Catalog excerpts

MULTI RANGE TRANSMITTER MINI90-P □ Resistant element Pt100 class A DIN EN 60751 □ 8 calibrated measuring ranges selectable via DIP-switches □ Sensor tube 9 mm stainless steel 1.4571 □ Analogue output 4...20 mA □ Plastic housing with protection class IP 65 The MINI90-P series is designed for temperature measurement in pipes or channels. Three versions are available: • Straight sensor tube for use in protective sleeves • Perforated sensor tube tip for measurements in air ducts • Sensor tube with G1 / 2A screw for measurements in liquids In the G1 / 2A version of the measuring insert, together with electronics can be replaced without that the sensor tube must be screwed out of the pipeline. Measurement tolerance: Long-term stability: Operating mode: Measuring medium: Measuring principle: Measuring unit: Max. temperature: Measuring ranges: Ambient temperature: Protective tube: Connection head: Sleeve: Protection class: Electrical connection: Installation: Weight: Output: Supply voltage: EMC: RoHS: ACCURACY/ ERROR LIMIT: < 0,25 % ± 0,15 °C Max. R0-Drift 0,05 % / year TECHNICAL SPECIFICATIONS: Measuring mode Temperature Pt100 class A according DIN EN 60751 °C Max. 400 °C 8 calibrated measuring ranges can be selected via DIP switches -10...+70 °C PHYSICALLY: 9 mm stainless steel, w. 1.4571 Plastic ABS, light gray Screw-in protective sleeve SHS-M90, brass, brazed; Welding protection sleeve SHE-M90, St37 PN40 IP 65 according to EN 60529 Two-wire, three-wire technology Mounting flange Approx. 250 g ELECTRONIC: 13 ... 30 Vdc, any polarity or 24 Vdc or 24 Vac, ± 25% 0...10 V or 4...20 mA CONFORMITY: EN 61000-6-2, EN 61000-6-3, CE-mark according RoHS-directive 2011/65/EU Measurement group 2 Solution 0.4 °C DIP1 1. 0...400 °C Measurement range: Measurement group 1 Solution 0.2 °C Multiple range transmitter MINI 90-P sensor tube smooth, 8 selectable range 2-wire technology, output: 4...20 mA, Measurement range: Customer-specific presetting required! 7123 Multiple range transmitter MINI 90-P sensor tube perforated, 8 selectable range 2-wire technology, output: 4...20 mA, Measurement range: Customer-specific presetting required! 7124 Multiple range transmitter MINI 90-P sensor tube with G1/2A, 8 selectable range 2-wire technology, output: 4...20 mA, Measurement range: Customer-specific presetting required! 7129 Mounting flange MF-M90 for air ducts 71201 Screw-in sleeve SHS-M90, brass, brazed 71202 Special length L1 / L2 Customer-specific presetting required! 71204
Open the catalog to page 1All Arthur Grillo GmbH catalogs and technical brochures
-
data_sheets_kf_etf_atf_af
1 Pages
-
Data_sheet_gpm
1 Pages
-
data sheet DPC200-AC
2 Pages
-
data sheet DPC200-MOD
2 Pages
-
data sheet mkm
1 Pages
-
data sheet room sensor
1 Pages
-
data sheet venturi
4 Pages
-
data sheet AF1
1 Pages
-
data sheet PFT22
2 Pages
-
data sheet O2T
1 Pages
-
data sheet ETF
1 Pages
-
data sheet floraII
1 Pages
-
data sheet PU21 / PI21
1 Pages
-
data sheet edr
1 Pages
-
data sheet thermocouples
2 Pages
-
data sheet wbv
1 Pages
-
data sheet PFT28KA
2 Pages
-
data sheet AD72P
1 Pages
-
data sheet GS225
1 Pages
-
data sheet mini72
1 Pages
-
data sheet mbz
1 Pages
-
Datenblatt PFT28
2 Pages
-
data sheet PFT28
2 Pages
-
data sheet CM2
1 Pages
-
DIFFERENTIAL PRESSURE SENSOR
2 Pages
-
data sheet PFT25 series
2 Pages
-
data sheet AQD / AQ72
1 Pages
-
data sheet DA2000-S
2 Pages
-
data sheet touchscreen
1 Pages
-
data sheet WR200D
2 Pages
-
data sheet MID
1 Pages
-
SPECIAL
18 Pages
-
TEMPERATURE
20 Pages
-
Display
14 Pages
-
HUMIDITY
21 Pages
-
PRESSURE
35 Pages
-
DA2000 protected serie
2 Pages
-
data sheet MTA90
1 Pages
-
data sheet MINI90
1 Pages
-
WR 200-F
2 Pages
-
data sheet DS200
2 Pages
-
data sheet DPC200
2 Pages
-
data sheet DS85
2 Pages
-
data sheet DPC310
2 Pages
-
data sheet peritact 80
2 Pages
-
data sheet DA2000
3 Pages
-
data sheet DPC200R
2 Pages
-
data sheet Peritact2000
3 Pages
-
data sheet DA85
1 Pages
-
data sheet PFT30
2 Pages
-
data sheet DS85PE
2 Pages
-
O2T - flue gas tester for O2
1 Pages
-
MULTIPLE-SUPPLY UNIT SP225
1 Pages
-
ISOLATION AMPLIFIER TR225
1 Pages
-
LIMIT SWITCH GS225
1 Pages
-
CLIMATE TRANSMITTER PFT30
2 Pages
-
CLIMATE TRANSMITTER PFT28Ka
2 Pages
-
Process transmitter
1 Pages
-
DS - pressure switch
1 Pages
-
GPM - prozess transmitter
1 Pages
-
MINI90 - transmitter
1 Pages
-
MINI72 / MTA90 - transmitter
1 Pages
-
PTF28 - climate transmitter
2 Pages
-
SHT11/15
1 Pages
-
Orifice plate
3 Pages
-
product category - pressure
33 Pages
-
product category - temperature
17 Pages
-
product category - humidity
15 Pages
-
product category - flow
30 Pages
-
product category - special
16 Pages
-
product category - display
12 Pages
-
product catalog low resolution
91 Pages
-
cylinder pitot tube MBZ
1 Pages
-
SGI
1 Pages
-
Venturirohr
4 Pages
-
Venturi-flowmeter EVR2000
1 Pages
-
MR 90
4 Pages
-
TOUCHSCREEN - display
1 Pages
-
AD96TF - digital indicator
1 Pages
-
AFD / AKD - analog indicator
1 Pages
-
About us and our products
24 Pages
Archived catalogs
-
MID
1 Pages
-
MINI90
1 Pages
-
RGF
1 Pages
-
WBV
1 Pages
-
DS85-P
2 Pages
-
DS85
1 Pages
-
DPCS200
2 Pages
-
WR 90
1 Pages
-
AQD / AQ72
1 Pages
-
TOUCHSCREEN
1 Pages
-
AD-72P
1 Pages
-
AD96TF
1 Pages
-
AD 72P-ST
1 Pages
-
AD 72P-WT
1 Pages
-
AD 96TF
1 Pages
-
AFD
1 Pages
-
AFD-TK
1 Pages
-
CM2
1 Pages
-
ice thickness controler EDR
1 Pages
-
O2T
1 Pages
-
WT225, VT225, WT225
1 Pages
-
ST225
1 Pages
-
SP225
1 Pages
-
TR225
1 Pages
-
GS225
1 Pages
-
GIV
1 Pages
-
Flora II
1 Pages
-
AF 1
1 Pages
-
catalogue
80 Pages