ATIS H-1

SELF-POWERED LOOP ISOLATOR ARDETEM Coding 1 channel loop isolator ARDETEM reference: ATIS-H SFERE reference: ELIT93-H 2 channel loop isolator ARDETEM reference: ATI2S-H SFERE reference: ELIT940-H • The ATIS/ELIT solves common point problems which may occur on the measure loops and also reduces the rejection of the disturbances induced on the cables. • The ATIS/ELIT isolates the sensors or transmitters from the process receivers PLC's, recorders, etc.) • The transparency to the HART protocole allows the user to communicate with the digital protocole HART via the ATIS/ELIT. • HART PROTOCOLE TRANSPARENCY • 1 or 2 isolated measure channels • Isolation between input / output • Transfer ratio 1 / 1 • High transmission accuracy • High load impedance • Powered by the input signal • Reduced dimensions ons Insulation of current loops. Insulation of measure transmitters from the PLC boards. Insulation of 4-20mA signals from thermocouples which may start to have insulation problems when the temperature increases. Application example with a temperature sensor with hart digital output: 24 Vdc supply insertion pyrometer t° sensor with HART digital output I = 15mA T° = 150°C —TLTL HART communication HART console The ATIS/ELIT transmits the measure information in the form of a DC current, + the HART digital pattern with a galvanic partition of 2kV.

 Open the catalog to page 1
ATIS H-2

Technical features at 23°C ATI2S-H/ELIT940-H 2 channels Load loss Max. voltage drop (output loop open) Self-powered by the input loop Self-powered by the input loop mounting on symmetrical horizontal DIN rail mounting on symmetrical horizontal DIN rail Screw-in connectors for flexible or rigid 2.5 mm² wires 100 g Screw-in connectors for flexible or rigid 2.5 mm² wires 140 g Current Internal voltage drop at 20mA Impedance, in Ω at 20 mA Number of channels Current Max. load (Lr in Ω) admissible at 20 mA Power supply Nominal response time (0 to 90%) For a load Lr = 20 Ω Lr = 100 Ω Lr influence 100...

 Open the catalog to page 2

All ARDETEM SFERE catalogs and technical brochures

  1. TPIv10

    2  Pages

  2. µCv 10

    2  Pages

  3. EVAN3000

    2  Pages

  4. EVA3000

    2  Pages

  5. TPI 41K

    2  Pages

  6. TAIv60

    2  Pages

  7. Series µCs

    4  Pages

  8. Series TPls

    4  Pages

  9. TPIv 20I

    2  Pages

  10. TPIv 10I

    2  Pages

  11. TMvL3

    2  Pages

  12. TMvL2

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.