1. Catalogs
  2. Aralab
  3. FitoClima 300 CB - Cold bend testing chamber
video corpo

FitoClima 300 CB - Cold bend testing chamber

FitoClima 300 CB - Cold bend testing chamber
1 / 12 PagesView full catalog

FitoClima 300 CB - Cold bend testing chamber

Product catalog summary
Overview
TESTA environmental chambers are designed for precise climatic and temperature testing, particularly for cold bend and cold impact testing of wires and cables. Manufactured by Aralab, these chambers offer advanced climate control technology and are compliant with international standards such as EN, IEC, DIN, ISO, NP, and UNE.

Key Features
  • Advanced climate control technology ensuring uniform conditions.
  • Durable stainless steel interior with adjustable shelves.
  • Non-polluting construction and cooling system.
  • Time-saving features with programmable testing programs.

Applications
  • Environmental testing across various industries including electronics, automotive, aerospace, and military equipment.
  • Quality control and production facilities.

Specifications
  • Temperature range for TESTA TT chambers: -75ºC to +180ºC.
  • Temperature and humidity range for TESTA CT chambers: -75ºC to +180ºC and 10% RH to 98% RH.
  • Temperature uniformity and fluctuation are tightly controlled.
  • Noise level ranges from 55 to 64 dBA.

Technical Details
  • Temperature precision within ± 0.5ºC in time and ± 1.5ºC in space.
  • Humidity precision within ± 1.0% RH in time and ± 2.5% RH in space.
  • Equipped with PT 100 Class A temperature sensors and various humidity sensors.
  • Programmable winding mechanism with automatic stop and speed control.

Controller and Software
  • CLIMA PLUS controller with a touch-screen interface and real-time monitoring.
  • FitoLog software for data management and diagnostics.

Installation Requirements
  • Site should have good air circulation and a room temperature between 10º and 26ºC.
  • Electrical supply should meet specified requirements.
  • Water circuits for humidification and cooling require specific pressure and temperature conditions.

Additional Accessories
  • Observation windows, water demineralizers, air dryers, and calibration certificates available.
  • Optional faster heating/cooling rates and UV/sun radiation aging simulators.
See more

Catalog excerpts

FitoClima 300 CB - Cold bend testing chamber-1

TESTING TESTA CT/TT 300 CR ENVIRONMENTAL CHAMBER FOR COLD BEND / COLD IMPACT TESTING OF WIRES & CABLES

 Open the catalog to page 1
FitoClima 300 CB - Cold bend testing chamber-2

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS ARALAB is a company specialised in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the environment, Your own climate. TESTA temperature and humidity testing chambers offer highly...

 Open the catalog to page 2
FitoClima 300 CB - Cold bend testing chamber-3

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS ©H Performances measured in factory with ambient temperatures between 20°C and 25°C. (1a) Measurements at center of test space, with empty chamber and no optional accessories; (1b) in temperature range up to 150°C; (2a) According to IEC/EN 60068-3-5. Values will vary with TESTA CT/TESTA TT model, internal volume, compressor type and condenser cooling system. Temperature rate of change can be adjusted to comply with the needed heating / cooling speed requirements. Optional accessories are available for more demanding heating and cooling temperature...

 Open the catalog to page 3
FitoClima 300 CB - Cold bend testing chamber-4

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 10 1. Standard refrigeration system is air cooled2. Services hub installation needs: 0 V2” demineralized water supply 0 50mm water drain at floor level 3. # Electrical cabinet installation needs:Supply power ECP20: 230VAC, 50Hz, 16A / Single Phase + Neutral + Ground Electrical protection: Circuit breaker 16A + N with 300mA differential Single Phase electrical cable RV-K 3G2,5 on the top Supply power ECP45: 400VAC, 50Hz, 16A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 16A + N with 300mA differential Supply power ECP75: 400VAC,...

 Open the catalog to page 4
FitoClima 300 CB - Cold bend testing chamber-5

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS EQUIPMENT DESCRIPTION TEMPERATURE TEMPERATURE PRECISION (in the interior of the chamber, at 5 cm from walls, floor and top) • In Time ≤ ± 0,5ºC • In Space ≤ ± 1,5ºC TEMPERATURE SENSORS • One (1) PT 100 Class A, located in air treatment tunnel • One (1) PT 100 Class A, movable sensor for flexible placing inside chamber HEATING • By tubular stainless steel electric heaters located in the air treatment tunnel COOLING • Air cooled hermetic scroll compressor group (low noise and high efficiency) with enforced ventilation and without CFC’s. Water-cooled...

 Open the catalog to page 5
FitoClima 300 CB - Cold bend testing chamber-6

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS • Automatic stop function in case of water failure, with indication on the controller; High / Low Temperature alarms; High / Low humidity alarms. Interior: AISI 304 hermetical welded, vapour tight, stainless steel Exterior: Zinc mild steel with epoxy coating finish (color RAL 7035) Insulation: Rock Wool Interior illumination: Halogen lamp 12V (only available with optional window) Door: Double silicone joints and anti-condensation heating frames (optional window) Reinforced Floor Plate • Air Flow: Forced through 1 ventilator/fan. • Air Renovation: By...

 Open the catalog to page 6
FitoClima 300 CB - Cold bend testing chamber-7

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS PROGRAMABLE WINDING MECHANISM WITH 6 MANDRELS ENVIRONMENTAL CHAMBER FOR COLD BEND / COLD IMPACT TESTING OF WIRES & CABLES

 Open the catalog to page 7
FitoClima 300 CB - Cold bend testing chamber-8

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS CONTROLLER CLIMA PLUS Programmable PLC exclusively developed for ARALAB chambers Easy to use coloured Touch-Screen Display Interface Resolution of 0,1ºC for Temperature and 0,1% for Relative Humidity High performance temperature and humidity control with value correction in all ranges Capability for creating 50 programs of 50 segments each Internal non volatile memory for storing test data Automatic restart of tests due to power failure, without losing data and restarting test where it was interrupted Real-time monitoring of all functions and control...

 Open the catalog to page 8
FitoClima 300 CB - Cold bend testing chamber-9

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS FITOLOG SOFTWARE The FitoLog software pack is a set of applications designed to facilitate the managing, monitoring and recording of programs and data from the TESTA chambers. It consists of 3 applications: FitoLog, FitoLogView and FitoProgram. FITOLOG Records and displays in real time all data and details related to the set-points, running variables and equipment behaviour. It also retrieves information about the active components of the chamber, running processes, errors, alarms and allows the configuration of periodic or alarm triggered remote notifications...

 Open the catalog to page 9
FitoClima 300 CB - Cold bend testing chamber-10

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS COMMON ACCESSORIES PLEASE CONSULT ARALAB FOR OTHER ITEMS Software pack FitoLog and FitoLogView Observation anti-condensation windows in multi layered glass Water demineralizer (for TESTA CT Chambers) Integrated water tank Air dryer Additional entry ports Calibration certificate from accredited external laboratory Faster heating / cooling temperature change rates up to 10k/minute WINDOW OPTION The observation window is composed of a multilayered glass with optimum levels of thermal insulation. The interior and exterior glasses have a heating system...

 Open the catalog to page 10
FitoClima 300 CB - Cold bend testing chamber-11

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS INSTALLATION REQUIREMENTS INSTALLATION SITE The place should be easily accessible, according to equipment dimensions and weight. It should have good air circulation and a room temperature between 10º and 26ºC. The floor should be leveled and a minimum distance of 50cm from the walls and other equipment must be kept. ELECTRICAL SUPPLY Near the equipment with the specified requirements. HUMIDIFICATION CIRCUIT AND DEMINERALIZED WATER (FOR TESTA CT MODELS) The humidification circuit works exclusively with distilled or demineralized water. For this circuit,...

 Open the catalog to page 11
FitoClima 300 CB - Cold bend testing chamber-12

Let’s meet! [email protected] www.aralab.pt T: +351 219 154 960 Control the environment Your own climate

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.