TMvA-TMvP-AVTNv-CAPvPLUS-com-EN
2Pages

{{requestButtons}}

Catalog excerpts

TMvA-TMvP-AVTNv-CAPvPLUS-com-EN - 1

MEASURE TRANSMITTERS AC/DC current or voltage TMvA/TMvP AVTNv/CAPvPLUS ARDETEM ♦ This range is declined into 2 versions TMvA/AVTNv AC current or voltage input TMvP/CAPvPLUS DC current or voltage input which will accept a non-standard signal and convert it into a 0/10V voltage or 0-4/20mA current (active or passive) standardized insulated output signal. For processing or transmission of signals... -Version HI: High isolation 5kV ♦ Options: (specify on order) -Reversed or shifted scales. -Bidirectional inputs. -5Adc input (TMvP/CAPvPLUS) -Bidirectional voltage output ±10V. Lr>1kΩ -Bidirectional current output ±20mA. Lr<320Ω -Passive current output 0-4/20mA U:30V max. -Standard response time: 200ms Option shorter response time: from 7ms to 200ms Option longer response time: from 200ms to 30s (specify on order) ♦ Accessibilities: Plug-off connectors for screwed connections. Internal selection of the input and output calibers by jumpers, accessible behind the front face. 5Aac Current input, safened by a screwed connector. Transfer ♦ Accuracy rating ♦ Ripple ♦ Galvanic isolation : ≤ 0.3 (ac) and ≤ 0.2 (dc) : ≤ 0.5% : 3kV eff. 50Hz 1min. (input / output / supply) Version Hi (5kV eff. - 50Hz - 1 min.) : ≤ 200ms [Tr] (in standard) : 1.7Hz (-3 decibels) [BP:0,35/Tr] : ≤ 0.015%/°C ♦ Response time ♦ Pass-band ♦ Temperature coeff. Analog output Supply Voltage presence Led ON (green) Down scale Up scale ♦ Operating temperature : -20°C to +60°C. ♦ Storage temperature : -20°C to +70°C. ♦ Installation: Pollution degree 2 / voltage surge II Compliance with standards: Electrical safety EN 61010-1 ATEX 2014/34/UE (area 2) ... ... EN 60079-0, EN 60079-15 Directive EMC 2014/30/UE ... ... EN 61326-1 Marking: numbering of the terminals: 1 2 3 4 F,H Selection of the calibers: (a): output (b): input Protection: housing/terminals: IP20 Removable terminal blocks for screwed connections (2.5 mm², flexible or rigid) Weight: 290g (with packaging) Self-extinguishing case of black UL 94VO PA66. Mounting in cabinet: latching on symmetrical DIN rail Wiring Supply + - 2-wire transmitter TMvP/CAPvPLUS only Passive current output B2 B3 Active current and voltage output + 0-4/20mA passive external source 30V max. This appliance is designed for industrial applications. It has to be installed in an electrical cabinet, or equivalent. 69510 SOUCIEU EN JARREST - France - Tél. 04

Open the catalog to page 1
TMvA-TMvP-AVTNv-CAPvPLUS-com-EN - 2

x E [x/xx] Sx [x/xx] Tx [xx] Example for a • DC voltage input transmitter with -10 to 100 V • Current output -5 to 5mA • Galvanic isolation 5KV • Response time 30s ARDETEM - CA CO2016/41 D - 01/18 - Any data in this documentation may be modified without prior notice. AC current/voltage input ARDETEM reference: TMvA SFERE reference: AVTNv DC current/voltage input ARDETEM reference: TMvP SFERE reference: CAPv PLUS ' ’ - ... Galvanic isolation 3KV/50Hz/1min HI ... Galvanic isolation 5KV/50Hz/1 min Input calibers to be defined: down scale / up scale unit - e-mail : info@ardetem.com http :...

Open the catalog to page 2

All ARDETEM SFERE catalogs and technical brochures

  1. TPIv10

    2 Pages

  2. µCv 10

    2 Pages

  3. EVAN3000

    2 Pages

  4. EVA3000

    2 Pages

  5. TPI 41K

    2 Pages

  6. TAIv60

    2 Pages

  7. Series µCs

    4 Pages

  8. Series TPls

    4 Pages

  9. TPIv 20I

    2 Pages

  10. TPIv 10I

    2 Pages

  11. ATIS H

    2 Pages

  12. TMvL3

    2 Pages

  13. TMvL2

    2 Pages