Catalog excerpts
Features Universal power supply: 20 to 250 Vac and 20 to 250 Vdc Input: Sensor of type NPN, PNP, logic, NAMUR, contact and alternating up to 500V (on input 1 only). Sensor supply Isolated analog output(s) (A/2A) 0-4-20mA (active/passive current) or 0-10V voltage. Relay outputs (R): 2 change-over relays (8A/250 VAC on resistive load). • Digital output (N) isolated RS485 Modbus/Jbus • Pulse output NPN and PNP Sensor break detection (input NAMUR) and self-diagnosis. Isolation between input/outputs/suppl. Mode simulation allowing to validate the configuration or the installation. Programming either with the microconsole or by the PC software SlimSET via a standard USB /pUSB cable. • Frequency measurement (from 0.01Hz to 130KHz) depending on the sensor type (TPIvxx I and IC). • Counting up to 2 000 000 000 with saving of the counters (version TPIvxxIC). • Calculation between channels (sum, substraction, average) (version TPIv20xx). • Detection of the rotation direction on encoder in phase quadrature (TPIv20xx). • Integration function (TPIvxxIC). • Possibility to programme the 2nd input with function logic input (TPIv20xx). • 2 relays, independently programmable as alarm (setpoint) or pulses. Configu tion Dimensi numbering of the terminals A, B, C, D Voltage presence Led C (green) Relay 1 Relay 2 pconsole plug pUSB for programming via PC software Inputs: xx : 10 (1 input) 20 (2 inputs) yy : I (frequency) IC (frequency + counting) Easy programming with a micro-console or by the PC software SlimSET (via a standard USB / pUSB cable). Programming with the Micro-console The graphical rear-lit LCD with tactile keyboard allows to visualise the following information: - the value of the measure with its unit, - the value of the analog output(s), - the product tag name, - the status of the relay outputs and the RS485 communication • Scrolling messages for programming help in various languages • Passcode protected programming • Programmable keys for direct access Programming by PC: SlimSET Programming software (Windows environment) allowing: The storage of configurations as files which can be consulted, modified, duplicated or loaded into the converters. The edition and printing of files with or without having a converter connected. Outputs: A analog I/U isolated 2A analog I/U isolated R 2 change-over relays N RS 485 communications P output NPN PNP Available versions:
Open the catalog to page 1Inputs(s) • Sensor type: npn, pnp, logic, namur, contact, alternating - Logic: voltage up to 18V Low level <1.2V High level > 2.1V - Npn or contact: U max.: 15V, I max.: 4mA - Pnp: U max.: 20V, I max.: 2mA - Namur: Input resistance: 1KQ to the GND Low level <1.2mA High level > 2.1mA - Alternating (input E1 only): AC (L) from 2V to 250 Veff. AC (H) from 10V to 500 Veff. Input resistance: 1.2MQ • Sensor supply: 18V±10%/20mA, or 8.5V ±0.5V/20mA if 1 of the 2 inputs is in namur • Frequency measurement: from 0.01Hz to 130 KHz depending on the type of sensor - accuracy 0.015% with gate =...
Open the catalog to page 2All ARDETEM SFERE catalogs and technical brochures
-
TPIv10
2 Pages
-
µCv 10
2 Pages
-
TRM4/µTAC 400
2 Pages
-
EVAN3000
2 Pages
-
EVA3000
2 Pages
-
TPI 41K
2 Pages
-
Series TPIv/µCv
2 Pages
-
TPIv 12/µCv 12
1 Pages
-
TAIv60
2 Pages
-
Series µCs
4 Pages
-
Series TPls
4 Pages
-
TMvL2-CAPvL2-com-EN
2 Pages
-
TMv10-CAPv10-com-EN
2 Pages
-
TM2F-TN2F-com-EN
2 Pages
-
TPIv 10I
2 Pages
-
ATIS H
2 Pages
-
TMvL3
2 Pages
-
TMvL2
2 Pages