjustable: - 2 setpoints - PI parameters for PI algorithm - maximum output voltage Supply voltage 10...30 Vdc; 24 Vac (+/-15%) Compact plastic housing IP 54 The DPCs are electromechanical differential pressure / volume flow controllers with a diaphragm measuring system and a comprehensive evaluation software. They are used to measure and control the smallest differential pressures of non-aggressive gases, in particular of air. Their optimal application area can be found in the field of climatic technology for controlling fans, room pressure monitoring or filter control. The devices allow controlling of air flow or keeping up a constant pressure in a closed environment. In addition to the analog output, an additional alarm output (open collector, max. 30 V / 30 mA or relay 250 Vac / 10 A) is available for limit monitoring or filter monitoring. The device provides a radiated output signal as a volumetric flow sensor. In the case of the pressure or volume flow control, the output signal is the manipulated variable of the PI control. Connection diagram DPC200 + 10...30 Vdc or 24 Vac (±15%) excitation - GND (return) + 0...10 Vdc output - GND (return) dry contact open: Setpoint 1 close: Setpoint 2 alarm output high ohm: alarm off low ohm: alarm on maximum customer circuit 30 Vdc / 30 mA Alarm output: Open Collector Alarm Ausgang: Open Collector + 10...30 Vdc oder 24 Vac (±15%) Versorgung - GND + 0...10 Vdc Ausgang - GND Potentialfreier Kontakt offen: Sollwert 1 geschlossen: Sollwert 2 . Alarm Ausgang hochohmig: Alarm aus niederohmig: Alarm an maximaler externer Stromkreis: 30 Vdc / 30 mA
Open the catalog to page 1DIFFERENTIAL PRESSURE / VOLUME FLOW CONTROLLER DPC200 Overpressure protection: Static pressure: Zero point calibration: Reaction time: PERFORMANCE: 0.2 bar max. 0.2 bar Adjustable by REEDcontact, no cyclic zero-point calibration required direct Zero drift: Sum of linearity and hysteresis: Temperature drift zero point: Temperature drift measuring range: Operating mode: Measuring medium: Measuring principle: Measuring unit: Smallest measuring range: Largest measuring range: Measuring range: Measuring range selection: Adjustable controlling parameters: Characteristic: Ambient...
Open the catalog to page 2All Arthur Grillo GmbH catalogs and technical brochures
-
data_sheets_kf_etf_atf_af
1 Pages
-
Data_sheet_gpm
1 Pages
-
data sheet DPC200-AC
2 Pages
-
data sheet DPC200-MOD
2 Pages
-
data sheet mkm
1 Pages
-
data sheet room sensor
1 Pages
-
data sheet venturi
4 Pages
-
data sheet AF1
1 Pages
-
data sheet PFT22
2 Pages
-
data sheet O2T
1 Pages
-
data sheet ETF
1 Pages
-
data sheet floraII
1 Pages
-
data sheet PU21 / PI21
1 Pages
-
data sheet edr
1 Pages
-
data sheet MINI90P
1 Pages
-
data sheet thermocouples
2 Pages
-
data sheet wbv
1 Pages
-
data sheet PFT28KA
2 Pages
-
data sheet AD72P
1 Pages
-
data sheet GS225
1 Pages
-
data sheet mini72
1 Pages
-
data sheet mbz
1 Pages
-
Datenblatt PFT28
2 Pages
-
data sheet PFT28
2 Pages
-
data sheet CM2
1 Pages
-
DIFFERENTIAL PRESSURE SENSOR
2 Pages
-
data sheet PFT25 series
2 Pages
-
data sheet AQD / AQ72
1 Pages
-
data sheet DA2000-S
2 Pages
-
data sheet touchscreen
1 Pages
-
data sheet WR200D
2 Pages
-
data sheet MID
1 Pages
-
SPECIAL
18 Pages
-
TEMPERATURE
20 Pages
-
Display
14 Pages
-
HUMIDITY
21 Pages
-
PRESSURE
35 Pages
-
DA2000 protected serie
2 Pages
-
data sheet MTA90
1 Pages
-
data sheet MINI90
1 Pages
-
WR 200-F
2 Pages
-
data sheet DS200
2 Pages
-
data sheet DPC200
2 Pages
-
data sheet DS85
2 Pages
-
data sheet DPC310
2 Pages
-
data sheet peritact 80
2 Pages
-
data sheet DA2000
3 Pages
-
data sheet DPC200R
2 Pages
-
data sheet Peritact2000
3 Pages
-
data sheet DA85
1 Pages
-
data sheet PFT30
2 Pages
-
data sheet DS85PE
2 Pages
-
O2T - flue gas tester for O2
1 Pages
-
MULTIPLE-SUPPLY UNIT SP225
1 Pages
-
ISOLATION AMPLIFIER TR225
1 Pages
-
LIMIT SWITCH GS225
1 Pages
-
CLIMATE TRANSMITTER PFT30
2 Pages
-
CLIMATE TRANSMITTER PFT28Ka
2 Pages
-
Process transmitter
1 Pages
-
DS - pressure switch
1 Pages
-
GPM - prozess transmitter
1 Pages
-
MINI90 - transmitter
1 Pages
-
MINI72 / MTA90 - transmitter
1 Pages
-
PTF28 - climate transmitter
2 Pages
-
SHT11/15
1 Pages
-
Orifice plate
3 Pages
-
product category - pressure
33 Pages
-
product category - temperature
17 Pages
-
product category - humidity
15 Pages
-
product category - flow
30 Pages
-
product category - special
16 Pages
-
product category - display
12 Pages
-
product catalog low resolution
91 Pages
-
cylinder pitot tube MBZ
1 Pages
-
SGI
1 Pages
-
Venturirohr
4 Pages
-
Venturi-flowmeter EVR2000
1 Pages
-
MR 90
4 Pages
-
TOUCHSCREEN - display
1 Pages
-
AD96TF - digital indicator
1 Pages
-
AFD / AKD - analog indicator
1 Pages
-
About us and our products
24 Pages
Archived catalogs
-
MID
1 Pages
-
MINI90
1 Pages
-
RGF
1 Pages
-
WBV
1 Pages
-
DS85-P
2 Pages
-
DS85
1 Pages
-
DPCS200
2 Pages
-
WR 90
1 Pages
-
AQD / AQ72
1 Pages
-
TOUCHSCREEN
1 Pages
-
AD-72P
1 Pages
-
AD96TF
1 Pages
-
AD 72P-ST
1 Pages
-
AD 72P-WT
1 Pages
-
AD 96TF
1 Pages
-
AFD
1 Pages
-
AFD-TK
1 Pages
-
CM2
1 Pages
-
ice thickness controler EDR
1 Pages
-
O2T
1 Pages
-
WT225, VT225, WT225
1 Pages
-
ST225
1 Pages
-
SP225
1 Pages
-
TR225
1 Pages
-
GS225
1 Pages
-
GIV
1 Pages
-
Flora II
1 Pages
-
AF 1
1 Pages
-
catalogue
80 Pages