TESTING TESTA TT TESTA CT TEMPERATURE / HUMIDITY CONTROL ‘REACH-IN’ ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTIN
Open the catalog to page 1TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS ARALAB is a company specialised in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the environment, Your own climate. TESTA temperature and humidity testing chambers offer...
Open the catalog to page 2TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TEMPERATURE AND HUMIDITY CONTROL RANGES TESTA TT Chambers – Temperature only TESTA TT CHAMBERS TEMPERATURE RANGE HUMIDITY RANGE TESTA CT Chambers – Temperature and Humidity TESTA CT CHAMBERS TEMPERATURE RANGE HUMIDITY RANGE TEMPERATURE AND HUMIDITY CONTROL RANGES TESTA CT TESTING CHAMBERS Performance in CLIMATIC testing range | only TESTA CT chambers TEMPERATURE RANGE TEMPERATURE UNIFORMITY HUMIDITY RANGE Performance in TEMPERATURE testing | TESTA TT and TESTA CT chambers TEMPERATURE RANGE TEMPERATURE RATE OF CHANGE HEATING (2a) (2b) TEMPERATURE...
Open the catalog to page 3TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS SYSTEM STRUCTURE Main switch DB9 connector Safety thermostat Powerhouse Machinery compartment Test chamber Sensors Entry points Interior Light Touch screen controller ‘REACH-IN’ ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTIN
Open the catalog to page 4TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 300 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) Standard refrigeration system is air cooled Services hub installation needs: 400VAC, 50Hz, 50A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential ½” demineralized water supply 50mm water drain at floor level 3. Electrical cabinet installation needs: 4. Water cooled option: 230VAC, 50Hz, 16A / Single Phase + Neutral + Ground Electrical protection: Circuit breaker 16A + N with 300mA...
Open the catalog to page 5TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 500 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) Standard refrigeration system is air cooled Services hub installation needs: 400VAC, 50Hz, 50A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential ½” demineralized water supply 50mm water drain at floor level 3. Electrical cabinet installation needs: 4. Water cooled option: Electrical protection: Circuit breaker 3 x 16A + N with 300mA differential Single Phase electrical cable RV-K...
Open the catalog to page 6TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS TESTA TT TESTA CT 1.000 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) Standard refrigeration system is air cooled Services hub installation needs: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential ½” demineralized water supply 50mm water drain at floor level 3. Electrical cabinet installation needs: 4. Water cooled option: Electrical protection: Circuit breaker 3 x 25A + N with 300mA differential Single Phase electrical cable RV K...
Open the catalog to page 7TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS TESTA TT TESTA CT 1.500 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) Standard refrigeration system is air cooled Services hub installation needs: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential ½” demineralized water supply 50mm water drain at floor level 3. Electrical cabinet installation needs: 4. Water cooled option: Electrical protection: Circuit breaker 3 x 25A + N with 300mA differential Single Phase electrical cable RV K...
Open the catalog to page 8TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS EQUIPMENT DESCRIPTION Temperature Temperature Precision (in the interior of the chamber, at 5 cm from walls, floor and top) • In Time ≤ ± 0,5ºC • In Space ≤ ± 1,5ºC Temperature Sensors • One (1) PT 100 Class A, located in air treatment tunnel • One (1) PT 100 Class A, movable sensors for flexible placing inside chamber Heating • By tubular stainless steel electric heaters located in the air treatment tunnel Cooling • Air cooled hermetic scroll compressor group (low noise and high efficiency) with enforced ventilation and without CFC’s....
Open the catalog to page 9TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS • Automatic stop function in case of water failure, with indication on the controller; High / Low Temperature alarms; High / Low humidity alarms. Interior: AISI 304 hermetical welded, vapour tight, stainless steel Exterior: Zinc mild steel with epoxy coating finish (color RAL 7035) Insulation: Rock Wool Interior illumination: Halogen lamp 12V (only available with optional window) Door: Double silicone joints and anti-condensation heating frames (optional window) • Air Flow: Forced through 1 or 2 ventilators/fans (300 and 500 models have one...
Open the catalog to page 10TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS CONTROLLER clima plus Programmable PLC exclusively developed for ARALAB chambers Easy to use coloured Touch-Screen Display Interface Resolution of 0,1ºC for Temperature and 0,1% for Relative Humidity High performance temperature and humidity control with value correction in all ranges Capability for creating 50 programs of 50 segments each Internal non volatile memory for storing test data Automatic restart of tests due to power failure, without losing data and restarting test where it was interrupted Real-time monitoring of all functions and...
Open the catalog to page 11All Aralab catalogs and technical brochures
-
Temperature Shock test chamber
10 Pages
-
Curing chambers - 600/1200 PHCI
10 Pages
-
FitoTerm 150 CT2-80
10 Pages
-
FITOCLIMA WALK-IN BIO
13 Pages
-
FITOCLIMA 600 & 1200 STABILITY
11 Pages
-
Stability rooms
12 Pages
-
FITOCLIMA 600 & 1200 STABILITY
11 Pages
-
FITOCLIMA 600 & 1200 BIO
11 Pages
-
FitoClima HP 'walk-in'
11 Pages
-
FITOCLIMA WALK-IN PL/PLH
13 Pages
-
MULTI-TIER PLANT GROWTH ROOMS
13 Pages
-
SINGLE-TIER PLANT GROWTH ROOMS
11 Pages
-
FitoClima 600 PDH
8 Pages