data sheet MINI90P-1

MULTI RANGE TRANSMITTER MINI90-P □ Resistant element Pt100 class A DIN EN 60751 □ 8 calibrated measuring ranges selectable via DIP-switches □ Sensor tube 9 mm stainless steel 1.4571 □ Analogue output 4...20 mA □ Plastic housing with protection class IP 65 The MINI90-P series is designed for temperature measurement in pipes or channels. Three versions are available: • Straight sensor tube for use in protective sleeves • Perforated sensor tube tip for measurements in air ducts • Sensor tube with G1 / 2A screw for measurements in liquids In the G1 / 2A version of the measuring insert, together with electronics can be replaced without that the sensor tube must be screwed out of the pipeline. Measurement tolerance: Long-term stability: Operating mode: Measuring medium: Measuring principle: Measuring unit: Max. temperature: Measuring ranges: Ambient temperature: Protective tube: Connection head: Sleeve: Protection class: Electrical connection: Installation: Weight: Output: Supply voltage: EMC: RoHS: ACCURACY/ ERROR LIMIT: < 0,25 % ± 0,15 °C Max. R0-Drift 0,05 % / year TECHNICAL SPECIFICATIONS: Measuring mode Temperature Pt100 class A according DIN EN 60751 °C Max. 400 °C 8 calibrated measuring ranges can be selected via DIP switches -10...+70 °C PHYSICALLY: 9 mm stainless steel, w. 1.4571 Plastic ABS, light gray Screw-in protective sleeve SHS-M90, brass, brazed; Welding protection sleeve SHE-M90, St37 PN40 IP 65 according to EN 60529 Two-wire, three-wire technology Mounting flange Approx. 250 g ELECTRONIC: 13 ... 30 Vdc, any polarity or 24 Vdc or 24 Vac, ± 25% 0...10 V or 4...20 mA CONFORMITY: EN 61000-6-2, EN 61000-6-3, CE-mark according RoHS-directive 2011/65/EU Measurement group 2 Solution 0.4 °C DIP1 1. 0...400 °C Measurement range: Measurement group 1 Solution 0.2 °C Multiple range transmitter MINI 90-P sensor tube smooth, 8 selectable range 2-wire technology, output: 4...20 mA, Measurement range: Customer-specific presetting required! 7123 Multiple range transmitter MINI 90-P sensor tube perforated, 8 selectable range 2-wire technology, output: 4...20 mA, Measurement range: Customer-specific presetting required! 7124 Multiple range transmitter MINI 90-P sensor tube with G1/2A, 8 selectable range 2-wire technology, output: 4...20 mA, Measurement range: Customer-specific presetting required! 7129 Mounting flange MF-M90 for air ducts 71201 Screw-in sleeve SHS-M90, brass, brazed 71202 Special length L1 / L2 Customer-specific presetting required! 71204

 Open the catalog to page 1

All Arthur Grillo GmbH catalogs and technical brochures

  1. SPECIAL

    18  Pages

  2. TEMPERATURE

    20  Pages

  3. Display

    14  Pages

  4. HUMIDITY

    21  Pages

  5. PRESSURE

    35  Pages

  6. WR 200-F

    2  Pages

  7. SHT11/15

    1  Page

  8. Orifice plate

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.