Cigar rolling machine - Case study-1

Cigar rolling machine Before Blaster: BL60 Air volume: Less than 4-6 m3/min Low pressure: 5-6 bar Micro Pellets (Ø1,7 mm) Round nozzle inside machine Wide angle nozzle on surfaces Feasibility study: Dry Ice was preferred because: • The process is dry • Short down time • Dry ice could be produced on-site using Aquila Triventek PE80 + RE80 equipment, generator and a mobile CO2 tank • Use to be manually cleaned. 1 machine per hour. With Dry Ice cleaning is 15 min. Pay attention to sensors and plastic clips Do not blast directly into bearings Aquila Triventek A/S · Industrivej 9 · DK-5580 Nørre Aaby · Tel. +45 70 22 12 92 · [email protected] · www.aquila-triventek.com