Product catalog summary

Overview

This document details the specifications, features, and operational guidelines for a series of programmable temperature and process controllers (models C100, C200, C300, C400, C500, and PC series). These controllers utilize a 16-bit microprocessor core with PID control and self-tuning capabilities, designed for precise control of temperature, humidity, pressure, flow rate, proportional valves, and pH values.

Main Features

  • Microprocessor Core: 16-bit CPU with PID control and self-tuning (auto-tuning) for optimal parameter adjustment.
  • Input Signal Options: Supports thermocouples (types K, J, R, S, B, E, N, T, W3, W5, PL-II), RTDs (PT-100 DIN, JPT-100 JIS), analog signals (0-10V, 4-20mA, mV ranges).
  • Control Outputs: Multiple output types including relay, pulse voltage (PWM for SSR), linear analog signals (0-20mA, 0-10V, etc.), and proportional valve control.
  • Drive Capability: Can drive SSR, SCR, motor valves, and other contactors.
  • Control Modes: Forward/reverse control for heating or cooling processes; dual output models support two-way PID control (heating and cooling).
  • Remote Set Value (SV): SV can be set remotely via analog input signals.
  • Alarm Functions: 26 selectable alarm modes including heater break alarm (HBA) with current transformer (CT) detection for heating line breakage.
  • Re-transmission Output: Converts process variable (PV) or control output to analog signals for recorders or other devices.
  • Manual/Auto Output: Supports manual override and automatic control switching.
  • Serial Communication: Optional RS-232 or RS-485 interfaces supporting Modbus RTU and ASCII protocols with baud rates up to 38,400 bit/s; RS-485 supports up to 31 controllers on a network.
  • Program Control: Allows programming of up to 16 temperature segments with customizable intervals and repeat counts.

Technical Specifications

  • Power Supply: AC 90-240V (50/60Hz) or optional DC 24V (non-polarized).
  • Power Consumption: 4-5 VA depending on model.
  • Operating Environment: 0 to 65°C (storage), 0 to 50°C (operation), 20-90% RH.
  • Memory: EEPROM with 10-year data retention.
  • Display: Dual display with SV in green and PV in red; digit height varies by model (10-14 mm).
  • Control Accuracy: ±0.3% FS ±1 digit (except B and S thermocouples).
  • Relay Contact Rating: 8A, 250VAC.

Alarm and Safety Features

  • Heater Break Alarm (HBA): Uses CT to detect heating line current; triggers alarm if current falls below set threshold for a defined time period. Output requires relay or logic voltage type control signal.
  • Alarm Output Timing: Configurable hold/delay times from -1999 to +9999 seconds with options for delayed output, immediate output with self-hold, or timed output.
  • Process Control Alarm Output (Optional): Alarms can be programmed to trigger at specific temperature program segments for additional control actions (e.g., furnace door opening, material feeding).

Auto-Tuning Function

The auto-tuning function uses relay ON/OFF cycling to detect process dynamics and calculate optimal PID parameters. During tuning, the process must remain undisturbed. Auto-tuning stops and switches to manual mode without changing PID values if exceptions occur (power failure, output ON/OFF exceeding 2 hours, or manual override activation).

Heating/Cooling Control (Optional)

Dual output models allow simultaneous heating and cooling control with configurable gap or overlap between outputs via parameter "dbnd" to prevent output conflicts.

Manual/Auto Mode Operation

  • Switching between manual and automatic modes is done by holding the A/M key for 2 seconds.
  • Manual mode allows direct setting of output levels (OUT1: 0-100%, OUT2: -0.1 to -100%).
  • Manual mode is indicated by a yellow "MAN" lamp.

Input Signal Broken-Line Detection

If sensor input signal is lost, the controller displays "oL" then "open" and uses the highest temperature as the alarm comparison value to prevent unsafe conditions.

Startup and Display

  • Upon power-up, all LEDs light for 3 seconds to check display integrity.
  • Displays maximum detection value, input signal type code, and unit before entering normal PV/SV display and automatic control mode.

Wiring and Installation

  • Detailed wiring diagrams provided for power supply, input signals, outputs, alarms, CT input, and communication interfaces.
  • Note on terminal function conflicts: if terminals overlap in function, only one function can be selected.
  • Power supply polarity is not required for 24V AC/DC input.
  • Panel cutout dimensions vary by model (e.g., C100: 48×48 mm, C300: 72×72 mm, C400: 96×96 mm, C500: 96×48 mm).

Ordering Information

Models and options can be configured by selecting input types, output types, alarm options (including HBA variants), communication interfaces (RS232/RS485), and power supply options. The document includes detailed order codes for customization.

Summary

This series of controllers offers versatile, reliable, and precise process control with advanced features such as PID auto-tuning, multiple input/output options, comprehensive alarm functions including heater break detection, and flexible communication capabilities. They are suitable for a wide range of industrial applications requiring temperature and process parameter control.

See more

Catalog excerpts

1366172139-1

Applicable to control of temperature, humidity, pressure, flow rate, proportion valve and PH value. Temperature signals can be selected from software, offering high reliability and easy operation Switching power design offers high noise resistance P.LD. auto-tuning, self-tuning, HAN/AUTO out 12. SMaiRS«ModBusflURTUWASCIIttiC JMEBVPTX 38400 bit/s Heating / Cooling Control Auto / Manual Switching Heater Break Alarm Celsius/ Fahrenheit 1.16 bit microprocessor operating core doing PID + Self-tuning 2. Various options of input signals (thermocouples, RTD, analog signals, etc.) 3. Main control output can select relay, pulse voltage, linear analog signals 4. Can drive all types of contactors, SSR, SCR, 3-line proportional motor valve, etc 5. Can set reverse / forward control (heating or cooling process) 6. Dual-output models can do cooling / heating two-way PID controlling 7. Set Value (SV) can employ analog signal input to achieve Remote Set Value setting 8. 26 types of alarm modes for option ; can be added with broken-line detecting alarm function (HBA) 9. Re-transmission function can convert PresentValue (PV) or controlling output amount into analog signal output for recorder or other applications 10. Provided with manual output mode 11. Manual and auto output 12. Serial communication function supports RTU and ASCII format of Modbus. The Baud rate can reach as 13. Programmed controlling provides 16 temperature levels whose operating intervals and repeat frequency

 Open the catalog to page 1
1366172139-2

Heater Break Alarm(HB A): Detects the working currentof heating lines with CT and the controller judges if the heating line breaks and make alarm output. 1. Output is atON status 2. Current value is lower than the set value of H BA 3. Continues for more than (A lTr) time. Range :-5~-1999 4. Controlling signal of Outl must be relay or logic voltage displays setalarm value. lAlarm Output Hold/Delay Time: AITr ~A3Tr parameters process output time controlling in accordance with each alarm. Range: -1999 sec. -9999 sec (exceptHBA). The meanings are as follows: 1. Negative value: when alarm condition...

 Open the catalog to page 2
1366172139-3

AtSvSV (overshoot) Set parameter AtSv in case the temperature overshoots around SV. Auto-tuning of PID AT adopts Relay ON/OFF to detect the dynamic characteristics of the Process, and calculate the best parameter combination of P, I, & D according to the data. During AT, the operation must be kept under the condition where the process is not interfered. After AT is completed (AT lamp goes off), the three parameters of P, I, & D will renew themselves, and then enter a new PID auto-control mode. If any one of the following situations occurs, AT will stop and enter manual mode without changing values...

 Open the catalog to page 3
1366172139-4

Serial Communication (Optional) Users can opt for RS-232 or RS-485 serial communication interface to connect the control with PC, PLC or HMI. Connections can be as many as 31 controllers with RS-485. RS-485 Auto/ Manual Shifting In PV & SV display mode, hold A/M key for 2 sec. to switch Auto/Manual mode. In manual mode, the yellow lamp of “MAN” is alighted. Press left key to set OUT1 Range: 0.0 ~ 100.0%; OUT2 Range: -0.1 ~ -100.0% Broken-line Detecting of Input Signal When signals from the sensor of the controller fail, the temperature value will rise to the maximum value and then the controller...

 Open the catalog to page 4
1366172139-5

Order Code Input Type None RELAY RELAY Logic Voltage SSR) Wiring Diagram , 24V AC/DC Note: If defined terminal repeats terminals of other functions. Only one function can be selected. If power supply is 24V AC/DC, polarity can be disregarded at input terminal. 2 3 1 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output Measuring Input Proportion valve control

 Open the catalog to page 5
1366172139-6

1 2 3 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output Measuring Input Power Supply Proportion valve control Measuring Input Proportion valve control 1 2 3 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output Power Supply Proportion valve control 1 2 3 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output

 Open the catalog to page 6
1366172139-7

Technical Specification Power Supply Power Consumption Unit Weight Storage / Operat Data Backup Memory Accuracy 0.3 % FS ± 1DIG except for thermocouples of B and S type ) Digit Height (mm) SV(green) / PV(red) Alarm Output Controlling Measure Relay contact Logic Voltage PWM pulse voltage (to drive SSR): ON=24V, OFF=0V (20mA Max.) Current: 0 ~20mA (Input Impedance: 600 Voltage: 0~10V (Input Impedance: 1K Linear Analog Input Type K, J, R, S, B, E, N, T, W3, W5, PL-II Input Impedance: approx. 1K Max.) Panel Cutout and Dimensions

 Open the catalog to page 7
1366172139-8

Technical Specification Power Supply Power Consumption Unit Weight Storage / Operat Data Backup Memory Accuracy 0.3 % FS ± 1DIG except for thermocouples of B and S type ) Digit Height (mm) SV(green) / PV(red) Alarm Output Controlling Measure Relay contact Logic Voltage PWM pulse voltage (to drive SSR): ON=24V, OFF=0V (20mA Max.) Current: 0 ~20mA (Input Impedance: 600 Voltage: 0~10V (Input Impedance: 1K Linear Analog Input Type K, J, R, S, B, E, N, T, W3, W5, PL-II Input Impedance: approx. 1K Max.) Panel Cutout and Dimensions Unitmm

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.