1. Catalogs
  2. Arteco Motion Tech
  3. I/O CANOpen module
cad

I/O CANOpen module

I/O CANOpen module

I/O CANOpen module

Product catalog summary
Fieldbus: The device supports CanBus with CANOpen 2.0b standard in slave mode.
Power Supply Requirements: The power supply voltage required is 24 Vdc with a tolerance of ±20%.
Digital Input & Output Configuration:
  • 32 digital inputs: Opto-isolated, 24Vdc PNP.
  • 64 digital inputs: Opto-isolated, 24Vdc PNP.
  • 16 digital inputs + 16 digital outputs: Opto-isolated, 24Vdc PNP, 1.8 Amp/output, with a maximum of 4.4 Amps on each group of 4 outputs. Protected against short-circuits, over-current, overheating, over-voltage, and power voltage inversion.
  • 32 digital inputs + 32 digital outputs: Same specifications as above.
  • 16 digital inputs + 48 digital outputs: Same specifications as above.
  • 48 digital inputs + 16 digital outputs: Same specifications as above.
General Features:
  • Field Connections: Via separable terminal strip and 9-pole Canon Sub-D connectors.
  • Case: Screened with dimensions of 175mm x 108mm x 75mm.
  • Assembly: Designed for DIN rail mounting.
  • Conformity: CE EN 50081/2, EN50082/2, self-certified.
Additional Notes: ARTECO MOTION TECH reserves the right to change the physical hardware and/or software specifications without notice. The document version is 20100203.
See more

Catalog excerpts

I/O CANOpen module-1

I/O modules via CanBus allow building of a remotely controlled system for the exchange of digital data using a screened single-pair cable. This decreases the amount of cabling needed and the operating costs, without penalizing system performance. SU modules' compatibility with the CANOpen fieldbus enables them to be connected to other modules and systems compliant with the same standard, which are easily found on the market. The CANOpen module is small and quickly attached: it can be placed on the machine and connected to the electrical control panel with a single cable.

 Open the catalog to page 1
I/O CANOpen module-2

CHARACTERISTICS DESCRIPTION NOTES FIELDBUS CanBus CANOpen 2.0b POWER SUPPLY REQUIREMENTS Standard in slave mode Power supply voltage 24 Vdc ±20% DIGITAL INPUT & OUTPUT CONFIGURATION 32 digital inputs Opto-isolated 24Vdc PNP 64 digital inputs Opto-isolated 24Vdc PNP Opto-isolated 24Vdc PNP 16 digital inputs + 16 digital outputs 1.8 Amp/output, Max 4.4 Amps on each group of 4 outputs Protected against short-circuits, over-current, overheating, over-voltage and power voltage inversion Opto-isolated 24Vdc PNP 32 digital inputs + 32 digital outputs 1.8 Amp/output, Max 4.4 Amps on each group of 4 outputs...

 Open the catalog to page 2

All Arteco Motion Tech catalogs and technical brochures

  1. Arteco 5000

    2  Pages

  2. Arteco 3000

    2  Pages

  3. Arteco LPR

    2  Pages

  4. Arteco Next

    2  Pages

  5. ISaGRAF

    2  Pages

  6. SU310-PLC

    2  Pages

  7. SU-PLC

    2  Pages

  8. SU210

    2  Pages

  9. SU112-TOUCH

    2  Pages

  10. SU112

    2  Pages

  11. CND51

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.