data sheets measuring grid - SGI - 1 Pages

Add to MyDirectIndustry favorites
data sheets measuring grid - SGI

Catalog excerpts

MEASURING GRID SGIfor air measurement in pipelines □ For measure speed after the dynamic pressure method □ Arrangement of several cylinder pitot tube □ Central tubes with laterally attached probe tubes □ Material brass (up to 100 °C) or stainless steel (up to 450 °C) □ Pressure connection 6mm □ Mounting parts available The SGI is a special lattice arrangement of a plurality of cylinder probes, which are distributed over a cross section that can be at different flow distribution in a pipe found in a canal or a mean flow. The probe is connected to the grid and each pipe or channel dimensions can be customized. It can be made for the edge or square channel cross-sections. For larger sizes is usually required a thrust bearing. Specifications Construction:    central tubes with laterally attached probe tubes Pressure taps:    6 mm 0 plastic tubing for connection Grand calculation for cylinder position sensor and sensor grids: Comment: The use of the differential Peritact 80 (± 1.5%) with the smallest range of 0...1 mbar results as a range for the lowest velocity 0...8 m / s. The transmitter MKM (± 0.2%) and 2000-K10 Peritact (± 1%) with the smallest ranking of 0... 0.1 mbar as a result, the lowest range for velocity 0...3 m/s. Larger ranges are possible by adjusting the transmitter. w = velocity in m/s Ap = differential pressure in mbar p = density at actual conditions in kg/m3 C = coefficient for cylindrical probe = 2 for Prandtl-pitot tube = 1 Measuring grid SGI Dimensions    material Other dimensions on request. Camp GL-SGI for fixing the measuring grid FLOW    Date: 13.02.17 Arthur Grillo GmbH • Am Sandbach 7 • 40878 Ratingen • phone 0 21 02 - 47 10 22 • fax 0 21 02 - 47 58 82 www.grillo-messgeraete.de/en • Email: info@grillo-messgeraete.de • web shop: www.sensor-store.d

 Open the catalog to page 1

All Arthur Grillo GmbH catalogs and technical brochures

  1. data sheet mkm

    1 Pages

  2. data sheet AF1

    1 Pages

  3. data sheet O2T

    1 Pages

  4. data sheet ETF

    1 Pages

  5. data sheet edr

    1 Pages

  6. data sheet wbv

    1 Pages

  7. data sheet mbz

    1 Pages

  8. data sheet CM2

    1 Pages

  9. data sheet MID

    1 Pages

  10. SPECIAL

    18 Pages

  11. TEMPERATURE

    20 Pages

  12. Display

    14 Pages

  13. HUMIDITY

    21 Pages

  14. PRESSURE

    35 Pages

  15. data sheet

    2 Pages

  16. data sheet DS85

    2 Pages

  17. data sheet DA85

    1 Pages

  18. data sheet

    2 Pages

  19. data sheet DS85

    2 Pages

  20. SHT11/15

    1 Pages

  21. Orifice plate

    3 Pages

  22. SGI

    1 Pages

  23. Venturirohr

    4 Pages

  24. MR 90

    4 Pages

Archived catalogs

  1. MID

    1 Pages

  2. MINI90

    1 Pages

  3. RGF

    1 Pages

  4. WBV

    1 Pages

  5. DS85-P

    2 Pages

  6. DS85

    1 Pages

  7. DPCS200

    2 Pages

  8. WR 90

    1 Pages

  9. AQD / AQ72

    1 Pages

  10. TOUCHSCREEN

    1 Pages

  11. AD-72P

    1 Pages

  12. AD96TF

    1 Pages

  13. AD 72P-ST

    1 Pages

  14. AD 72P-WT

    1 Pages

  15. AD 96TF

    1 Pages

  16. AFD

    1 Pages

  17. AFD-TK

    1 Pages

  18. CM2

    1 Pages

  19. O2T

    1 Pages

  20. ST225

    1 Pages

  21. SP225

    1 Pages

  22. TR225

    1 Pages

  23. GS225

    1 Pages

  24. GIV

    1 Pages

  25. Flora II

    1 Pages

  26. AF 1

    1 Pages

  27. catalogue

    80 Pages