data sheet DPC200-AC
2Pages

{{requestButtons}}

Catalog excerpts

data sheet DPC200-AC - 1

DIFFERENTIAL PRESSURE / VOLUME FLOW CONTROLLER DPC200-AC Electromechanical diaphragm measuring system Measuring range from 0...50 Pa (0.5 mbar) up to 0...6000 Pa (60 mbar) Alphanumeric LCD-display Analog output 0...10 V Selectable measurements (differential pressure or volume flow) Selectable units (metric or imperial) Adjustable k-factor for volume flow calculation Controlling mode or measuring mode selectable Measuring mode with adjustable limit value Control mode with adjustable: - 2 setpoints - PI parameters for PI algorithm - maximum output voltage Supply voltage 90...260 Vac (50 / 60 Hz) Compact plastic housing IP 54 The DPCs are electromechanical differential pressure / volume flow controllers with a diaphragm measuring system and a comprehensive evaluation software. They are used to measure and control the smallest differential pressures of non-aggressive gases, in particular of air. Their optimal application area can be found in the field of climatic technology for controlling fans, room pressure monitoring or filter control. The devices allow controlling of air flow or keeping up a constant pressure in a closed environment. In addition to the analog output, an additional alarm output (open collector, max. 30 V / 30 mA or relay 250 Vac / 10 A) is available for limit monitoring or filter monitoring. The device provides a radiated output signal as a volumetric flow sensor. In the case of the pressure or volume flow control, the output signal is the manipulated variable of the PI control. Connection diagram DPC200-AC power supply voltage 1 protective earth Alarm output high ohm: alarm off low ohm: alarm on maximum customer circuit 30 Vdc / 30 mA dry contact open: setpoint 1 close: setpoint 2

Open the catalog to page 1
data sheet DPC200-AC - 2

DIFFERENTIAL PRESSURE / VOLUME FLOW CONTROLLER DPC200-AC Overpressure protection: Static pressure: Zero point calibration: Reaction time: PERFORMANCE: 0.2 bar max. 0.2 bar Adjustable by REEDcontact, no cyclic zero-point calibration required direct Zero drift: Sum of linearity and hysteresis: Temperature drift zero point: Temperature drift measuring range: Operating mode: Measuring medium: Measuring principle: Measuring unit: Smallest measuring range: Largest measuring range: Measuring range: Measuring range selection: Adjustable controlling parameters: Characteristic: Ambient temperature:...

Open the catalog to page 2

All Arthur Grillo GmbH catalogs and technical brochures

  1. SPECIAL

    18 Pages

  2. TEMPERATURE

    20 Pages

  3. Display

    14 Pages

  4. HUMIDITY

    21 Pages

  5. PRESSURE

    35 Pages

  6. WR 200-F

    2 Pages

  7. SHT11/15

    1 Pages

  8. SGI

    1 Pages

  9. Venturirohr

    4 Pages

  10. MR 90

    4 Pages

Archived catalogs

  1. MID

    1 Pages

  2. MINI90

    1 Pages

  3. RGF

    1 Pages

  4. WBV

    1 Pages

  5. DS85-P

    2 Pages

  6. DS85

    1 Pages

  7. DPCS200

    2 Pages

  8. WR 90

    1 Pages

  9. AQD / AQ72

    1 Pages

  10. TOUCHSCREEN

    1 Pages

  11. AD-72P

    1 Pages

  12. AD96TF

    1 Pages

  13. AD 72P-ST

    1 Pages

  14. AD 72P-WT

    1 Pages

  15. AD 96TF

    1 Pages

  16. AFD

    1 Pages

  17. AFD-TK

    1 Pages

  18. CM2

    1 Pages

  19. O2T

    1 Pages

  20. ST225

    1 Pages

  21. SP225

    1 Pages

  22. TR225

    1 Pages

  23. GS225

    1 Pages

  24. GIV

    1 Pages

  25. Flora II

    1 Pages

  26. AF 1

    1 Pages

  27. catalogue

    80 Pages