Brochure ENG
24Pages

{{requestButtons}}

Catalog excerpts

Brochure ENG - 1

flow systems 4-20 mA CURRENT WI-FI 3G/GPRS/GSM LOOP f*t<M TJica^wiemmt & (fatfooi SfieciaMtU

Open the catalog to page 1
Brochure ENG - 2

Modular design suitable from most basic to most advanced applications ■%> The MAGX2 has an innovative modular design "Plug & Play" %> Accuracy ±0.2% of actual value %> Sizes from DN10 to DN1000 %> Connection: DIN, ANSI, JIS, others on request Communication protocol: all communications via Modbus RTU %> Temperature sensor %> Graphic display with multi-language menu Intelligent sensor design: digital communication allows communication between the transmitter and the sensor for up to a 500 m range. Calibration data is stored in the sensor 1) Wi-Fi, 3G/GPRS/GSM, TCP/IPand Bluetooth...

Open the catalog to page 2
Brochure ENG - 3

flowmeter for agricultural and applications multiple 1) Available in 3 sizes (25, 50 and 80mm) Manifold clamping flanges connections, compatible with fitting kits for DIN, BSP, NPT and other common connections Accuracy: ±1% from 10% to 100% of full scale range 1) LCD display 128x64 px graphical 1) Empty pipe detection and battery saving mode Body material: glass filled polypropylene 1) Working pressure 150psi or 10.3 bars Agrimag: powered by 6 standard AA batteries, easily interchangeable — AgrimagP: powered by 9-35 VDC power supply, one frequency output — AgrimagP2: powered by 9-35 VDC...

Open the catalog to page 3
Brochure ENG - 4

Applications % Water & Wastewater - distribution networks, irrigation, sludge/sewage, water treatment, leakage management, desalination, marine, checking of pumps and water wells ^ Public utilities - water supply system, sewage systems, wastewater, industrial water, sludge, human waste, etc. % Petrochemical/chemicals - corrosive liquids, chemicals, industrial water, waste water % Paper & Pulp - low concentration of pulp, additives, bleaches, colorants, liquor % Construction - building material slurry, sediment slurry, cement slurry, industrial water, etc. Hygienic/Sanitary - potable water...

Open the catalog to page 4
Brochure ENG - 5

Power supply That is basic configuration for a MAGX2 working unit. It only allows communication with the flowmeter via keypad and does not include any output or data-logging function. Flowrate and totalizer can be checked on the display only. Arkon offers a wide range of optional modules which are not necessary for a working unit but can be added to the basic configuration to add extra features. %) Arkon offers 4-20 mA output and two pulse outputs. Both options can be used separately or combined. Out of the two pulse options only one pulse option could be used or installed at any given...

Open the catalog to page 5
Brochure ENG - 6

Choose your communication A standard for computer communication. RS485 communication module A standard for industrial communication, up to 32 devices on one line without repeaters. Termination resistor may be needed. Bluetooth communication module 3G/GPRS/GSM communication module Wireless communciation system. The measurement can be evaluated from anywhere in the world. Wi-Fi communication module Easy communication between flowmeter, PC or PLC system with no data cables needed. A MODBUS RTU over TCP/IP (serial) protocol is used. M-Bus communication module Standard for the remote reading of...

Open the catalog to page 6
Brochure ENG - 7

Transmitter specifications MAGX2 Measurable media Conductive fluids Min. media electrical conductivity >5pS/cm or >20pS/cm for demineralized water Flow range fl Displayed values (m3, |_ us.gal, UK.gal), positive, negative, total volume and auxiliary (dearable) volume, sensor temperature Accuracy ±0.2% (0.5 -10 m/s) of actual value Power supply Power consumption Communication protocol Flow direction Ambient temperature Adjustable filter constant Max. electronics weight (including housing) Housing material Housing dimensions 12-35 VDC, 90-250 VAC, including battery back-up option Max. 15VA...

Open the catalog to page 7
Brochure ENG - 8

Remote version: Tolerance of built-in length: Standard pressure: Max. electronics weight (including housing) 2 kg Housing material Aluminium + powder coating Cable terminal 3+lxM16x1.5 IP68 cable glands Electronics protection IP68 / NEMA 6

Open the catalog to page 8
Brochure ENG - 9

Adjustable time constant 1-30 samples %> Maintenance free Two built-in earthing electrodes %> No moving parts in measuring tube Battery %) Standard 2 x 3.6 V battery pack placed inside the transmitter. Battery life up to 5 years. %> Optional 5 x 3.6 V battery pack placed inside the transmitter. Battery life up to 10 years. % External battery pack for battery life up to 15 years %) Battery conservation when the pipe is empty for all battery options Applications % Water & Wastewater - distribution networks, irrigation, sludge/sewage, water treatment, desalination, marine, checking of pumps...

Open the catalog to page 9
Brochure ENG - 10

Measurable media Conductive fluids Other features Test of excitation coils Empty pipe detection Zero flow adjustment Flow simulator Verification tool available Excitation frequency Real time Sensor specifications MAGB1 Adjustable filter constant Error logger Data logger Certification 1/60 Hz, 1/30 Hz, 1/15 Hz, 1/5 Hz, 1.5625 Hz, 3.125 Hz, 6.25 Hz Clock function for data-logging Pulse output with programmable volume function and pulse width 1 -30 samples Logging last 10 errors 1820 records, selectable interval of logging (5 min - 24 h) EMC, ES, PED, IP68, OIML R49, MID Connection types DIN,...

Open the catalog to page 10
Brochure ENG - 11

ANSI DN 0D D1 Cx0d L H-compact H-remote Compact version: Remote version: Electronics weight (Including Housing) 1.5 kg Housing material Aluminium + powder coating Cable terminals 1+1xM16x1.5 IP68 cable glands Electronics protection

Open the catalog to page 11
Brochure ENG - 12

Applications %> Water & Wastewater-distribution networks, irrigation, sludge/sewage, water treatment, leakage management, desalination, marine, checking of pumps and water wells %) Petrochemical/chemicals - corrosive liquids, dosing of additives, chemicals, industrial water, waste water, pulp liquids t Paper & Pulp - colorants, bleaches, additives %> Construction - building material slurry, industrial water ^ Sanitary - potable water metering, food & beverage, pharmaceutical, medium and high density fluids, blending, dosing, batching Advantages MAGS1 is a stand-alone version of flowmeter,...

Open the catalog to page 12

All Arkon Flow Systems catalogs and technical brochures

  1. USCX200

    14 Pages

  2. USCX150

    15 Pages

  3. USCX100

    13 Pages

  4. MQU & MHU

    8 Pages