APM TECHNOLOGIES PROFESSIONAL INNOVATIVE BRANDING SERVICE Smart MTL Series 3-Phase Inverter User Manual
Open the catalog to page 1Smart MTL Series 3-Phase Inverter User Manual
Open the catalog to page 3Forword Dear customer, Thank you for using this Smart MTL Series 3-Phase Photovoltaic Grid-Connected Inverter a product developed & manufactured by APM Technologies. We sincerely hope that this product will meet your needs. The sections outlined in this user manual are suitable for PV17KM3TL / PV20KM3TL / PV23KM3TL solar inverters. Smart stands for flexible and smart, and MTL indicates the appliance is without a transformer (transformerless) and supports for multi-channels of MPPT. Please read the user manual carefully before using the Smart MTL Series 3-Phase Photovoltaic Grid-Connected...
Open the catalog to page 6Smart MTL Series 3-Phase Inverter User Manual--Safety Instructions Safety Instructions ! Danger! Improper operation may cause serious body injury or appliance damage. Warning! Improper operation may cause serious body injury or appliance damage. Caution! Improper operation may cause medium body injury or appliance damage. Description Please read this user manual carefully before use this appliance. Symbols on the Type Label 2 minutes Be careful of electric shock and do not touch the appliance in 2 minutes after power off. Beware of hot surface. The inverter will become hot during operation....
Open the catalog to page 7Smart MTL Series 3-Phase Inverter User Manual--About this Manual About this Manual 1.1 Scope This manual provides the reader with detailed product information as well as installation, operation and maintenance instructions. This manual also provides our company contact information so that you can tell us your suggestions and comments about the performance of our products in order that we can continue to improve our product quality and our level of service. 1-1 1.2 Targeted Audience This manual is intended for product users and technical personnel that are involved with installing, operating...
Open the catalog to page 8Smart MTL Series 3-Phase Inverter User Manual--Unpacking 2.1 Packing List Descriptions Solar Inverter Mounting Bracket Expansion Bolt For fixing the mounting bracket User Manual English Version Warranty Card English Version Packing List English Version Qualification Card English Version Installation Quick Guide English Version Warranty Card APM technologies (Dongguan) Co.,Ltd
Open the catalog to page 9Smart MTL Series 3-Phase Inverter User Manual--Unpacking 2.2 Checking for Shipping Damage All APM Technologies Company products have undergone stringent testing before delivery, but inevitably damage can happen during transportation. Once you receive the product, please immediately check if there is any packaging damage that may indicate damage to the product. If you find damage related to product delivery, please immediately notify the transport company. Make sure to take photos documenting the damage to the product, and send them to us so that we can provide you with the best service....
Open the catalog to page 10Smart MTL Series 3-Phase Inverter User Manual--Products Introduction Products Introduction Danger! Smart MTL Series 3-Phase Photovoltaic Inverter is not applicable to the photovoltaic array with the negative (-) and positive (+) poles which are requiring a ground connection. Grid-connected photovoltaic power generation system consists of the photovoltaic array, solar inverter, metering devices and grid. The photovoltaic array is made up of PV modules which convert the solar energy into DC power. As the vital part of the system, the solar inverter converts the DC power into AC power and...
Open the catalog to page 11Smart MTL Series 3-Phase Inverter User Manual--Productions Intruduction DC2 IGBT Three-Level Inverter Circuit PROFESSIONAL INNOVATIVE
Open the catalog to page 12Smart MTL Series 3-Phase Inverter User Manual--Products Intruduction Operating Voltage Range MPPT Voltage (full load) Rated Input Range Input String Channels MPPT Path Output (AC) Rated Power (230V, 50Hz) Rated Output Voltage Rated Output Frequency Power Factors
Open the catalog to page 13Smart MTL Series 3-Phase Inverter User Manual--Productions Introduction European Efficiency Nighttime Loss Protection Parameters Input DC Switch Anti-islanding Protection Output Overcurrent Protection Input Reverse Connection Protection Insulation Resistance Detection RS485 (standard), Etherent (optional), WiFi (optional) Ambient Parameter Operating Temperture Operation Humidity Protection Level Noise Index Components Weight Dimensions (WxHxD) PROFESSIONAL INNOVATIVE
Open the catalog to page 14Smart MTL Series 3-Phase Inverter User Manual--Installation Installation, operation and maintenance of the Smart MTL Series 3-Phase Photovoltaic Inverter must strictly adhere to the regulations and instructions hereafter: Please apply for the approval of local power supply authority before using the solar inverter to generate power, and all the related operation must be carried out by a qualified person. All the electrical installations must be in accordance with local electrical standards. Because of the solar inverter involves high voltage in its operation, external power supply must be...
Open the catalog to page 15Smart MTL Series 3-Phase Inverter User Manual--Installation 4.3 Ambient Conditions 1. Please install the solar inverter in a clean and well-ventilated environment or at the outdoor without a direct exposure to sun. 2. Keep the ambient temperature within the range of -25℃ to 60℃ as an over temperature may affect the electricity production. 3. It is advised not to install the inverter in living quarters, since the inverter may produce some operating noise. 4. Keep the solar inverter in a place out or reach of children to avoid scalding or electric shock. 5. Provide at least a minimum space...
Open the catalog to page 16Smart MTL Series 3-Phase Inverter User Manual-lnstallationi • Please install the solar inverter in a place which is stable and solid enough to bear the dead weight of the inverter for long term. • Ensure there is no interference by other electrical equipment around the solar inverter. 1. Install the solar inverter in a vertical position, and ensure the con- ■J /// nection ports are located underneath or face down. 2. It is prohibited to install the inverter obliquely towards the front. 3. It is prohibited to install the inverter horizontally. 4. It is prohibited to install the inverter...
Open the catalog to page 17All APM Technologies (Dongguan) Co. catalogs and technical brochures
-
Programmable Power Supply
34 Pages
-
Three Phase AC Source System
6 Pages
-
DC Source System
33 Pages
-
USER MANUAL of on grid inverter
48 Pages
-
3KW OFF GRID INVERTER
1 Pages
-
Solar inverters
1 Pages
-
Tree Phase On-grid Inverter
1 Pages