Product catalog summary
Overview: TESTA environmental test chambers, manufactured by ARALAB, are designed for precise temperature and humidity control, suitable for industries such as electronics, automotive, and aerospace. These chambers are built with high-quality components to ensure durability and compliance with international standards.
Key Features:
  • Advanced climate control technology ensures uniform climatic conditions through internal aerodynamic optimization.
  • Automatic testing programs enhance efficiency.
  • Durable stainless steel interior with adjustable shelves.
  • Environmentally friendly construction.
  • Compliance with EN, IEC, DIN, ISO, NP, and UNE standards.
Applications: Suitable for environmental testing, research and development, quality control, and production facilities.
Certifications: Certified with ISO:9001 for Quality Management and ISO:14001 for Environmental Management.
Models and Specifications:
  • TESTA TT Chambers: Temperature range from -52°C to +180°C or -75°C to +180°C, without humidity control.
  • TESTA CT Chambers: Temperature range from 10°C to 95°C, humidity range from 10% RH to 98% RH.
  • Temperature uniformity ranges from ±0.1°C to ±1.5°C depending on the model and conditions.
  • Temperature change rates for heating and cooling can reach up to 10K/minute.
Technical Data:
  • Noise levels range from 55 to 64 dBA.
  • Power supply requirements vary by model, with options for air or water-cooled refrigeration systems.
  • Refrigerants used include R449A and R23.
Performance and Dimensions:
  • Chambers are available in various sizes, with internal volumes ranging from 272 liters to 967 liters.
  • Standard features include two shelves with a maximum load of 25 kg per shelf, and one entry port with an 80 mm diameter.
Specifications: Operate on a 3-phase electrical system with a 400VAC, 50Hz supply, including a circuit breaker with 300mA differential protection and RV-K electrical cables. Equipped with RJ45 communication ports.
Temperature and Humidity Performance: Temperature range from -75°C to 180°C, with humidity from 10% to 98% RH, controlled according to IEC60068-3-5 standards.
Dimensions and Capacity: Test space volume ranges from 1411 to 2000 liters, with two stainless steel shelves included as standard, each with a weight capacity of 50 kg.
Power and Refrigeration: Use either air or water-cooled refrigeration systems, with nominal power requirements ranging from 17 kW to 44 kW. Refrigerants include R449A and R23.
Construction and Security: Interior made of stainless steel, exterior of zinc mild steel with epoxy coating. Security features include automatic stop functions, high/low temperature alarms, and a safety thermostat.
Control Systems: The ClimaPlus HMI controller offers a user-friendly interface with programmable settings for temperature and humidity, supporting remote access and data management through the FitoLog software suite.
Accessories and Applications: Optional accessories include observation windows, additional entry ports, and testing integrations such as vibration and solar simulation, designed for a wide range of environmental testing applications.
See more

Catalog excerpts

Testa - Reach-in Temperature and Environmental Chambers-1

TESTING TESTA TT TESTA CT TEMPERATURE TESTING CLIMATIC TESTING ‘REACH-IN’ ENVIRONMENTAL TEST CHAMBER

 Open the catalog to page 1
Testa - Reach-in Temperature and Environmental Chambers-2

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS ARALAB is a company specialised in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the Environment. Your Own Climate. TESTA temperature and humidity testing chambers offer highly...

 Open the catalog to page 2
Testa - Reach-in Temperature and Environmental Chambers-3

BPPPHBBBiNEttHBBBBBBB Er^ilBBBP'JTPHl...” t MUBBBiNintnnB ■■■rtfif gprrai iiinimmnru !■■ ■ ■■-ftgf iflUKi nisriiiiiiiticrT iii ■■■■■■}[uul iiiriini.ir-.n lift ■■■■■be^Se^s ■■■■■■■■■■■ an^i ;iiiiii^iijl|

 Open the catalog to page 3
Testa - Reach-in Temperature and Environmental Chambers-4

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 10 TESTA CHAMBERS - MODELS AND REFERENCES • • • • TESTA TT CHAMBERS - TEMPERATURE ONLY TESTA TT CHAMBERS • • • • TESTA CT CHAMBERS - TEMPERATURE AND HUMIDITY TESTA CT CHAMBERS EC - models with Capacitive humidity sensor EP - models with Psychrometric humidity sensor ECP - models with both Capacitive and Psychrometric humidity sensors. Please consult Aralab if in doubt about the type of sensor to chose RANGES FOR CLIMATIC AND TEMPERATURE TESTING • • • • TESTA CT TESTING CHAMBERS Performance in CLIMATIC testing range | only TESTA CT chambers TEMPERATURE...

 Open the catalog to page 4
Testa - Reach-in Temperature and Environmental Chambers-5

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS • • • • SYSTEM STRUCTURE 6. Observation Window (optional) 8. Touch screen controller aralab ‘REACH-IN’ ENVIRONMENTAL TEST CHAMBERS

 Open the catalog to page 5
Testa - Reach-in Temperature and Environmental Chambers-6

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 300 - PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 300 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2403 1865 1840 According to castor wheel levelling 1. Standard refrigeration system is air cooled Supply power TESTA 300 TT/CT 75: 2. Services hub installation needs: ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 32A + N with 30mA differential 50mm water drain at floor level 3. Water cooled option (is included as standard in -75ºC models) Supply power...

 Open the catalog to page 6
Testa - Reach-in Temperature and Environmental Chambers-7

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS I7] TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range in Space @ low temp. point ± 0,2 ± 0,2 in Space @ high temp point Temperature fluctuation in time Temperature change rate (2a) Qb) PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Type of Refrigeration (air or water cooled ) Water Optional Standard Performances measured...

 Open the catalog to page 7
Testa - Reach-in Temperature and Environmental Chambers-8

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 500 PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 500 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2456 1470 1450 According to castor wheel leveling 1990 1960 According to castor wheel leveling 1. Standard refrigeration system is air cooled Supply power TESTA 500 TT/CT 75: 2. Services hub installation needs: ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 32A + N with 300mA differential 50mm water drain at floor level 3. Electrical cabinet installation...

 Open the catalog to page 8
Testa - Reach-in Temperature and Environmental Chambers-9

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range in Space @ low temp. point °C in Space @ high temp point °C Temperature fluctuation in time °C Temperature change rate Qa) (2b) cooling K/min heating K/min PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Type of Refrigeration (air or water cooled ) Performances measured...

 Open the catalog to page 9
Testa - Reach-in Temperature and Environmental Chambers-10

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 1.000 PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 1.000 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2755 1350 1330 According to caster wheel leveling 2060 2030 According to caster wheel leveling 1. Standard refrigeration system is air cooled Supply power TESTA 1000 TT/CT 75 and 10K model: 2. Services hub installation needs: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential...

 Open the catalog to page 10
Testa - Reach-in Temperature and Environmental Chambers-11

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS l11] TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range 180 180 Temperature uniformity0 in Space @ low temp. point in Space @ high temp point ± 1,4 PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf kg Entry ports Included as standard (more can be added) Diameter (other diameters available) Weight (approximately) POWER & REFRIGERATION Nominal Power Type of Refrigeration (air or water cooled )Air Standard N/A Water Optional Standard...

 Open the catalog to page 11
Testa - Reach-in Temperature and Environmental Chambers-12

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 0 1. Standard refrigeration system is air cooled2. Services hub installation needs: 0 %” demineralized water supply Condutivity: <50pS/cm , TDS <35PPM 0 50mm water drain at floor level 3. • Electrical cabinet installation needs:Supply power TESTA 1500 TT/CT 50: 400VAC, 50Hz, 32A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 32A + N with 300mA differential Supply power TESTA 1500 TT/CT 75: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential # RJ45 communications...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.