video corpo

catalogue

catalogue
1 / 80 PagesView full catalog

catalogue

Product catalog summary
Low-Pressure Instruments Overview
This section describes various low-pressure instruments for measuring differential pressure in non-corrosive gases, with ranges from 0...10 Pa to 0...10,000 Pa. Options include analog and digital displays, analog output signals, and switch contacts.
Differential Pressure Indicator Peritact 80
- Diaphragm element with a range starting at 0...50 Pa.
- Analog outputs: 0...10 V, 0...20 mA, or 4...20 mA.
- Supply voltage: 230 Vac, 24 Vac, or 24 Vdc.
- Wall-mounted with IP 65 protection, suitable for non-aggressive gases.
Low Pressure Transmitter Peritact 2000
- Diaphragm element with a range from 0...50 Pa.
- Analog outputs: 0...10 V, 0...20 mA, or 4...20 mA.
- Digital display with 3 1/2 digits.
- Wall-mounted with IP 65 protection.
Low Pressure Transmitter Peritact 2000-K
- Diaphragm element with a range starting at 0...50 Pa.
- Dual analog outputs and two switching contacts.
- Alphanumeric LCD display.
- Suitable for air-flow measurement.
Low Pressure Transmitter Peritact 2000-K10
- Dynamic micro flow sensor with a range from 0...10 Pa.
- Dual analog outputs and two contact outputs.
- Illuminated LCD display.
- Wall-mounted with IP 65 protection.
Differential Pressure Transmitter MKM
- High precision with a diaphragm element.
- Range starts at 0...10 Pa.
- Analog outputs: 0...10 V or 4...20 mA.
- Suitable for non-aggressive gases.
General Specifications
- Designed for non-aggressive gases with various protection classes and mounting options.
- Range of outputs and supply voltages available.
- Accessories and extra charges for non-standard ranges and mounting options.
Specifications Overview
The document outlines specifications for pressure transmitters and differential pressure indicators, including ranges, overpressure protection, static pressure, output characteristics, supply voltage, and more.
Pressure Transmitters
- MKM series ranges from 0...10 Pa to 0...6000 Pa.
- Linear and square-rooted characteristics.
- Accessories include calibrating weights and throttle nozzles.
Differential Pressure Indicators
- DA 2000 series with analog outputs and pressure switches.
- Ranges from 0...100 Pa to 0...5000 Pa.
Pressure Switches
- DS series adjustable for non-aggressive gases, ranges from 40...200 Pa.
Differential Pressure Sensors
- DS 85 series ranges from 0...50 Pa to 0...10000 Pa, with analog outputs and optional LCD displays.
Selectable Range Sensors
- DS 85-P series with selectable ranges via DIP-switch, covering 50 Pa to 6000 Pa.
General Information
- Includes order numbers, pricing details, and contact information for Arthur Grillo GmbH.
Differential Pressure Sensor DS 200
- Designed for small differential pressures in air conditioning systems.
- Silicon membrane and measuring spring.
- Four calibrated ranges selectable via DIP-switch.
Differential Pressure Controller DPC 200
- Measures and controls small differential pressures.
- PID algorithm in control mode.
- Alphanumeric LCD and analog output of 0...10 V.
Venturi Tube
- Used for flow metering in ventilation systems.
- Made from plastic PPs, designed according to DIN EN ISO 5167 standards.
Cylinder Pitot Tube MBZ
- Primary element for velocity measurement using the dynamic pressure method.
- Available in brass or stainless steel.
Overview
The document provides technical specifications for electronic components like mounting rails, isolation amplifiers, limit switches, and temperature transmitters.
Mounting Rail
- Standard 35 mm mounting rail according to EN50022.
- Features electronic fusing for short circuits.
Isolation Amplifier TR 225
- Provides galvanic isolation between input, output, and supply voltage.
Limit Switch GS 225
- Monitors electrical current signals with adjustable hysteresis and time delay.
Transmitter MINI 90
- Temperature transmitter with Pt100 sensor according to DIN 43760.
Transmitter MINI 72 / MTA 90
- Room and outdoor temperature transmitters with Pt100 sensors.
Multiple-range Transmitter MINI 90-P
- Temperature transmitter with 8 selectable ranges via DIP-switch.
Multiple-range Transmitter MTA 90-P
- Designed for moist environments or outdoors with 4 selectable ranges.
Key Specifications
- Supply voltage varies across devices, typically around 18 Vdc.
- Protection classes range from IP 20 to IP 65.
Conclusion
The document provides comprehensive technical details for a range of electronic components, focusing on their specifications, applications, and compliance with industry standards.
Overview
The document provides detailed specifications and functionalities of various climate and humidity transmitters manufactured by Arthur Grillo GmbH.
Two-Wire Transmitter
- Converts non-electrical quantities like temperature and humidity into a 4...20 mA electrical signal.
Three-Wire Transmitter
- Provides an output signal of 0...10 Vdc or 0...20 Vdc.
Single-Chip Sensor
- Integrates a capacitive sensor, amplification, A/D transformer, and calibration data.
Transmitter PFT 22
- Measures relative humidity and temperature, offering digital signal transmission.
Climate Transmitter PFT 25
- Converts measured temperature and humidity into climatic values like dew point and enthalpy.
Climate Transmitter PFT 28
- Includes an alphanumeric LCD display for direct value indication.
Specifications and Features
- Detailed specifications for each transmitter model, including accuracy, response time, and output options.
Overview
The document provides detailed specifications and descriptions of various climate and flow measurement equipment offered by Arthur Grillo GmbH.
Climate Transmitters
- PFT 28 series designed for measuring climatic values in air conditioning ducts.
Measuring Indicator Flora II
- Designed for climate monitoring in environments like greenhouses.
Flow Measurement Equipment
- Includes orifice plates for differential pressure flow measurement of liquids, gases, or vapors.
Accessories
- Various accessories for flow measurement are available.
Differential Pressure Transmitter GPM
- Used for measuring pressure differences in liquids, gases, or vapors.
Specifications and Features
- Detailed specifications for differential pressure transmitters and flow measurement equipment.
Product Range
- Lists several models of differential pressure transmitters with varying pressure ranges and prices.
Flow Measurement with Orifice Plates
- Describes the connection of measuring apertures with differential pressure measurements for liquids and gases.
Heat Quantity Measurement
- Outlines the process for measuring heat quantity in liquids using orifice plates and magnetic-inductive transmitters.
Heat Energy Meter WR 200-F
- Specifications of the WR 200-F heat energy meter for detecting heat energy in closed systems.
Magnetic Inductive Flowmeter MID
- Advantages of using the MID flowmeter, including linear output signals and low pressure loss.
Steam Heat Quantity Measurement
- Details on measuring heat quantity with steam as the heat transfer medium.
Overview
The document provides detailed specifications and functionalities of the Wärmezähler WR 200-D, a heat energy meter designed for steam and heating systems.
Specifications
- Equipped with two Pt100 inputs for steam and condensate temperature measurement.
Functionalities
- Calculates heat output using a specific formula involving steam flow, heat of vaporization, and temperature differences.
Installation and Accessories
- Can be mounted on a DIN rail or wall, with accessories available for panel mounting.
Additional Products
- Describes other measurement devices such as analog and LED indicators.
Special Applications
- Custom solutions for specific measurement challenges, including CO2 monitoring using the CM2 device.
Contractual Obligations and Rights
  • Payment and Contract Termination: The seller reserves the right to withdraw from the contract if the buyer defaults on payment.
  • Buyer's Responsibilities: The buyer must maintain and insure the purchased object against damage or loss.
  • Third-Party Claims: The buyer must inform the seller immediately of any third-party claims.
  • Resale and Assignment of Claims: The buyer can resell the object but must assign claims from resale to the seller.
  • Processing and Co-ownership: Any processing or alteration of the object by the buyer is done on behalf of the seller.
  • Real Estate Connection: Claims against third parties from connecting the object to real estate are assigned to the seller.
  • Release of Securities: The seller will release securities if their value exceeds the secured claims by more than 20%.
Legal and Fulfillment Terms
  • Jurisdiction: Legal actions are to be filed at the seller's business location in Ratingen.
  • Place of Fulfillment: The seller's business location in Ratingen is the default place of fulfillment.
  • Applicable Terms: The "General Delivery Terms for the Products and Services of the Electrical Industry" apply.
  • Severability Clause: If any provision is ineffective, it will be replaced by a valid provision that closely aligns with the original intent.
See more

Catalog excerpts

catalogue-1

LOW-PRESSURE INSTRUMENTS Page 5 - 26 Differential pressure indicator Peritact 80 6-7 Low pressure transmitter Peritact 2000 8 Low pressure transmitter Peritact 2000-K 9 Low pressure transmitter Peritact 2000-K10 10 Differential pressure transmitter MKM 11 Differential pressure indicator DA 2000 12-13 Differential pressure indicator DA 85 14 Differential pressure sensor DS 85 16-17 Differential pressure sensor with selectable ranges DS 85-P 18-19 Differential pressure sensor with selectable ranges DS 200 20 - 21 Differential pressure controller DPC 200 22 - 23 Cylinder pitot tube 27 Supply unit and supply converter ST 225 36 Multiple-range transmitter MINI 90-P 42 Two-wire and three-wire transmitter - Information 44 Transmitter for relative humidity and temperature PFT 22 46 - 47 Transmitter for relative humidity and temperature PFT 22H/PFT 25H 52 Measuring indicator flora II 53

 Open the catalog to page 1
catalogue-2

FLOW MEASUREMENT EQUIPMENT Page 54 - 69 Accessories flow measurement with orifice 58 Flow measurement with orifice (fluids - steam) 60 Flow measurement with orifice (steam) 61 Heat quantity measurement (fluids) with orifice plates 62 Heat quantity measurement (water) with MID 63 Heat energy meter WR 200-F for liquid heat carriers 64 - 65 Magnetic inductive flowmeter MID 66 Heat quantity measurement (steam) 67 Heat energy meter WR 200-D for steam 68 - 69 MEASURED VALUE REPRESENTATION Page 70 - 73 SPECIAL APPLICATIONS Page 74 - 79

 Open the catalog to page 2
catalogue-3

Low-pressure instruments It can be detected all non-corrosive gases with these membrane instruments. Depending on the application, we offer devices with analog or digital display with analog output signals or to switch contacts. Low-pressure instruments Our low pressure area consists of display devices, sensors and transducers for differential pressure in the ranges 0...10 Pa to 0...10.000 Pa capture.

 Open the catalog to page 3
catalogue-4

Low-pressure instruments Differential pressure indicator Peritact 80 Diaphragm element Smallest measuring range 0...50 Pa Analog output 0...10 V, 0...20 mA or 4...20 mA Large analogue seale Supply voltage 230 Vac, 24 Vac or 24 Vdc Min or Max-contact Also two-wire transmitter MZP 80 Wall-mounted device IP 65 Indicator with lead diaphragm element for indication, signaling and transmitting pressure, underpressure or differential pressure of nonaggressive gases. Devices for measuring flow in accordance with the active pressure procedure are available with quadratic scale. physical Dimensions Specifications...

 Open the catalog to page 4
catalogue-5

Differential pressure indicator Peritact 80 Low-pressure instruments wall mounting range: -please specifyIndicator Peritact 80 with min.- and max.-contact supply voltage 230 Vac, 24 Vac, wall mounting range: -please specifyIndicator Peritact 80 with electrical output signal 0/4...20 mA or 0...10 V, voltage 230 Vac or 24 Vac, wall constuction case range: -please specifyIndicator Peritact 80 with electrical output signal as wel min.- and max.-contact 0/4...20 mA or 0...10 V supply voltage 230 Vac or 24 Vac, wall mounting range: -please specifyTwo-Wire transmitter MZP 80 output 4...20 mA, supply...

 Open the catalog to page 5
catalogue-6

Low-pressure instruments Low pressure transmitter Peritact 2000 Diaphragm element Smallest measuring range 0...50 Pa Analog output 0...10 V, 0...20 mA or 4...20 mA Digital display 3 1/2-digits, character height 13 mm Supply voltage 230 Vac, 24 Vac or 24 Vdc Wall mounting case IP 65 Two-wire system Peritact 2000-2L Measuring device with diaphragm element for indicating, controlling and transmitting of pressure, draught and differential pressure of nonaggressive gases. physical dimensions Specifications lowest span: largest span: adjusted span: overpressure protection: static pressure: pressure...

 Open the catalog to page 6
catalogue-7

Low pressure transmitter Peritact 2000-K Diaphragm element Smallest measuring range 0...50 Pa 2 analog output 0/2...10 V and 0/4...20 mA 2 switching contacts with pins 250 Vac, 8 A Switching function min. or max. Alphanumeric LCD display with 4 at 20 characters each Supply voltage 230 Vac, 24 Vac or 24 Vdc Wall mounting case IP 65 Measuring device with diaphragm element for indicating, controlling and transmitting of pressure, draught and differential pressure of nonaggressive gases. Also for air-flow measuring in accordance to effective head- or pressure head procedure with characteristic square...

 Open the catalog to page 7
catalogue-8

Low-pressure instruments Low pressure transmitter Peritact 2000-K10 Dynamic micro flow sensor Smallest measuring range 0...10 Pa 2 analog outputs 0/2...10 V and 0/4...20 mA 2 contact outputs with change-over contacts 250 Vac, 8 A Switching function min. or max. Illuminated LCD-indicator with 4 lines at 20 characters each Supply voltage 230 Vac, 24 Vac or 24 Vdc Wall mounting case IP 65 Measuring device with micro flow sensor for indicating, controlling and transmitting of pressure, underpressure or differential pressure of nonaggressive gases. Because of the measuring principle, the device is...

 Open the catalog to page 8
catalogue-9

Differential pressure transmitter MKM Diaphragm element High precision transmitter Smallest measuring range 0...10 Pa Analogoutput 0...10 V or 4...20 mA Supply voltage 230 Vac or 24 Vac Precision-transmitter with lead diaphragm element for transmitting of pressure, draught and differential pressure of non-aggressive gases. The transmitter is especially designed for lowest ranges up to 10 Pa. It works in accordance to the power compensation principal. Calibration of the transmitter can be examined easily by imposing suitable weights. The transmitter is particularly suitable for the smallest span...

 Open the catalog to page 9
catalogue-10

Low-pressure instruments Differential pressure indicator DA 2000 Diaphragm element Smallest range 0...100 Pa Analog output 0...10 V or 4...20 mA possible Wide analog display (270°) Combination with a pressure switch (DA 2000-K) Scaling in m³/h possible Indicator with lead diaphragm element for indication of pressure, underpressure or differential pressure of non-aggressive gases. Supply of indicator with accessories for mounting in front of or behind a panel or for wall mounting. Options: Two limit value pointers red or green. physical dimensions wall constuction Indicator with analog output...

 Open the catalog to page 10

All Arthur Grillo GmbH catalogs and technical brochures

  1. SPECIAL

    18  Pages

  2. TEMPERATURE

    20  Pages

  3. Display

    14  Pages

  4. HUMIDITY

    21  Pages

  5. PRESSURE

    35  Pages

  6. WR 200-F

    2  Pages

  7. SHT11/15

    1  Page

  8. Orifice plate

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.