ECOLINE
8Pages

{{requestButtons}}

Catalog excerpts

ECOLINE - 1

ECOLINE UM 045 / UMP 045 / UMPC 045 • asy filling, cleaning E and pumping over • nbeatable ergonomics, U optimal handling • High filtration performance • ay be combined with portable M oil diagnostic system optionally • ptionally with integrated O particle monitor • ptionally with integrated O humidity sensor 80.70-3e

Open the catalog to page 1
ECOLINE - 2

Oil service - simple, quick and compact ECOLINE ECOLINE base model - UM 045 Easy, compact and ergonomic The UM 045 is delivered equipped with hoses, and is ready to connect. With ECOLINE hydraulic or lubrication systems can simply be filled, cleaned For easy transport, electrical cables, as well as suction and return hose, or fluid can be pumped over without using the filter function. The ergonomic are mounted with support fixtures on the carrier device. The tool can be design allows simple handling also on closest work space. stowed in the basket of the carrier device. Protection of...

Open the catalog to page 2
ECOLINE - 3

… with integrated particle monitor ECOLINE with integrated particle monitor – UMPC 045 The integrated particle monitor in the UMPC 045 permanently monitors the oil cleanliness during the filtering process. A humidity sensor (LubCos H2O) is optionally available, which permanently monitors the humidity of the oil during the filtering process. Cleanliness class monitoring can be selected for “cleaning” or “filling” with a change-over cock. The ordinal numbers of the particle sizes are shown on the display in accordance with ISO 4406:1999. Also the humidity in %rh is shown on the display. Via a...

Open the catalog to page 3
ECOLINE - 4

… with programmable oil diagnostic system ECOLINE with oil diagnostic system PODS Pro – UMP 045 PODS Pro turns off. In addition with PODS Pro the cleanliness class can be determined online on high-pressure lines or per bottle sampling in accordance with all standard cleanliness classifications. ECOLINE in the UMP 045 version, is prepared for connnection of the portable ARGO-HYTOS oil diagnostic system PODS Pro. With few turns of your hand PODS Pro can be attached to the ECOLINE and is immediately ready for operation. Oil purity is monitored in the bypass with PODS Pro when cleaning...

Open the catalog to page 4
ECOLINE - 5

operating costs 1. Economical Efficiency through ARGO-HYTOS Fluid Management systems. Fast return on investment by extended service intervals and increased machine availability. machine life time 2. User-friendly filter element change The filter element can be removed from the housing together with the cover. The dirt retention valve ensures that solid particle sediment is completely removed with the filter element. During operation, the fluid passes through the filter element from the inside to the outside, which eliminates the need for flushing the filter housing. 3. Switching functions...

Open the catalog to page 5
ECOLINE - 6

Cleaning speed Determining the cleaning speed In graph D1-D2 the cleaning speeds are shown in relation to the filter fineness (cleanliness information according to ISO 4406:1999). The values are recorded by laboratory methods and they may be influenced by environmental conditions (such as continuous additional introduction of dirt on running systems, high water content, etc.). All characteristic curves (see graphs D1-D2) relate to a reference oil volume of 180 l and a nominal volume flow of 15 l/min. Initial value cleanliness The cleaning speed depends on the efficiency of the filter...

Open the catalog to page 6
ECOLINE - 7

Hydraulic connection Hoses: Suction hose NG 32, length 2,7 m, with suction strainer 280 µm, pressure hose NG 25, length 2,7 m Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info service sheet 00.20). Other fluids on request. Electrical connection / Electric motor Electric motor, air cooled fan type Cable: length 6 m Electro motor types: 1 ~ 230 V / 50 Hz 3 ~ 400 V / 50 Hz (3 ~ 460 V / 60 Hz) Type of protection: IP 54 (See selection chart) Temperature range of fluids 0 °C ... +65 °C (also see fluid viscosity range) Ambient temperature range 0 °C ... +50 °C Options...

Open the catalog to page 7
ECOLINE - 8

Selection Chart ECOLINE basic model – UM 045 UM 045-1553 ECOLINE with integrated particle monitor OPCom – UMPC 045 UMPC 045-15735 45 l/min *** 3EN2 Please request our data sheet no. 100.10 for more detailed information on the OPCom particle monitor. ECOLINE prepared for connection of oil diagnostic system PODS** – UMP 045 UMP 045-1553 Please request our brochure for more detailed information on the PODS Pro oil diagnostic system. * The exact determination of the cleanliness class is possible in a viscosity range of 15 mm2/s to 250 mm2/s. ** without PODS Pro *** Indications at 50 Hz. At...

Open the catalog to page 8

All ARGO-HYTOS catalogs and technical brochures

  1. MLS3-06

    10 Pages

  2. ES 075

    6 Pages

  3. Light Line

    4 Pages

  4. RC series

    4 Pages

  5. TS3 MTS2

    6 Pages

  6. TS4 MTS

    6 Pages

  7. SR4P2-B2

    4 Pages

  8. SR1P2-A2

    4 Pages

  9. PRM7-10

    10 Pages

  10. PRM8-06

    4 Pages

  11. PRM2-04

    20 Pages

  12. PRM6-10

    20 Pages

  13. PRM7-06

    10 Pages

  14. PRM2-06

    20 Pages

  15. PRM7-04

    10 Pages

  16. Coils

    18 Pages

Archived catalogs

  1. EXAPOR MAX 2

    3 Pages

  2. Guidelines

    21 Pages