data sheet peritact 80-1

Arthur Grillo DIFFERENTIAL PRESSURE GAUGE PERITACT 80 □ Diaphragm element □ Smallest measuring range 0...50 Pa □ Analogue output 0...10 V or 4...20 mA □ Large analogue scale □ Min. and max. contact possible □ Also two-wire transmitter MZP80 available □ Protection class IP 65 Manometer with diaphragm element for indication of pressure, under pressure or differential pressure of non aggressive gas. For flow measurements, by the differential pressure method, versions are available with a square graduation. Overload protection: Static pressure: Zero drift: Sum of linearity and hysteresis: Temperature drift zero point: Temperature drift measuring range: Operating mode: Measuring medium: Measuring principle: Measuring unit: Smallest measuring range: Largest measuring range: Measuring range: Measuring range selection: Ambient temperature: Storage temperature: Setpoint setting: Contact load: PERFORMANCE: min. up to 10-times the measuring range max. 0.2 bar ACCURACY/ERROR LIMIT: ± 0.75 % ± 1.5 % of measuring range ± 0.3 % / 10 K ± 0.2 % / 10 K TECHNICAL SPECIFICATIONS: Measuring mode Air or non-aggressive gases diaphragm measuring system Pa 0...50 Pa (0.5 mbar) 0...6000 Pa (60 mbar) 0.50 Pa (0.5 mbar), 0.100 Pa (1 mbar), 0...200 Pa (2 mbar), 0.400 Pa (4 mbar), 0.500 Pa (5 mbar), 0...1000 Pa (10 mbar), 0...2000 Pa (20 mbar), 0.4000 Pa (40 mbar), 0.5000 Pa (50 mbar), 0.6000 Pa (60 mbar) factory preset -10...+50 °C -25...+60 °C 2 Setpoint pointer adjustable over the full scale range, per limit value 1 Output relay with potential-free change-over contact 250 Vac, 6A, induction-free load Date: 13.02.17 PRESSURE Housing: Dimensions: Weight: Protection class: Display: Electrical connections: Pressure connections: Power supply: Output: PHYSICALLY: ABS, transparent cover 134 x 170 x 137 mm (w x h x d) approx. 1500 g IP65 according EN 60529 pointer display with scale screw terminal hose connections 5 mm 0 ELECKTRONIC: 230 Vac, 24 Vac or 24 Vdc, @ two-wire circuit 13...30 Vdc via power supply 0/4...20 mA or 0...10 V or 4...20 mA in two-wire circuit CONFORMITY: EMC: EN 61000-6-2, EN 61000-6-3, CE-mark RoHS: according RoHS-directive 2011/65/EU Arthur Grillo GmbH • Am Sandbach 7 • 40878 Ratingen • phone 0 21 02 - 47 10 22 • fax 0 21 02 - 47 58 82 www.grillo-messgeraete.de/en • Email: [email protected] • web shop: www.sensor-store.de

 Open the catalog to page 1
data sheet peritact 80-2

input output Item no. Differential pressure gauge PERITACT 80 2415 Wall mount device Measurement range: Customer-specific presetting required! Differential pressure gauge PERITACT 80 with min. and max. contacts 2425 Supply voltage 230 Vac or 24 Vac or 24 Vdc, wall mount device Measurement range & supply Voltage: Customer-specific presetting required! Differential pressure guuge PERITACT 80 with electrical output signal 2435 0/4...20 mA or 0...10 V, supply voltage 230 Vac or 24 Vac, wall mount device Measurement range & signal output: Customer-specific presetting required! Differential...

 Open the catalog to page 2

All Arthur Grillo GmbH catalogs and technical brochures

  1. SPECIAL

    18  Pages

  2. TEMPERATURE

    20  Pages

  3. Display

    14  Pages

  4. HUMIDITY

    21  Pages

  5. PRESSURE

    35  Pages

  6. WR 200-F

    2  Pages

  7. SHT11/15

    1  Page

  8. Orifice plate

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.