TPI 41K - 1

PROGRAMMABLE CONVERTER • Universal input : ±100mV, ±1V, ±10V, ±20mA, Pt100 3 wire, APt100 2 wire, Ni 100, thermocouple, resistance and potentiometer. Typical response time 100ms (+40ms for the analog output). • Supply for 2-wire sensor • 1 insulated programmable analog output 0-4-20mA (active) current. • 2 relay outputs : 2 inverting relays. (8A/250 VAC on resistive load). • 1 insulated digital output RS485 Modbus/Jbus Detection of the sensor rupture. Insulation between input / outputs / supply. Self-zero, self-calibration and self-diagnosis Mode driver : the analog output and the relays are piloted by the digital data link, or locally by the micro-console. Function simulation of the input measure Easy programming on front face by a micro-console or by PC software SUPERVision. Introduction: rack drawer 19'' 3U Europe card 100 x 220 mm Programming by Micro-console This miniaturised micro-console connected on the front face of the instruments with an extension flex allows : The visualisation of the measure and the state of the analog outputs and the relays. The visualisation and modification of the programming. The teleloading of programming files for duplication to other converters. Programming by PC : SUPERVision Software for programming and analysis (Windows environment) allowing : The storage of configurations as files which can be consulted, modified, duplicated or loaded into the converters. The edition and printing of files with or without connected converter. Digital data link RS485 (Modbus/Jbus) Allows communication with processing and explotation sets (PLCs), as well as a complete configuration of the input, the output and the safeties. The reading of the measures by the digital data link is performed by programming, either in ASCII format or in double integer format. Accessories: empty rack equipped for 1 to 14 drawers Blank front face 6TE Power supply : High or low voltage (specify on order) (2) high voltage : 90...265 Vac or 88...350 Vdc (3) low voltage : 20...40 Vac or 20...64 Vdc Frequency of the supply : 50 Hz to 400 Hz (VAC) Power draw : 4 W max. 6 VA max. For a converter with universal input + analog output + 2 relays + digital output, powered in 230 V, request reference : TPI41K ARN-2

Open the catalog to page 1
TPI 41K - 2

°C Inputs of the TPI41K Types of INPUTS Outputs of the TPI41K Types of OUTPUTS (1) Line resistance <25Q (2) Line resistance <10Q and R. max. 400Q (3) Or 25 mV typical (50mV Max.) ♦ CJC efficiency : ±0.03°C/°C ±0.5°C from -10°C to +60°C MR measure range Square root extraction Between analog output and digital output. Between supply and [analog outputs / relay contacts]. Between analog outputs and relay contacts. Between input and [supply / outputs]. a A 12 mA pulsed current allows the detection of line or sensor rupture * Cut off : the display of the Mconsole and the TPI output remain at...

Open the catalog to page 2

All ARDETEM SFERE catalogs and technical brochures

  1. TPIv10

    2 Pages

  2. µCv 10

    2 Pages

  3. EVAN3000

    2 Pages

  4. EVA3000

    2 Pages

  5. TAIv60

    2 Pages

  6. Series µCs

    4 Pages

  7. Series TPls

    4 Pages

  8. TPIv 20I

    2 Pages

  9. TPIv 10I

    2 Pages

  10. ATIS H

    2 Pages

  11. TMvL3

    2 Pages

  12. TMvL2

    2 Pages