Applicable to control of temperature, humidity, pressure, flow rate, proportion valve and PH value. Temperature signals can be selected from software, offering high reliability and easy operation Switching power design offers high noise resistance P.LD. auto-tuning, self-tuning, HAN/AUTO out 12. SMaiRS«ModBusflURTUWASCIIttiC JMEBVPTX 38400 bit/s Heating / Cooling Control Auto / Manual Switching Heater Break Alarm Celsius/ Fahrenheit 1.16 bit microprocessor operating core doing PID + Self-tuning 2. Various options of input signals (thermocouples, RTD, analog signals, etc.) 3. Main control output can select relay, pulse voltage, linear analog signals 4. Can drive all types of contactors, SSR, SCR, 3-line proportional motor valve, etc 5. Can set reverse / forward control (heating or cooling process) 6. Dual-output models can do cooling / heating two-way PID controlling 7. Set Value (SV) can employ analog signal input to achieve Remote Set Value setting 8. 26 types of alarm modes for option ; can be added with broken-line detecting alarm function (HBA) 9. Re-transmission function can convert PresentValue (PV) or controlling output amount into analog signal output for recorder or other applications 10. Provided with manual output mode 11. Manual and auto output 12. Serial communication function supports RTU and ASCII format of Modbus. The Baud rate can reach as 13. Programmed controlling provides 16 temperature levels whose operating intervals and repeat frequency
Open the catalog to page 1Heater Break Alarm(HB A): Detects the working currentof heating lines with CT and the controller judges if the heating line breaks and make alarm output. 1. Output is atON status 2. Current value is lower than the set value of H BA 3. Continues for more than (A lTr) time. Range :-5~-1999 4. Controlling signal of Outl must be relay or logic voltage displays setalarm value. lAlarm Output Hold/Delay Time: AITr ~A3Tr parameters process output time controlling in accordance with each alarm. Range: -1999 sec. -9999 sec (exceptHBA). The meanings are as follows: 1. Negative value: when alarm...
Open the catalog to page 2AtSvSV (overshoot) Set parameter AtSv in case the temperature overshoots around SV. Auto-tuning of PID AT adopts Relay ON/OFF to detect the dynamic characteristics of the Process, and calculate the best parameter combination of P, I, & D according to the data. During AT, the operation must be kept under the condition where the process is not interfered. After AT is completed (AT lamp goes off), the three parameters of P, I, & D will renew themselves, and then enter a new PID auto-control mode. If any one of the following situations occurs, AT will stop and enter manual mode without changing...
Open the catalog to page 3Serial Communication (Optional) Users can opt for RS-232 or RS-485 serial communication interface to connect the control with PC, PLC or HMI. Connections can be as many as 31 controllers with RS-485. RS-485 Auto/ Manual Shifting In PV & SV display mode, hold A/M key for 2 sec. to switch Auto/Manual mode. In manual mode, the yellow lamp of “MAN” is alighted. Press left key to set OUT1 Range: 0.0 ~ 100.0%; OUT2 Range: -0.1 ~ -100.0% Broken-line Detecting of Input Signal When signals from the sensor of the controller fail, the temperature value will rise to the maximum value and then the...
Open the catalog to page 4Order Code Input Type None RELAY RELAY Logic Voltage SSR) Wiring Diagram , 24V AC/DC Note: If defined terminal repeats terminals of other functions. Only one function can be selected. If power supply is 24V AC/DC, polarity can be disregarded at input terminal. 2 3 1 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output Measuring Input Proportion valve control
Open the catalog to page 51 2 3 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output Measuring Input Power Supply Proportion valve control Measuring Input Proportion valve control 1 2 3 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output Power Supply Proportion valve control 1 2 3 RSV Input CT Input Transmitting Communication Alarm1 Alarm2 Alarm3 Output
Open the catalog to page 6Technical Specification Power Supply Power Consumption Unit Weight Storage / Operat Data Backup Memory Accuracy 0.3 % FS ± 1DIG except for thermocouples of B and S type ) Digit Height (mm) SV(green) / PV(red) Alarm Output Controlling Measure Relay contact Logic Voltage PWM pulse voltage (to drive SSR): ON=24V, OFF=0V (20mA Max.) Current: 0 ~20mA (Input Impedance: 600 Voltage: 0~10V (Input Impedance: 1K Linear Analog Input Type K, J, R, S, B, E, N, T, W3, W5, PL-II Input Impedance: approx. 1K Max.) Panel Cutout and Dimensions
Open the catalog to page 7Technical Specification Power Supply Power Consumption Unit Weight Storage / Operat Data Backup Memory Accuracy 0.3 % FS ± 1DIG except for thermocouples of B and S type ) Digit Height (mm) SV(green) / PV(red) Alarm Output Controlling Measure Relay contact Logic Voltage PWM pulse voltage (to drive SSR): ON=24V, OFF=0V (20mA Max.) Current: 0 ~20mA (Input Impedance: 600 Voltage: 0~10V (Input Impedance: 1K Linear Analog Input Type K, J, R, S, B, E, N, T, W3, W5, PL-II Input Impedance: approx. 1K Max.) Panel Cutout and Dimensions Unitmm
Open the catalog to page 8All ARICO Technology Co. catalogs and technical brochures
-
Displacement Transducers General
20 Pages
-
Thermocouple
2 Pages
-
TR100 Signal Transmitter
2 Pages
-
Q9000-Inverter
8 Pages
-
FC-HMI
8 Pages
-
servo motor and drive
13 Pages
-
Ceramic_Band_Heaters
30 Pages
-
Solid State Relay
19 Pages
-
Temperature controllers
27 Pages
-
1366172277
8 Pages
-
1366177595
5 Pages
-
1366177299
5 Pages
-
1324542733
6 Pages