Gas analyzer, transmitter TCD3000
8Pages

{{requestButtons}}

Catalog excerpts

Gas analyzer, transmitter TCD3000 - 1

Experts in hydrogen measurement

Open the catalog to page 1
Gas analyzer, transmitter TCD3000 - 2

The compact and robust transmitter TCD3000 is recommended for precise, fast and sensitive measurement of (quasi-) binary gas mixtures. Due to the stainless-steel housing and the IP67 protection class, the unit can be used safely in harsh environments. The unit is completely equipped with metal-to-metal connections, so that a high degree of tightness and pressure resistance over 200 bars can be guaranteed. The gas-carrying parts and the sensor are corrosion-resistant: The gas path is made of highgrade stainless steel 1.4404, The sensor on the gas side is completely glazed. In addition, the...

Open the catalog to page 2
Gas analyzer, transmitter TCD3000 - 3

SPECIFICATIONS Dimensions with connectors; weight Power supply Digital Output RS485 or TTL, Baud rate 19200 / Data 8bit Analog Output Ambient temperature range Flow rate Drift at zero point Error due to change of ambient temperature 0,8 - 200 bara / 700 bara on request Error due to change of pressure (above 800hPa)

Open the catalog to page 3
Gas analyzer, transmitter TCD3000 - 4

MEASUREMENT COMPONENTS AND RANGES Measuring Gas Basis Range Smallest Range

Open the catalog to page 4
Gas analyzer, transmitter TCD3000 - 5

GENERAL APPLICATION SECTORS APPLICATION SECTORS - EXTENDED INFORMATION Hydrogen as an impurity Impurities in Hydrogen (ring lines) Input to Argon refining process Hydrogen production via electrolysis Annealing furnace Oil & gas, petrochemicals, chemicals and synthetics Lower explosion level (LEL) upper explosion level (UEL) Air separators and pure gas production Blast furnace pig iron production “top gas” Detection of gas leakages Pharmacy Basic oxygen furnace (BOF) top blown furnace oxidation of carbon in molten pig iron using Food industry Metals, minerals, pulp and paper Direct reduced...

Open the catalog to page 5
Gas analyzer, transmitter TCD3000 - 6

APPLICATION SECTORS - EXTENDED INFORMATION Turbo generator, monitoring of removal and filling of H 2 to prevent Exatmosphere Turbo generator, monitoring of removal and filling of H 2 to prevent Exatmosphere Turbo generator, operation, to assure optimum efficiency Turbo generator, cooling gas control over expensive purge gases, minimize maintenance downtime, troubleshooting contamination problems Nuclear power, monitoring deuterium (D2) in air Nuclear power plant, vacuum drag recombiner after condenser Nuclear powerplant, propagation analysis of hydrogen in order to avoid an ignitable...

Open the catalog to page 6
Gas analyzer, transmitter TCD3000 - 7

APPLICATION SECTORS - EXTENDED INFORMATION Analysis of quenching gas spread in the locomotive Analysis of spread of hydrogen in plants and buildings Plants and buildings, propagation analysis of hydrogen in order to avoid an ignitable atmosphere Incoming goods inspection, Identification and quality of delivered gases, Quality insurance Impurity SF for discharge arc protection (GIS, Gas Insulated Switcher ) Soldering processes, Monitoring of Forming gas

Open the catalog to page 7
Gas analyzer, transmitter TCD3000 - 8

Experts in hydrogen measurement Archigas GmbH Eisenstraße 3 D-65428 Rüsselsheim am Main Registry Court: Frankfurt am Main Register Nummer: HRB 119977 Tel: +49 (0)69 247544980