USCX150
15Pages

{{requestButtons}}

Catalog excerpts

USCX150 - 1

f*t<M ’TfaaAwiemertt & (fatfaot SftzciaJUaU

Open the catalog to page 1
USCX150 - 2

THE TECHNOLOGY BEHIND THE MEASUREMENT The USCX series non-invasive flowmeters work on the transit time ultrasonic principle. This involves sending and receiving ultrasonic pulses from a pair of sensors and examining the time difference in the signal. We use clamp-on transducers that are mounted externally on the surface of the pipe and which generate pulses that pass through the pipe wall. The flowing liquid within causes time differences in the ultrasonic signals, which are then evaluated by the flowmeter to produce an accurate flow measurement. The key principle of the method applied is...

Open the catalog to page 2
USCX150 - 3

Fixed Installation Bn, SPECIFICATION • Pipe diameter range 10 mm to 6,500 mm • Temperature range forsensors -30 °C to +250 °C (-22 °F to +482 °F), highertemperatures available on request • Lockable and sturdy IP 66 polycarbonate flowmeter enclosure • Selectable three-line LCD display and full keypad • Uptoten inputoroutputslotsavailable • Measurement of two flows simultaneously FEATURES • Dual flow monitoring with sum, average, difference and maximum calculations • Process output options including current, open-collector, relay • Communication options RS 485, Modbus RTU, Profibus PA and...

Open the catalog to page 3
USCX150 - 4

USCX150 Technical Data FLOWMETER Performance Measurement principle Flow velocity range Resolution Repeatability Accuracy Turn down ratio Measurement rate Response time Damping of displayed value Gaseous and solid content of liquid media Ultrasonic transit-time difference 0.01 ...25 m/s 0.25 mm/s 0.15 % of measured value, ±0.015 m/s Volume flow: ±1... 3 % of measured value depending on application ±0.5 % of measured value with process calibration Flow velocity (mean): ±0.5 % of measured value 1/100 (equivalent to 0.25 ... 25 m/s) 1 Hz (standard) 1 s (standard), 90 ms (optional) 0 ... 99 s...

Open the catalog to page 4
USCX150 - 5

General Enclosure type Wall mounted Operating temperature Housing material Measurement channels Calculation functions Average, difference, sum, maximum (dual-channel use only) Power supply 100 ... 240 V AC, 50/60 Hz 9 ... 36 V DC Special solutions (e.g. solar panel, battery) on request LCD graphic display, 128 x 64 dots, backlit Power consumption Operating languages English, French, German, Dutch, Spanish, Italian, Russian, Czech, Turkish, Romanian (others on request) Abbildungen Images USCX150 with transducer pair

Open the catalog to page 5
USCX150 - 6

Type RS 232, USB cable (optional), RS 485 (optional), Modbus RTU (optional), HART* compatible (optional), Profibus PA (optional) Transmitted data Measured and totalised value, parameter set and configuration, logged data Internal data logger Storage capacity Logged data Approx. 30,000 measurements (each comprising up to 10 selectable measurement units), loggersize5 MB Approx. 100,000 measurements (each comprising up to 10 selectable measurement units), loggersize 16 MB All measured and totalised values, parameter sets Operating systems Download of measured values/parameter sets, graphical...

Open the catalog to page 6
USCX150 - 7

Process inputs (galvanically isolated) Temperature PT100 (clamp-on sensors), three- or four-wire circuit, measurement range: -30 ... +250 °C (-22 ... +482 °F), resolution: 0.1 K, accuracy: ±0.2 K 0/4 ... 20 mA active or 0/4 ... 20 mA passive, U = 30 V, Ri = 50 Ω, accuracy: 0.1 % of measured value Process outputs (galvanically isolated) Current 0/4 ... 20 mA active/passive (RLoad < 500 Ω), 16 bit resolution, U = 30 V, accuracy: 0.1 % Digital open-collector Value: 0.01 ... 1000/unit, width: 1 ... 990 ms, U = 24 V, Imax = 4 mA Digital relay 2 x Form A SPST (NO and NC), U = 48 V, Imax = 250 mA...

Open the catalog to page 7
USCX150 - 8

HAZARDOUS AREA ENCLOSURE General Enclosure type Degree of protection Operati ng temperatu re Housing material Finish Dimensions Weight Ex-certification code Ex-certification number Wall mounted (additional to USCX150 flowmeter) IP 66 accordingto EN 60529 -20... +40 °C (-4... +104 °F) Grade LM6 cast alloy RAL 7035 epoxy powder coated 358 (h) x 278 (w) x 218 (d) mm Approx. 20.0 kg (with USCX150 flowmeter) II 2G/D Exd IIBT4-T6 IP67 CESI 01ATEX 063 Pipe diameter range Dimensions of sensor heads Material of sensor heads 10 ... 250 mm for type K4Ex 50 ... 3,000 mm for type K1Ex 60 (h) x30 (w) x34...

Open the catalog to page 8
USCX150 - 9

Pipe diameter range Dimensions of sensor heads Material of sensor heads 50 ... 3,000 mm for type K1N/E 50 ... 6,500 mm for type K1L 60(h) x 30 (w) x34 (d) mm Stainless steel Material of cable conduits Temperature range Degree of protection Standard cable lengths (forshort periods up to +300 °C (+572 °F)) IP 66 accordingto EN 60529 (IP 67 and IP 68 on request) Type K1L: 5.0 m

Open the catalog to page 9
USCX150 - 10

Pipe diameter range Dimensions of sensor heads Material of sensor heads 10 ... 250 mm for type K4N/E 10 ... 250 mm for type K4L 43 (h) x 18 (w) x 22 (d) mm Stainless steel Material of cable conduits Temperature range Type K4N/E: Stainless steel Type K4L: -30 ... +80 °C (-22 ... +176 °F) (for short periods up to +300 °C (+572 °F)) IP 66 accordingto EN 60529 (IP 67 and IP 68 on request) Standard cable lengths

Open the catalog to page 10
USCX150 - 11

Extension cable Available lengths Cable type Material cablejacket Operati ng temperatu re Minimum bend radius Cable connection Connection types Termination into transmitter Junction box, Amphenol connectors (for transducer type N) SMB connector (SubMiniature version B) Direct cable connection (terminal block)

Open the catalog to page 11
USCX150 - 12

USCX150 Technical Data TRANSDUCER MOUNTING ACCESSORIES General Diameter range and mounting types Clamping set (metal strap with screw), stainless steel: DN 10 ... 40 Metallic straps and clamps: Metallic straps and clamps: Metallic mounting rail and straps (available on request): DN 50 ... 250 or DN 50 ... 3,000 Mounting fixture for flexible hoses Custom made mounting bracket, stainless steel (available on request) Metallic mounting rail with transducers Example of mounting fixture for flexible hoses

Open the catalog to page 12
USCX150 - 13

USCX150 Technical Data PT100 CLAMP-ON SENSORS General Type Measurement range Response time Dimensions of sensor heads Material of sensor heads Material of cable jacket Cable length PT100 transducer fixed to pipe PT100 with wired cable connection

Open the catalog to page 13

All Arkon Flow Systems catalogs and technical brochures

  1. USCX200

    14 Pages

  2. USCX100

    13 Pages

  3. MQU & MHU

    8 Pages

  4. Brochure ENG

    24 Pages