1. Catalogs
  2. Applied Measurements
  3. Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Pi600 Series

Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Pi600 Series

Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Pi600 Series

Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Pi600 Series

Product catalog summary
Overview
The Pi600 series pressure sensors are designed for measuring liquid and gas pressures across various industrial and specialized applications such as hydraulics, pneumatics, agriculture, marine, sewage, gas, medical, chemical, food processing, barometers, and dataloggers. They offer pressure ranges from 0-25mbar to 0-700bar in both gauge and absolute models, with a variety of electrical output signals.

Construction and Features
These sensors are constructed from stainless steel with a ceramic diaphragm for pressures below 1bar, ensuring ruggedness and compact design. They are sealed to IP65 or IP66/68 standards, providing excellent chemical and abrasion resistance. The sensors can be integrated with a range of instrumentation for a complete system solution.

Specifications
  • Pressure Ranges: 0.025 to 700 bar
  • Rated Output: Various options including 2mV/V, 10mV/V, 0-5V, 0.5-4.5V, 4-20mA
  • Accuracy: Combined error due to non-linearity, hysteresis, and repeatability
  • Temperature Range: Compensated from -20 to +135°C
  • Environmental Protection: IP65 or IP66/68
  • Excitation Voltage: 10-32Vdc
  • Response Time: <1 millisecond
  • Safe Overpressure: 150% of rated pressure
  • Stability: <0.1% over 12 months


Options and Customization
The Pi600 series offers options for interim pressure ranges, different material constructions for compatibility, special output scaling, and improved accuracy options. They can be supplied with any instrumentation and calibrated as a complete system with a traceable certificate.

Contact Information
Applied Measurements Limited, 3 Mercury House, Calleva Park, Aldermaston, Berkshire, RG7 8PN, UK. Tel: (+44) 0118 981 7339, Fax: (+44) 0118 981 9121, Email: [email protected], Website: www.appmeas.co.uk
See more

Catalog excerpts

Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Pi600 Series-1

Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Gauge or Absolute Versions Sealed to IP65 (Plug & Socket) or Excellent Chemical Rugged Construction Wide Choice of Electrical Outputs Options Available Interim Pressure Ranges (Consult Factory) Manufactured from Different Materials for Different Application Special Output Scaling (Consult Factory) 6-Pin Bayonet connector or DIN43650 Plug & Socket (Hirschmann) Improved accuracy (NL&H) - <±0.l0%/span BFSL Improved accuracy (TZS) - < ±0.02% or < ±0.01 % /span/°C (Thermal Zero Shift) Supplied With Any Instrumentation and Calibrated as a Complete System with Traceable Certificate 3 16 Stainless Steel case or High Grade Stainless Steel Case The Pi600 series of pressure sensors has been engineered for the measurement of liquid and gas pressures in a diverse range of industrial and specialised applications, including:- Hydraulics, Pneumatics, Agriculture, Marine, Sewage, Gas, Medical, Chemical, Food Processing, Barometers, Dataloggers etc. Pressure ranges between 0-25mbar and 0-700bar are available in gauge or absolute* models with a wide choice of electrical output signals to meet operational requirements. Constructed from stainless steel with a ceramic diaphragm (316 Stainless Steel diaphragm below I bar), the Pi600 series of transducers are extremely rugged yet of compact design. The Pi600 series can be further complimented by any of our range of instrumentation to offer a complete system, supplied and calibrated from a single source. * Minimum absolute range 0-500mbar. Transducer Specialists. APPLIED MEASUREMENTS LIMITED_ 3 MERCURY HOUSE - CALLEVA PARK - ALDERMASTON - BERKSHIRE - RG7 8PN - UK

 Open the catalog to page 1
Low Range Stainless Steel Amplified & Non-Amplified Output PRESSURE SENSOR Pi600 Series-2

mV/V output is not available below I bar 1 I OVdc nominal excitation. Please advise on order if transducer is to be used with 28-32Vdc excitation ' Combined Error (Accuracy) is the combined error caused by the effects of Non-Linearity, Hysteresis and Repeatability ' IP68 rated to I metre depth maximum ' Minimum Absolute range 0-500mbar Four Core Cable. APPLIED MEASUREMENTS LIMITED Continuous product development may result in minor changes to published specifications.

 Open the catalog to page 2

All Applied Measurements catalogs and technical brochures

  1. T24-HR

    2  Pages

  2. T24-HA

    2  Pages

  3. T24-HS

    2  Pages

  4. T24-BSi

    2  Pages

  5. T24-BSue

    2  Pages

  6. T24-BSu

    2  Pages

  7. T24-ACM

    2  Pages

  8. T24-RA

    2  Pages

  9. T24-TA

    2  Pages

  10. T24-PA

    2  Pages

  11. T24-IA

    2  Pages

  12. T24-SAf

    2  Pages

  13. T24-SA

    2  Pages

  14. SY021

    2  Pages

  15. TR200

    2  Pages

  16. TR150

    2  Pages

  17. DSJ4

    2  Pages

  18. DSJ1

    2  Pages

  19. DCell

    4  Pages

  20. CCG series

    2  Pages

  21. AMLJBNA

    1  Page

  22. DSC-USB

    3  Pages

  23. DSC

    4  Pages

  24. ICA

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.