1. Catalogs
  2. Aralab
  3. Environmental and Temperature 'reach-in' Chambers
video corpo

Environmental and Temperature 'reach-in' Chambers

Environmental and Temperature 'reach-in' Chambers
1 / 22 PagesView full catalog

Environmental and Temperature 'reach-in' Chambers

Product catalog summary
Overview
TESTA temperature and humidity testing chambers, manufactured by ARALAB, are designed for precise climatic and temperature testing across various industries. They feature high-quality components for optimal performance in research and testing.
Key Features
  • Advanced climate control technology.
  • Internal aerodynamic optimization for uniform conditions.
  • Configurable testing programs for automatic operation.
  • Durable stainless steel interior with adjustable shelves.
  • Environmentally friendly construction and cooling system.
  • Compliance with international standards (EN, IEC, DIN, ISO, NP, UNE).
Applications
  • Environmental testing in industries such as Electronics, Automotive, Aerospace, Building Materials, and Military Equipment.
  • Used in Research & Development, Quality Control, and Production Facilities.
Certifications
  • ISO:9001 for Quality Management System.
  • ISO:14001 for Environmental Management System.
Models and Specifications
  • TESTA TT Chambers: Temperature range from -52ºC to +180ºC.
  • TESTA CT Chambers: Temperature range from 10ºC to 95ºC, Humidity range from 10% RH to 98% RH.
  • Temperature uniformity and rate of change vary by model and configuration.
Technical Data
  • Noise levels range from 55 to 64 dBA.
  • Performance measured at ambient temperatures between 20ºC and 25ºC.
  • Various models offer different cooling and heating rates.
Dimensions and Installation
  • External and internal dimensions vary by model (e.g., TESTA 300, 500, 1,000, 1,500).
  • Standard refrigeration is air-cooled, with water-cooled options available.
  • Electrical and water supply requirements specified for each model.
Performance Metrics
  • Temperature and humidity testing capabilities detailed for each model.
  • Uniformity and fluctuation metrics provided for temperature and humidity.
  • Power and refrigeration specifications include supply voltage and nominal power.
Specifications
The chambers operate on a 3-phase electrical system with a 400VAC, 50Hz supply, include a circuit breaker with 300mA differential protection, and use RV-K electrical cables. They are equipped with RJ45 communication ports.
Temperature and Humidity Performance
The chambers offer a temperature range from -75°C to 180°C, with temperature uniformity varying slightly depending on the model. Humidity ranges from 10% to 98% relative humidity, with uniformity and fluctuation controlled according to IEC60068-3-5 standards.
Dimensions and Capacity
The test space volume ranges from 1411 to 2000 liters, with two shelves included as standard, each capable of supporting up to 50 kg. Additional entry ports and shelves can be added.
Power and Refrigeration
The chambers use either air or water-cooled refrigeration systems, with nominal power requirements ranging from 17 kW to 44 kW. Refrigerants used include R449A and R23.
Construction and Security
The chambers are constructed with stainless steel interiors and zinc mild steel exteriors. They feature safety thermostats, high/low temperature alarms, and automatic stop functions for security.
Control Systems
The ClimaPlus HMI controller offers a user-friendly interface with programmable settings, real-time monitoring, and remote access capabilities. The FitoLog software suite aids in data management and diagnostics.
Accessories and Applications
Optional accessories include observation windows, additional entry ports, and various testing integrations such as vibration and solar simulation.
See more

Catalog excerpts

Environmental and Temperature 'reach-in' Chambers-1

TESTING TESTA TT TESTA CT TEMPERATURE TESTING CLIMATIC TESTING ‘REACH-IN’ ENVIRONMENTAL TEST CHAMBER

 Open the catalog to page 1
Environmental and Temperature 'reach-in' Chambers-2

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS ARALAB is a company specialised in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the Environment. Your Own Climate. TESTA temperature and humidity testing chambers offer highly...

 Open the catalog to page 2
Environmental and Temperature 'reach-in' Chambers-3

BPPPHBBBiNEttHBBBBBBB Er^ilBBBP'JTPHl...” t MUBBBiNintnnB ■■■rtfif gprrai iiinimmnru !■■ ■ ■■-ftgf iflUKi nisriiiiiiiticrT iii ■■■■■■}[uul iiiriini.ir-.n lift ■■■■■be^Se^s ■■■■■■■■■■■ an^i ;iiiiii^iijl|

 Open the catalog to page 3
Environmental and Temperature 'reach-in' Chambers-4

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 10 TESTA CHAMBERS - MODELS AND REFERENCES • • • • TESTA TT CHAMBERS - TEMPERATURE ONLY TESTA TT CHAMBERS • • • • TESTA CT CHAMBERS - TEMPERATURE AND HUMIDITY TESTA CT CHAMBERS EC - models with Capacitive humidity sensor EP - models with Psychrometric humidity sensor ECP - models with both Capacitive and Psychrometric humidity sensors. Please consult Aralab if in doubt about the type of sensor to chose RANGES FOR CLIMATIC AND TEMPERATURE TESTING • • • • TESTA CT TESTING CHAMBERS Performance in CLIMATIC testing range | only TESTA CT chambers TEMPERATURE...

 Open the catalog to page 4
Environmental and Temperature 'reach-in' Chambers-5

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS DIMENSIONS AND DRAWINGS • • • • SYSTEM STRUCTURE 6. Observation Window (optional) 8. Touch screen controller aralab ‘REACH-IN’ ENVIRONMENTAL TEST CHAMBERS

 Open the catalog to page 5
Environmental and Temperature 'reach-in' Chambers-6

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 300 - PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 300 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2403 1865 1840 According to castor wheel levelling 1. Standard refrigeration system is air cooled Supply power TESTA 300 TT/CT 75: 2. Services hub installation needs: ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 32A + N with 30mA differential 50mm water drain at floor level 3. Water cooled option (is included as standard in -75ºC models) Supply power...

 Open the catalog to page 6
Environmental and Temperature 'reach-in' Chambers-7

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS I7] TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range in Space @ low temp. point ± 0,2 ± 0,2 in Space @ high temp point Temperature fluctuation in time Temperature change rate (2a) Qb) PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Type of Refrigeration (air or water cooled ) Water Optional Standard Performances measured...

 Open the catalog to page 7
Environmental and Temperature 'reach-in' Chambers-8

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 500 PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 500 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2456 1470 1450 According to castor wheel leveling 1990 1960 According to castor wheel leveling 1. Standard refrigeration system is air cooled Supply power TESTA 500 TT/CT 75: 2. Services hub installation needs: ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 32A + N with 300mA differential 50mm water drain at floor level 3. Electrical cabinet installation...

 Open the catalog to page 8
Environmental and Temperature 'reach-in' Chambers-9

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range in Space @ low temp. point °C in Space @ high temp point °C Temperature fluctuation in time °C Temperature change rate Qa) (2b) cooling K/min heating K/min PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf Entry ports Included as standard (more can be added) Diameter (other diameters available) POWER & REFRIGERATION Type of Refrigeration (air or water cooled ) Performances measured...

 Open the catalog to page 9
Environmental and Temperature 'reach-in' Chambers-10

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS TESTA 1.000 PERFORMANCES, DIMENSIONS AND DRAWINGS TESTA TT / TESTA CT 1.000 EXTERNAL DIMENSIONS (HxWxD) (mm) INTERNAL DIMENSIONS (HxWxD) (mm) MINIMUM CLEARANCE MAINTENANCE AREA 2755 1350 1330 According to caster wheel leveling 2060 2030 According to caster wheel leveling 1. Standard refrigeration system is air cooled Supply power TESTA 1000 TT/CT 75 and 10K model: 2. Services hub installation needs: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground ¾” demineralized water supply Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential...

 Open the catalog to page 10
Environmental and Temperature 'reach-in' Chambers-11

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS l11] TESTA CHAMBERS PERFORMANCE PERFORMANCE IN TEMPERATURE TESTING Temperature range 180 180 Temperature uniformity0 in Space @ low temp. point in Space @ high temp point ± 1,4 PERFORMANCE IN HUMIDITY TESTING Humidity range Test space volume number of shelves included (more can be added) maximum weight load per shelf kg Entry ports Included as standard (more can be added) Diameter (other diameters available) Weight (approximately) POWER & REFRIGERATION Nominal Power Type of Refrigeration (air or water cooled )Air Standard N/A Water Optional Standard...

 Open the catalog to page 11
Environmental and Temperature 'reach-in' Chambers-12

TESTA - TEMPERATURE & ENVIRONMENTAL CHAMBERS 0 1. Standard refrigeration system is air cooled2. Services hub installation needs: 0 %” demineralized water supply Condutivity: <50pS/cm , TDS <35PPM 0 50mm water drain at floor level 3. • Electrical cabinet installation needs:Supply power TESTA 1500 TT/CT 50: 400VAC, 50Hz, 32A / 3-Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 32A + N with 300mA differential Supply power TESTA 1500 TT/CT 75: 400VAC, 50Hz, 50A / 3 Phase + Neutral + Ground Electrical protection: Circuit breaker 3 x 63A + N with 300mA differential # RJ45 communications...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.