AQ 100 SERIES
36Pages

{{requestButtons}}

Catalog excerpts

AQ 100 SERIES - 1

RELhYRBLE power 00 SERIES ARC FLASH PROTECTION

Open the catalog to page 1
AQ 100 SERIES - 3

The AQ 100 reliability is based on unbeatable experience in the field of arc protection. The unique standard arc schemes ensure correct operation under any condition. When an arc burns there is

Open the catalog to page 3
AQ 100 SERIES - 4

THE WIDEST RANGE OF PRODUCTS ON THE MARKET The AQ 100 system enables arc flash protection systems over a wide range of applications. The full system can be anything from a single unit covering a few cubicles of switchgear to a complex multi incomer configuration with hundreds of units. Due to the unique design of the AQ 100 system, the number of units is nearly unlimited. The variety of sensors meet all philosophies of building up an arc flash system, it is possible to use point sensors, fiber sensors or a mixture of the both. The AQ 100 system is always fast in operation, by adding an...

Open the catalog to page 4
AQ 100 SERIES - 5

SENSORS (for MV and LV) POINT SENSORS FIBER SENSORS For light and light & pressure Plastic fiber or multithread glass fiber in variable lengths LOW VOLTAGE PRODUCTS AQ-110FLV CURRENT AND FIBER SENSOR UNIT Flush mounted current and light sensing main unit Flush mounted current and light sensing main unit 3 current inputs, up to 12 light detectors and one light detecting fiber 3 current inputs, up to 3 light detecting fibers AQ-101LV POINT SENSOR UNIT AQ-101DLV POINT SENSOR UNIT Flush mounted light sensing unit installed as sub-unit to AQ110PLV or standalone for light only system Din rail...

Open the catalog to page 5
AQ 100 SERIES - 6

BENEFITS OF ARC PROTECTION The AQ 100 is designed utilizing the most modern technology with a focus on simplicity while maintaining both flexibility and function. It is built to meet the growing demands in both LV and MV switchgear and control gear applications ranging from basic standalone to more complex system solutions. The AQ 100 series is designed and tested according to the latest protection relay standards and is hence suitable for installations in any environment, such as utility, power plant, wind-power, off-shore, marine, oil and gas, mining, steel or any other heavy industry...

Open the catalog to page 6
AQ 100 SERIES - 7

Use of quenching device reduces the calorie/cm2 energy release typically to less than 1. The main purpose of an arc flash protection is to protect both substation personnel and equipment from the consequences of and arc fault. An arc protection system detects the fault in less than 2 ms and including the delay in the breaker the time for extinguishing the arc is normally less than 70 ms. A normal selective over current protection can have operation times up to 500 ms. In case of an arc fault in a switchgear equipped only with traditional feeder protection, the risk for severe injuries to...

Open the catalog to page 7
AQ 100 SERIES - 8

ARCTEQ INNOVATION: Re-usable arc quenching device according to IEC 60947 and UL 2748 ARC FLASH INCIDENTS Arc flash faults are the most devastating types of faults known in power distribution systems. Arc flash incidents in medium and low voltage air insulated switchgear and control gear are known to cause annually a number of fatalities and personal injuries, mainly by 2nd degree and higher burns. Arc flash faults cause also severe equipment damage leading to time consuming repairs and extended power outages. Arc flash has been greatly researched in the last decade and standards such as...

Open the catalog to page 8
AQ 100 SERIES - 9

ARCTEQ INNOVATION: Dedicated and dependable protection with standard arc schemes ARC FLASH PROTECTION – THE NEW NORMAL IN POWER GRID PROTECTION ARCTEQ’S UNIQUE STANDARD ARC SCHEMES – IMPROVED SECURITY THROUGH SIMPLICITY During the last decade the application of arc flash protection based on light sensing has become the new normal in power protection. Arc flash protection provides unquestionable benefits, such as improved speed, selectivity and cost effectiveness. Arc flash protection has been introduced to all continents and applied in all types of electrical power distribution systems...

Open the catalog to page 9
AQ 100 SERIES - 10

Standard arc scheme layout for low voltage switchgear with two incoming circuit breakers and a tie breaker.

Open the catalog to page 10
AQ 100 SERIES - 11

Standard arc scheme layout for medium voltage switchgear with two incoming circuit breakers and a tie breaker.

Open the catalog to page 11
AQ 100 SERIES - 12

ARCTEQ INNOVATION: Adding pressure criteria in the arc flash protection BACKGROUND The first generations of arc flash protection relays utilized light sensitive arc sensors alone as the tripping criteria. Advances combined arc light and current sensing for the dual sensing method to further increase the reliability of the protection system. However, the traditional current and light-based dual sensing system may overtrip when installed in equipment involving air magnetic circuit breakers. As well in some cases, especially in low voltage systems, the absence of current transformers makes it...

Open the catalog to page 12
AQ 100 SERIES - 13

AQ-110P is a sophisticated microprocessor-based arc flash protection unit with combined current and arc sensing. When the AQ-110P detects an overcurrent in the incoming feeder and a light signal from a sub unit or a direct light sensor, it minimizes the damage caused by an arcing fault (arc flash) by tripping the circuit breaker sourcing the fault current. The AQ-110P complete system self-supervision function provides the highest level of dependability by continuously monitoring all internal system functions along with external connections. MEDIUM VOLTAGE PRODUCTS ORDER CODE AQ-110P - X X X...

Open the catalog to page 13
AQ 100 SERIES - 14

MEDIUM VOLTAGE PRODUCTS AQ-110F ARC Fiber sensor unit with overcurrent AQ-110F is a sophisticated microprocessor-based arc flash protection unit with combined current and arc sensing. When the AQ-110F detects an overcurrent in the incoming feeder and a light signal from a sub unit or a direct light sensor, it minimizes the damage caused by an arcing fault (arc flash) by tripping the circuit breaker sourcing the fault current. The AQ-110 complete system self-supervision function provides the highest level of dependability by continuously monitoring all internal system functions along with...

Open the catalog to page 14
AQ 100 SERIES - 15

AQ-101 ARC Point sensor unit AQ-101 is a sophisticated microprocessor-based arc flash protection unit for arc light detection. It is designed to minimize the damage caused by an arcing fault (arc flash) by tripping the circuit breaker sourcing the fault current. The AQ-101 acts as a sub unit to AQ-110P in an AQ 100 arc protection system. It can also function as standalone in light only systems. The AQ-101 complete system selfsupervision function provides the highest level of dependability by continuously monitoring all internal system functions along with external connections. MEDIUM...

Open the catalog to page 15