Overview: The TCD3000 Transmitter is a compact and robust device designed for precise, fast, and sensitive measurement of quasi-binary gas mixtures. It is suitable for use in harsh environments due to its stainless-steel housing and IP67 protection class.
Specifications: The transmitter features metal-to-metal connections ensuring high tightness and pressure resistance over 200 bars. It is corrosion-resistant with a gas path made of high-grade stainless steel and a glazed sensor protected against condensation and dust. The device can store curves for up to 99 gas pairs, allowing adaptability to changing measurement needs. It connects via axial pneumatic connections M10, facilitating easy assembly and disassembly.
Technical Data: The TCD3000 has dimensions of 54 mm x 80 mm x 34 mm and weighs approximately 500g. It operates on a power supply of 12 – 36 V DC, 24 W, with digital output options of RS485 or TTL and an analog output of 4-20 mA. The ambient temperature range is -10°C to 50°C, with a warm-up time of approximately 10 minutes. The flow rate ranges from 10l/h to 120l/h, with a T90-time of less than 1 second. Noise and drift at zero point are less than 50 ppm, and the device maintains repeatability within 50 ppm.
Measurement Components and Ranges: The TCD3000 can measure various gases including Hydrogen, Oxygen, Helium, Carbon Dioxide, Nitrogen, and others, with a basis range of 0% to 100% and smallest ranges varying per gas type.
Application Sectors: The transmitter is applicable in sectors such as oil & gas, petrochemicals, pharmaceuticals, food industry, power generation, and environmental technology. It is used for detecting gas leakages, air separation, pure gas production, and more.
Extended Application Information: The TCD3000 is used in processes like hydrogen production via electrolysis, annealing furnaces, blast furnace pig iron production, and nuclear power monitoring. It also aids in the analysis of hydrogen content in natural gas and ammonia production.
Contact Information: Archigas GmbH, Eisenstraße 3, D-65428 Rüsselsheim am Main, Germany. Tel: +49 (0)69 247544980, Email: [email protected], Website: www.archigas.de
See more

Catalog excerpts

Gas analyzer, transmitter TCD3000-1

Experts in hydrogen measurement

 Open the catalog to page 1
Gas analyzer, transmitter TCD3000-2

The compact and robust transmitter TCD3000 is recommended for precise, fast and sensitive measurement of (quasi-) binary gas mixtures. Due to the stainless-steel housing and the IP67 protection class, the unit can be used safely in harsh environments. The unit is completely equipped with metal-to-metal connections, so that a high degree of tightness and pressure resistance over 200 bars can be guaranteed. The gas-carrying parts and the sensor are corrosion-resistant: The gas path is made of highgrade stainless steel 1.4404, The sensor on the gas side is completely glazed. In addition, the sensor...

 Open the catalog to page 2
Gas analyzer, transmitter TCD3000-3

SPECIFICATIONS Dimensions with connectors; weight Power supply Digital Output RS485 or TTL, Baud rate 19200 / Data 8bit Analog Output Ambient temperature range Flow rate Drift at zero point Error due to change of ambient temperature 0,8 - 200 bara / 700 bara on request Error due to change of pressure (above 800hPa)

 Open the catalog to page 3
Gas analyzer, transmitter TCD3000-4

MEASUREMENT COMPONENTS AND RANGES Measuring Gas Basis Range Smallest Range

 Open the catalog to page 4
Gas analyzer, transmitter TCD3000-5

GENERAL APPLICATION SECTORS APPLICATION SECTORS - EXTENDED INFORMATION Hydrogen as an impurity Impurities in Hydrogen (ring lines) Input to Argon refining process Hydrogen production via electrolysis Annealing furnace Oil & gas, petrochemicals, chemicals and synthetics Lower explosion level (LEL) upper explosion level (UEL) Air separators and pure gas production Blast furnace pig iron production “top gas” Detection of gas leakages Pharmacy Basic oxygen furnace (BOF) top blown furnace oxidation of carbon in molten pig iron using Food industry Metals, minerals, pulp and paper Direct reduced iron...

 Open the catalog to page 5
Gas analyzer, transmitter TCD3000-6

APPLICATION SECTORS - EXTENDED INFORMATION Turbo generator, monitoring of removal and filling of H 2 to prevent Exatmosphere Turbo generator, monitoring of removal and filling of H 2 to prevent Exatmosphere Turbo generator, operation, to assure optimum efficiency Turbo generator, cooling gas control over expensive purge gases, minimize maintenance downtime, troubleshooting contamination problems Nuclear power, monitoring deuterium (D2) in air Nuclear power plant, vacuum drag recombiner after condenser Nuclear powerplant, propagation analysis of hydrogen in order to avoid an ignitable atmosphere...

 Open the catalog to page 6
Gas analyzer, transmitter TCD3000-7

APPLICATION SECTORS - EXTENDED INFORMATION Analysis of quenching gas spread in the locomotive Analysis of spread of hydrogen in plants and buildings Plants and buildings, propagation analysis of hydrogen in order to avoid an ignitable atmosphere Incoming goods inspection, Identification and quality of delivered gases, Quality insurance Impurity SF for discharge arc protection (GIS, Gas Insulated Switcher ) Soldering processes, Monitoring of Forming gas

 Open the catalog to page 7
Gas analyzer, transmitter TCD3000-8

Experts in hydrogen measurement Archigas GmbH Eisenstraße 3 D-65428 Rüsselsheim am Main Registry Court: Frankfurt am Main Register Nummer: HRB 119977 Tel: +49 (0)69 247544980

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.