Catalog excerpts
PROGRAMMABLE SIGNAL CONDITIONERS series TPIv/µCv ARDETEM 1 analog output 2 isolated analog outputs Features • Universal power supply: 20 to 250 Vac and 20 to 250 Vdc • Process input: (TPIv400/450) (µCv3012/3212) ±100mV, ±1V, ±10V, ±270V, ±20mA • Universal input: (TPIv401/451)(µCv3011/3211) ±100mV, ±1V, ±10V, ±270V, ±20mA, Pt100, Ni 100 (2, 3 or 4 wire), ∆Pt100 thermocouple, resistance and potentiometer. • Average response time 150ms (15ms version F) • Supply for 2-wire sensor • Isolated analog outputs (A) 0-4-20mA current (active/passive) or 0-10V voltage. Relay outputs (R) : 2 change-over relays (8A/250 VAC on resistive load). Digital communications (N) isolated RS485 Modbus/Jbus Sensor break detection and self-diagnosis. Isolation input / outputs / supply. Mode simulation allowing to validate the configuration or the installation. Programming either with micro-console or by the PC software SlimSET via a standard USB/µUSB cable. Configuration Easy programming on front face with a micro-console or with the PC software SlimSET (via a standard USB/µUSB cable). Programming with the Micro-console The graphical rear-lit LCD with tactile keyboard allows to visualise the following information: - the measured value with its unit, - the value(s) of the analog output(s), - the product tag name, - the status of the relay outputs and the RS485 communications. • Scrolling message for programming help in various languages • Passcode protected programming • Programmable keys for direct access Programming software (Windows environment) allowing: The storage of the configurations as files which can be consulted, modified, duplicated or loaded into the converters. The edition and printing of files with or without having a signal conditioner connected. Dimensions 136 mm (with µconsole) numbering of the terminals: A, B, C, D Analog output Relay Relay 1 2 Supply 1 Voltage presence LED ON (green) Relay 2 µconsole plug µUSB for programming via PC software Supply: 20 to 250 Vac and 20 to 250Vdc Power draw: 2.8 W max. 8 VA max. Dielectric withstanding: 3.0 kV-50Hz-1min. Operating temperature: -20 to +60°C Storage temperature: -20 to +70°C Installation: Pollution degree 2 / voltage surge II
Open the catalog to page 1Connectings Inputs (3) CJC efficiency (-20 to +60°C): Internal CJC: ±2°C ±0.03°C/°C CJC (option terminal): ±1°C MR Measure range Thermal drift <150ppm /°C Outputs of the TPIv401/TPIv400 / pCv3011/pCv3012 0-4/20mA passive external source 30V max. ! The voltage or current outputs are not independent. One output type only to be activated by programming (V or mA). Outputs of the TPIv451/450(R) / pCv3211/3212(R) TPIv451/450 / pCv3211/3212 Version with 2 independent isolated analog outputs. TPIv451/450R / pCv3211/3212R Version 2 independ. isolated anal. outputs and 2 relays. (1) Sensor break...
Open the catalog to page 2All ARDETEM SFERE catalogs and technical brochures
-
TPIv10
2 Pages
-
µCv 10
2 Pages
-
TRM4/µTAC 400
2 Pages
-
EVAN3000
2 Pages
-
EVA3000
2 Pages
-
TPI 41K
2 Pages
-
TPIv 12/µCv 12
1 Pages
-
TAIv60
2 Pages
-
Series µCs
4 Pages
-
Series TPls
4 Pages
-
TMvL2-CAPvL2-com-EN
2 Pages
-
TMv10-CAPv10-com-EN
2 Pages
-
TM2F-TN2F-com-EN
2 Pages
-
TPIv 20I
2 Pages
-
TPIv 10I
2 Pages
-
ATIS H
2 Pages
-
TMvL3
2 Pages
-
TMvL2
2 Pages