video corpo

'Walk-in' Environmental and Temperature Testing chambers
12Pages

{{requestButtons}}

Catalog excerpts

'Walk-in' Environmental and Temperature Testing chambers - 1

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL ‘WALK-IN’ ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTIN

Open the catalog to page 1
'Walk-in' Environmental and Temperature Testing chambers - 2

FITOTERM FITOCLIMA TESTING ARALAB is a company specialized in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the environment, your own climate. FitoTerm & FitoClima temperature and humidity testing chambers offer highly...

Open the catalog to page 2
'Walk-in' Environmental and Temperature Testing chambers - 3

FITOTERM FITOCLIMA TESTING TEMPERATURE AND HUMIDITY CONTROL FITOTERM CHAMBERS – TEMPERATURE ONLY FITOTERM CHAMBERS TEMPERATURE RANGE HUMIDITY RANGE FITOCLIMA CHAMBERS – TEMPERATURE AND HUMIDITY CONTROL FITOTERM CHAMBERS TEMPERATURE RANGE HUMIDITY RANGE Note: EP, EC & ECP refer to the humidity sensors. EP = Electronic Psychrometric; EC = Electronic Capacitive; ECP = Electronic Capacitive + Psychrometric OTHER TECHNICAL CHARACTERISTICS FITOCLIMA / FITOTERM CHAMBERS Performance in CLIMATIC testing range | only FITOCLIMA chambers HEATING SPEED* COOLING SPEED* From 1ºC to 5ºC / minute Depending...

Open the catalog to page 3
'Walk-in' Environmental and Temperature Testing chambers - 4

FITOTERM FITOCLIMA TESTING DIMENSIONS AND DRAWINGS FITOTERM / FITOCLIMA 8.000 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) Standard refrigeration system is air cooled Services hub installation needs: 400VAC, 50Hz, 125A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 125A + N with 300mA differential ½” demineralized water supply 50mm water drain at floor level 3. Electrical cabinet installation needs: Supply power ECP20: Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential Single Phase electrical cable RV-K 5G16 on the top...

Open the catalog to page 4
'Walk-in' Environmental and Temperature Testing chambers - 5

FITOTERM FITOCLIMA TESTING DIMENSIONS AND DRAWINGS FITOTERM FITOCLIMA 12.000 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) Air cooled as an option (only ECP20 and ECP45) Services hub installation needs: 400VAC, 50Hz, 125A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 125A + N with 300mA differential ½” demineralized water supply 50mm water drain at floor level 3. Electrical cabinet installation needs: Water flow (at 20ºC): up to 5000 litres/hour (at -45 ºC models) 400VAC, 50Hz, 55A / 3-Phase + Neutral + Ground Electrical protection: Circuit...

Open the catalog to page 5
'Walk-in' Environmental and Temperature Testing chambers - 6

FITOTERM FITOCLIMA TESTING EQUIPMENT DESCRIPTION TEMPERATURE TEMPERATURE PRECISION (in the interior of the chamber, at 5 cm from walls, floor and top) • In Time ≤ ± 0,5º C • In Space ≤ ± 1,0º C TEMPERATURE SENSORS • One (1) PT 100 Class A, located in air treatment tunnel HEATING • By stainless steel electric heaters located in the air treatment tunnel COOLING • Mechanical compressor group Copeland Scroll (low noise, high efficiency) with enforced ventilation and without use of CFC’s. In -60ºC models water cooled condenser is used as standard. As an option the system can be cooled by an air...

Open the catalog to page 6
'Walk-in' Environmental and Temperature Testing chambers - 7

FITOTERM FITOCLIMA TESTING • Automatic stop function in case of water failure, with indication on the controller; High / Low Temperature alarms; High / Low humidity alarms; Interior: AISI 304 hermetical welded, vapor tight, stainless steel Exterior: Zinc mild steel with epoxy coating finish (color RAL 7035) Insulation: Rock Wool Interior illumination: Halogen lamp 12V (only available with optional window) Door: Double silicone joints and anti-condensation heating frames. Automatic electric locks with emergency opening from the inside • Air Flow: Forced through 2 blowers installed at the...

Open the catalog to page 7
'Walk-in' Environmental and Temperature Testing chambers - 8

FITOTERM FITOCLIMA TESTING CONTROLLER CLIMA PLUS V Programmable PLC exclusively developed for ARALAB chambers Programmable easy to use controller with Touch Screen Display (168 x 112mm) Resolution of 0.1ºC for Temperature and 0.1% for Relative Humidity High performance temperature and humidity control with value correction possibility in all ranges Capability for creating 50 programs of 50 segments each Non-volatile memory Automatic restart of tests due to power failure, without losing data and restarting test where it was interrupted Real-time monitoring of all functions and control of...

Open the catalog to page 8
'Walk-in' Environmental and Temperature Testing chambers - 9

FITOTERM FITOCLIMA TESTING FITOLOG SOFTWARE The FitoLog software pack is a set of applications designed to facilitate the managing, monitoring and recording of programs and data from the FitoClima chambers. It consists of 3 applications: FitoLog, FitoLogView and FitoProgram. FITOLOG Records and displays in real time all data and details related to the set-points, running variables and equipment behaviour. It also retrieves information about the active components of the chamber, running processes, errors, alarms and allows the configuration of periodic or alarm triggered remote notifications...

Open the catalog to page 9
'Walk-in' Environmental and Temperature Testing chambers - 10

FITOTERM FITOCLIMA TESTING MOST COMMON OPTIONAL ACCESSORIES PLEASE CONSULT ARALAB FOR OTHER ITEMS FitoLog software pack Wireless and Ethernet connections for PC running FitoLog software Observational anti condensation windows in multi layered glass Water demineralizer (for FitoClima Chambers) Water conductivity monitor (for FitoClima Chambers) Additional entry ports Temperature and Humidity calibration certificate from accredited external laboratory ISO 17025 calibrations Faster heating / cooling temperature change rates Shaker/Slip table integration for climatic and vibration testing...

Open the catalog to page 10
'Walk-in' Environmental and Temperature Testing chambers - 11

FITOTERM FITOCLIMA TESTING INSTALLATION REQUIREMENTS To ensure a correct functioning of the chamber, the following installation conditions are required: INSTALLATION SITE The place should be easily accessible, according to equipment dimensions and weight. It should have good air circulation and a room temperature between 10º and 26ºC. The floor should be leveled and a minimum distance of 50cm from the walls and other equipment must be kept. ELECTRICAL SUPPLY Near the equipment with the specified requirements: 3/N/PE AC 400V 10%; 50Hz. Amperage will vary with specific requirements of...

Open the catalog to page 11

All Aralab catalogs and technical brochures