Series TPls

Series TPls

Series TPls

Product catalog summary
Overview: The document describes the TPIs series, which are measure converters for industrial signals such as process, temperature, resistance, and frequency. These converters can function independently or within a local network, offering interfaces for analog and relay outputs, as well as logic inputs. They support communication via Modbus, Ethernet, Profibus, and Profinet, with optional Datalogger capabilities.
Specifications: The TPIs series features a DIN rail footing for power and communication signal distribution, a 24 V DC power supply, and galvanic isolation of 2.5 kV between input/output/supply. The housing dimensions are 7.2 x 114 x 114 mm. Programming is facilitated through a µUSB plug or µswitches for certain versions. The devices are suitable for ATEX area 2 environments.
Programmable Converters: Various models are available, each supporting different input types (mA, mV, V, PT100, frequency, TRMS voltage/current) and offering one or two analog outputs. Fast versions (<10 ms) are available for specific models.
Configurable Converters: These models allow easy configuration via micro-switches without recalibration. They support universal inputs and PT100 inputs, with one or two outputs.
Optional Modules: Additional modules include analog outputs, relay outputs, logic inputs, and measure inputs, enhancing the system's flexibility and functionality.
Concentrator Supervisor: The TPIv M acts as a power supply controller and measure concentrator, supporting configuration and supervision of TPIs networks. It offers data storage on a microSD card and communication via RS485 Modbus, Ethernet, Profibus, or Profinet.
Applications: Examples include sending multiple measures to a PLC via MODBUS or Modbus TCP, transmitting measures between sites, and exchanging inputs/outputs between remote sites.
See more

Catalog excerpts

Series TPls-1

INPUTS/OUTPUTS ACQUISITION SYSTEM The series TPIs consists of measure converters for industrial signals (process, temperature, resistance, frequency…) which can either operate in an independent and autonomous way or be interconnected in a local network with interfaces of analog and relay outputs, or logic inputs. Possibility to add on the communication bus a supervision and concentrator module with output Modbus, Ethernet, Profibus, Profinet and optionally with Datalogger. DIN rail footing for the distribution of the power supply and the communication signals. Power supply 24 V DC Galvanic isolation between input/output/supply: 2.5 kV Extra thin housing: 7.2 x 114 x 114 mm. Easy programming by µUSB plug on front face or quick configuration by µswitches for the versions S. ATEX area 2 Typical example of implementing: Analog outputs Sensors of pressure, temperature, flow, level, move … Output to PLC: Modbus / Ethernet / Profibus / Profinet. Relay outputs

 Open the catalog to page 1
Series TPls-2

Programmable converters: - TPIs 12: Input mA, mV, V  1 analog output - TPIs 212: Input mA, mV, V  2 analog outputs - TPIs 11: Universal input  1 analog output - TPIs 211: Universal input  2 analog outputs - TPIs PT100: PT100 input  1 analog output - TPIs 50: Frequency input  1 analog output - TPIs 250: Frequency input  2 analog outputs - TPIs 60: 2 frequency inputs  1 analog output - TPIs 260: 2 frequency inputs  2 analog outputs - TPIs 61: 2 frequency inputs + integrator  1 analog output - TPIs 261: 2 frequency inputs + integrator  2 analog outputs - TPIs 70: TRMS voltage input ...

 Open the catalog to page 2
Series TPls-3

Optional modules: Modules of analog outputs TPIs 2A: 2 isolated analog outputs Modules of relay outputs TPIs 4R: 4 relay outputs TPIs 4A: 4 isolated analog outputs Modules of logic inputs Modules of measure inputs TPIs 2T: 2 logic inputs, non isolated TPIs 4E11: 4 universal inputs TPIs 4T: 4 logic inputs, isolated TPIs 6T: 6 logic inputs, non isolated Concentrator supervisor: The TPIv M is a 24 VDC power supply controller and a concentrator of measures for the converters or modules of the series TPIs. It allows configuring and supervising the measures and the inputs/outputs of a local network...

 Open the catalog to page 3
Series TPls-4

Examples of applications: 1 - Sending of several measures on a PLC, in MODBUS (RS485) or Modbus TCP (Ethernet) T° inputs Furnace 1 Speed input  Local bus 2 - Sending of the measures from a site to a remote site: 4 relay outputs, images of the 4 logic inputs of the site A. 2 analog outputs, images of the 2 inputs 4/20 mA of the site A. 3 - Exchanges of inputs/outputs between 2 remote sites: 4 relay outputs, images of the 4 logic inputs of the site A. 2 outputs 4/20 mA, copies of the 2 inputs 4/20 mA of the site A. TPIv MEER TPIv MEER 4 relay outputs, copies of the 4 logic inputs of th

 Open the catalog to page 4

All ARDETEM SFERE catalogs and technical brochures

  1. TPIv10

    2  Pages

  2. µCv 10

    2  Pages

  3. EVAN3000

    2  Pages

  4. EVA3000

    2  Pages

  5. TPI 41K

    2  Pages

  6. TAIv60

    2  Pages

  7. Series µCs

    4  Pages

  8. TPIv 20I

    2  Pages

  9. TPIv 10I

    2  Pages

  10. ATIS H

    2  Pages

  11. TMvL3

    2  Pages

  12. TMvL2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.