Melt pressure transducers and transmitters
20Pages

{{requestButtons}}

Catalog excerpts

Melt pressure transducers and transmitters - 1

Melt pressure transducers and transmitters Melt pressure transducers and transmitters trasmettitori trasduttori trasmettitori trasduttori trasmettitori trasduttori trasmettitori trasmettitori trasduttori trasmettitori trasduttori trasmettitori trasduttori trasmettitori trasduttori trasmettitori trasduttori trasmettitori trasmettitori trasmettitori trasmettitori trasmettitori trasduttori trasmettitori trasduttori trasmetti trasmettitori trasduttori trasmettitori trasduttori trasm trasduttori trasmettitori trasduttori trasmettitori trasduttori trasm trasmettitori trasduttori trasmettitori trasduttori trasme trasduttori trasmettitori trasduttori trasmettitori trasmettitori trasduttori trasmettitori trasduttori trasmettitori

Open the catalog to page 1
Melt pressure transducers and transmitters - 2

Melt pressure transducers and transmitters GEFRAN Melt sensors are pressure/temperature transducers and transmitters designed to be used in environments that reach very high temperatures and are able to measure media pressure up to 538°C. Based on two main constructive technologies (with filling fluid - extensimetric technology, and fluid free – silicon piezoresistive technology), Gefran high temperature pressure sensors are available in 4 different designs: rigid rod, flexible sheath, flexible with thermocouple, and exposed tip. Because they are highly immune to noise, these Melt pressure...

Open the catalog to page 2
Melt pressure transducers and transmitters - 3

Fluid-free pressure sensor: IMPACT technology Series I (IMPACT) Melt sensors employ the piezoresistive principle: the pressure medium is converted into an electrical signal by a Wheatstone bridge built with 4 piezoresistors. The innovative IMPACT technology is patented by Gefran and is made up of 3 elements: The package: - guarantees mechanical transfer of the pressure to the chip without the use of transmission fluids - has been optimized to make the sensor stronger and more reliable (all parts in contact with the process and therefore subject to wear are up to 35 times stronger than...

Open the catalog to page 3
Melt pressure transducers and transmitters - 4

Why choose GEFRAN Mercury-free solutions Concerned about environmental problems and in agreement with the RoHS directive, GEFRAN offers a wide range of "mercury-free" sensors:: • W series, with FDA-approved filling oil • K series, with NaK filling, declared GRAS • I series, completely fluid free Melt pressure transducers and transmitters GTP The new GTP coating, the result of Gefran research, ensures longer life for Gefran Melt sensors. Principal characteristics include: • low coefficient of friction • high hardness • high resistance to high temperatures • high resistance to chemical attack...

Open the catalog to page 4
Melt pressure transducers and transmitters - 5

GUIDE TO CODE The code identifying the various models of GEFRAN Melt sensors has three sections, with the following meanings. :example: ME2 - Melt sensor with mercury filling fluid, 4-20 mA output in current with flexible rod plus thermocouple W FDA oil K Nak I Impact IJ Injection application, Impact MJ Injection application, mercury flexible sheath flexible rod plus thermocouple exposed tips CAN-BUS DP404 digital output DP404 output: extensimeter, analog display output: extensimeter, digital display Atex, Intrinsic Safety Factory Mutual Explosion proof

Open the catalog to page 5
Melt pressure transducers and transmitters - 6

FILLING FLUID Extensimetric pressure transducers for high temperature SIGNAL AT AMBIENT PRESSURE AMBIENT COMPENSATED TEMPERATURE RANGE (°C)(°F) TEMPERATURE RANGE OF MEASUREMENT FLUID (°C)(°F) ZERO THERMAL DRIFT DUE TO VARIATION OF MEASUREMENT FLUID TEMPERATURE (bar/10°C) TEMPERATURE SENSOR Version M32 (Thermocouple type “J” isolated junction) Version W32 (Thermocouple type “J” isolated junction) Version K32 (Thermocouple type “J” isolated junction MATERIAL IN CONTACT WITH PROCESS MEDIUM 15-5PH stainless steel with GTP coating 17-7 PH corrugated diaphragm with GTP coating for ranges < 100...

Open the catalog to page 6
Melt pressure transducers and transmitters - 7

FILLING FLUID PRECISION CLASS (%FSO) AMBIENT COMPENSATED TEMPERATURE RANGE (°C)(°F) PERMITTED AMBIENT TEMPERATURE RANGE (°C)(°F) Version WE2 (Thermocouple type “J” isolated junction) Version KE2 (Thermocouple type “J” isolated junction) 15-5PH stainless steel with GTP coating 17-7 PH corrugated diaphragm with GTP coating for ranges < 100 bar (1500 psi) 17-7 PH corrugated diaphragm with GTP coating 15-5PH stainless steel with GTP coating 17-7 PH corrugated diaphragm with GTP coating for ranges < 100 bar (1500 psi) Up to 538°C Inconel with GTP coating ME0 series – Rigid rod ME1 series – Flex...

Open the catalog to page 7
Melt pressure transducers and transmitters - 8

Output Volt FILLING FLUID Extensimetric pressure transmitters for high temperature PRESSURE RANGE (bar) SUPPLY VOLTAGE (Vdc) SIGNAL AT RATED PRESSURE SIGNAL AT AMBIENT PRESSURE AMBIENT COMPENSATED TEMPERATURE RANGE (°C)(°F) PERMITTED AMBIENT TEMPERATURE RANGE (°C)(°F) TEMPERATURE RANGE OF MEASUREMENT FLUID (°C)(°F) ZERO THERMAL DRIFT DUE TO VARIATION OF MEASUREMENT FLUID TEMPERATURE (bar/10°C) PROTECTION DEGREE (IEC-529) TEMPERATURE SENSOR MATERIAL IN CONTACT WITH PROCESS MEDIUM ELECTRICAL CONNECTIONS PROCESS CONNECTIONS MAIN APPLICATIONS MN2 Version (Thermocouple type “J” isolated...

Open the catalog to page 8
Melt pressure transducers and transmitters - 9

Digital Output FILLING FLUID PRECISION CLASS (%FSO) POWER SUPPLY PROTOCOL DP404 CAN OPEN, with baud rate selection from 10K to 1M baud (default 500K baud) DP404 CAN OPEN, with baud rate selection from 10K to 1M baud (default 500K baud) DP404 CAN OPEN, with baud rate selection from 10K to 1M baud (default 500K baud) STRAIN GAUGE HOUSING COMPENSATED TEMPERATURE RANGE STRAIN GAUGE HOUSING MAXIMUM TEMPERATURE RANGE WD2 Version (Thermocouple type “J” isolated junction) KD2 Version (Thermocouple type “J” isolated junction) TEMPERATURE RANGE OF MEASUREMENT FLUID (°C)(°F) ZERO THERMAL DRIFT DUE TO...

Open the catalog to page 9
Melt pressure transducers and transmitters - 10

Hazardus Area FILLING FLUID Extensimetric pressure transmitters for high temperature SUPPLY VOLTAGE (Vdc) SIGNAL AT RATED PRESSURE SIGNAL AT AMBIENT PRESSURE AMBIENT COMPENSATED TEMPERATURE RANGE (°C)(°F) PERMITTED AMBIENT TEMPERATURE RANGE (°C)(°F) TEMPERATURE RANGE OF MEASUREMENT FLUID (°C)(°F) ZERO THERMAL DRIFT DUE TO VARIATION OF MEASUREMENT FLUID TEMPERATURE (bar/10°C) PROTECTION DEGREE (IEC-529) TEMPERATURE SENSOR PROTECTION MODE MATERIAL IN CONTACT WITH PROCESS MEDIUM ELECTRICAL CONNECTIONS PROCESS CONNECTIONS MAIN APPLICATIONS Version MX2 (Thermocouple type “J” isolated junction)...

Open the catalog to page 10

All ARICO Technology Co. catalogs and technical brochures

  1. Thermocouple

    2 Pages

  2. FC-HMI

    8 Pages

  3. 1366172139

    8 Pages

  4. 1366172277

    8 Pages

  5. 1366177595

    5 Pages

  6. 1366177299

    5 Pages

  7. 1324542733

    6 Pages