video corpo

ECOLINE

ECOLINE

ECOLINE

Product catalog summary
Overview: The document provides detailed information on the ECOLINE oil service units, specifically models UM 045, UMP 045, and UMPC 045. These units are designed for easy filling, cleaning, and pumping of hydraulic or lubrication systems, offering high filtration performance and optional integration with diagnostic systems.
Key Features:
  • Ergonomics and Handling: The units are designed for optimal handling and ergonomics, allowing easy operation even in confined spaces.
  • Filtration Performance: Utilizes EXAPOR®MAX 2 ultra-fine elements for high separation efficiency, ensuring excellent cleanliness levels and component protection.
  • Optional Features: Can be equipped with an integrated particle monitor and humidity sensor for continuous monitoring of oil cleanliness and humidity.
Model Specifications:
  • UM 045: Basic model equipped with hoses, ready for connection, and features easy transport and storage options.
  • UMPC 045: Includes an integrated particle monitor for real-time cleanliness monitoring and optional humidity sensor.
  • UMP 045: Prepared for connection with the portable oil diagnostic system PODS Pro, allowing for online cleanliness class determination and selective cleaning.
Advantages:
  • Economical: Efficient fluid management systems extend service intervals and increase machine availability.
  • User-Friendly: Easy filter element change with a dirt retention valve for complete removal of solid particles.
  • Compact Design: Facilitates easy transportation and operation in various positions.
  • Ergonomics: Designed to minimize physical effort, with optimized weight distribution for easy maneuverability.
Technical Specifications:
  • Cleaning Speed: Determined by filter efficiency, nominal volume flow, and oil volume, with specific calculations provided for different scenarios.
  • Hydraulic and Electrical Connections: Includes details on hose specifications, electric motor types, and protection standards.
  • Operating Conditions: Suitable for mineral oil and biodegradable fluids, with specified temperature and viscosity ranges.
Additional Options: Water-absorbing filter elements and hose extensions are available upon request, along with detailed information on the PODS Pro oil diagnostic system.
See more

Catalog excerpts

ECOLINE-1

ECOLINE UM 045 / UMP 045 / UMPC 045 • asy filling, cleaning E and pumping over • nbeatable ergonomics, U optimal handling • High filtration performance • ay be combined with portable M oil diagnostic system optionally • ptionally with integrated O particle monitor • ptionally with integrated O humidity sensor 80.70-3e

 Open the catalog to page 1
ECOLINE-2

Oil service - simple, quick and compact ECOLINE ECOLINE base model - UM 045 Easy, compact and ergonomic The UM 045 is delivered equipped with hoses, and is ready to connect. With ECOLINE hydraulic or lubrication systems can simply be filled, cleaned For easy transport, electrical cables, as well as suction and return hose, or fluid can be pumped over without using the filter function. The ergonomic are mounted with support fixtures on the carrier device. The tool can be design allows simple handling also on closest work space. stowed in the basket of the carrier device. Protection of components...

 Open the catalog to page 2
ECOLINE-3

… with integrated particle monitor ECOLINE with integrated particle monitor – UMPC 045 The integrated particle monitor in the UMPC 045 permanently monitors the oil cleanliness during the filtering process. A humidity sensor (LubCos H2O) is optionally available, which permanently monitors the humidity of the oil during the filtering process. Cleanliness class monitoring can be selected for “cleaning” or “filling” with a change-over cock. The ordinal numbers of the particle sizes are shown on the display in accordance with ISO 4406:1999. Also the humidity in %rh is shown on the display. Via a W-Lan...

 Open the catalog to page 3
ECOLINE-4

… with programmable oil diagnostic system ECOLINE with oil diagnostic system PODS Pro – UMP 045 PODS Pro turns off. In addition with PODS Pro the cleanliness class can be determined online on high-pressure lines or per bottle sampling in accordance with all standard cleanliness classifications. ECOLINE in the UMP 045 version, is prepared for connnection of the portable ARGO-HYTOS oil diagnostic system PODS Pro. With few turns of your hand PODS Pro can be attached to the ECOLINE and is immediately ready for operation. Oil purity is monitored in the bypass with PODS Pro when cleaning hydraulic...

 Open the catalog to page 4
ECOLINE-5

operating costs 1. Economical Efficiency through ARGO-HYTOS Fluid Management systems. Fast return on investment by extended service intervals and increased machine availability. machine life time 2. User-friendly filter element change The filter element can be removed from the housing together with the cover. The dirt retention valve ensures that solid particle sediment is completely removed with the filter element. During operation, the fluid passes through the filter element from the inside to the outside, which eliminates the need for flushing the filter housing. 3. Switching functions The...

 Open the catalog to page 5
ECOLINE-6

Cleaning speed Determining the cleaning speed In graph D1-D2 the cleaning speeds are shown in relation to the filter fineness (cleanliness information according to ISO 4406:1999). The values are recorded by laboratory methods and they may be influenced by environmental conditions (such as continuous additional introduction of dirt on running systems, high water content, etc.). All characteristic curves (see graphs D1-D2) relate to a reference oil volume of 180 l and a nominal volume flow of 15 l/min. Initial value cleanliness The cleaning speed depends on the efficiency of the filter elements...

 Open the catalog to page 6
ECOLINE-7

Hydraulic connection Hoses: Suction hose NG 32, length 2,7 m, with suction strainer 280 µm, pressure hose NG 25, length 2,7 m Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info service sheet 00.20). Other fluids on request. Electrical connection / Electric motor Electric motor, air cooled fan type Cable: length 6 m Electro motor types: 1 ~ 230 V / 50 Hz 3 ~ 400 V / 50 Hz (3 ~ 460 V / 60 Hz) Type of protection: IP 54 (See selection chart) Temperature range of fluids 0 °C ... +65 °C (also see fluid viscosity range) Ambient temperature range 0 °C ... +50 °C Options Water-absorbing...

 Open the catalog to page 7
ECOLINE-8

Selection Chart ECOLINE basic model – UM 045 UM 045-1553 ECOLINE with integrated particle monitor OPCom – UMPC 045 UMPC 045-15735 45 l/min *** 3EN2 Please request our data sheet no. 100.10 for more detailed information on the OPCom particle monitor. ECOLINE prepared for connection of oil diagnostic system PODS** – UMP 045 UMP 045-1553 Please request our brochure for more detailed information on the PODS Pro oil diagnostic system. * The exact determination of the cleanliness class is possible in a viscosity range of 15 mm2/s to 250 mm2/s. ** without PODS Pro *** Indications at 50 Hz. At 60 Hz...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.