TESTING TESTA TT TESTA CT TEMPERATURE TESTING CLIMATIC TESTING ‘WALK-IN’ ENVIRONMENTAL TEST CHAMBER

 Open the catalog to page 1
'Walk-in' Environmental and Temperature Testing chambers-2

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS ARALAB is a company specialized in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the Environment. Your Own Climate. TESTA Walk-in temperature and humidity testing chambers...

 Open the catalog to page 2
'Walk-in' Environmental and Temperature Testing chambers-3

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS WALK-IN ENVIRONMENTAL TEST CHAMBER TEMPERATURE / HUMIDITY CONTROL ‘WALK-IN’ ENVIRONMENTAL CHAMBER

 Open the catalog to page 3
'Walk-in' Environmental and Temperature Testing chambers-4

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS 10 * Please inform Aralab about the application or testing standard so we can provide with the most adequate solution. Aralab Testing chambers are configured and factory calibrated to comply with the necessary heating / cooling speed requirements. TEMPERATURE / HUMIDITY CONTROL ‘WALK-IN’ ENVIRONMENTAL CHA

 Open the catalog to page 4
'Walk-in' Environmental and Temperature Testing chambers-5

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS EXTERNAL DIMENSIONS (HxWxD) (mm) 4. 0 Standard water cooled: Water flow (at 25 °C): up to 5000 litres/hour (for 40 °C models) up to 10000 litres/hour (for 60 °C models) Water entry and exit pipe: 1” or 28mm Differential pressure between entry and exit: > 2,5 bars Maximum temperature of water entry: 26 °C Minimum temperature of water entry: 16 °C Recommended temperature of water entry: 18 °C 1. Standard refrigeration system is air cooled 2.0 Services hub installation needs: 0 %” demineralized water supply 0 50mm water drain at floor level 3....

 Open the catalog to page 5
'Walk-in' Environmental and Temperature Testing chambers-6

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS I6] 1. Air cooled as an option (only ECP20 and ECP45)2. 0 Services hub installation needs: # %” demineralized water supply # 50mm water drain at floor level 3. Electrical cabinet installation needs:Supply power ECP40: 400VAC, 50Hz, 80A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 80A + N with 300mA differential Supply power ECP60: 400VAC, 50Hz, 125A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 125A + N with 300mA differential # RS232 or RJ45 communications port4. # Standard water cooled:...

 Open the catalog to page 6
'Walk-in' Environmental and Temperature Testing chambers-7

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS I7] TEMPERATURETEMPERATURE SENSORS One (1) PT 100 Class A, located in air treatment tunnel One (1) PT 100 Class A, movable sensors for flexible placing inside chamber By stainless steel electric heaters located in the air treatment tunnel Mechanical compressor group Scroll (low noise, high efficiency) with enforced ventilation and without use of CFC's. In -60°C models water cooled condenser is used as standard. As an option the system can be cooled by an air condenser. Safety thermostats with High / Low temperature configuration, with automatic...

 Open the catalog to page 7
'Walk-in' Environmental and Temperature Testing chambers-8

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS • Automatic stop function in case of water failure, with indication on the controller; High / Low Temperature alarms; High / Low humidity alarms; Interior: AISI 304 hermetical welded, vapor tight, stainless steel Exterior: Zinc mild steel with epoxy coating finish (color RAL 7035) Insulation: Rock Wool Interior illumination: Halogen lamp 12V (only available with optional window) Door: Double silicone joints and anti-condensation heating frames. Automatic electric locks with emergency opening from the inside • Air Flow: Forced through 2 blowers...

 Open the catalog to page 8
'Walk-in' Environmental and Temperature Testing chambers-9

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS Programmable PLC exclusively developed for ARALAB chambers Easy to use coloured Touch-Screen Display Interface Resolution of 0,1°C for Temperature and 0,1% for Relative Humidity High performance temperature and humidity control with value correction in all ranges Capability for creating 50 programs of 50 segments each Internal non volatile memory for storing test data Automatic restart of tests due to power failure, without losing data and restarting test where it was interrupted Real-time monitoring of all functions and control of equipment....

 Open the catalog to page 9
'Walk-in' Environmental and Temperature Testing chambers-10

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS FITOLOG SOFTWARE The FitoLog software pack is a set of applications designed to facilitate the managing, monitoring and recording of programs and data from the TESTA chambers. It consists of 3 applications: FitoLog, FitoLogView and FitoProgram. FITOLOG Records and displays in real time all data and details related to the set-points, running variables and equipment behaviour. It also retrieves information about the active components of the chamber, running processes, errors, alarms and allows the configuration of periodic or alarm triggered...

 Open the catalog to page 10
'Walk-in' Environmental and Temperature Testing chambers-11

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS COMMON ACCESSORIES PLEASE CONSULT ARALAB FOR OTHER ITEMS FitoLog and FitoLogView Software pack Anti-condensation observation window in multi layered glass Water demineralizer Water conductivity monitor Additional entry side-ports Calibration certificates from accredited external laboratory Heating / Cooling temperature change rate speeds Door with observation window Additional Entry-ports Water Treatment systems Electronic safety locks Atex and safety protections Water supply tank TEMPERATURE / HUMIDITY CONTROL ‘WALK-IN’ ENVIRONMENTAL CHAMBER...

 Open the catalog to page 11
'Walk-in' Environmental and Temperature Testing chambers-12

TESTA WALK-IN - TEMPERATURE & ENVIRONMENTAL CHAMBERS INSTALLATION REQUIREMENTS To ensure a correct functioning of the chamber, the following installation conditions are required: INSTALLATION SITE The place should be easily accessible, according to equipment dimensions and weight. It should have good air circulation and a room temperature between 10º and 26ºC. The floor should be leveled and a minimum distance of 50cm from the walls and other equipment must be kept. ELECTRICAL SUPPLY Near the equipment with the specified requirements: 3/N/PE AC 400V 10%; 50Hz. Amperage will vary with specific...

 Open the catalog to page 12