Specifications:
The document describes the APC-2000ALW/L smart level probe, which is designed for measuring liquid levels in various environments such as tanks, deep wells, and piezometers. It is suitable for liquids containing contaminants or suspensions and can measure hot liquids up to 120°C. The probe features a 4...20 mA output signal with HART protocol, programmable zero shift, range, and damping ratio, and has an accuracy of 0.16%. It is equipped with a local display and has intrinsic safety certification (ATEX, IECEx).
Technical Data:
Metrological parameters include an accuracy of ±0.16%, long-term stability of 0.16% over 2 years, and a thermal error of < ±0.1% (FSO) per 10°C. The thermal compensation range is -25...100°C, with a special version available for -40...80°C. The power supply requirement is 10...55 VDC, and the output signal is 4...20 mA with HART protocol. The operating temperature range is -40...85°C, with medium temperature ranges varying based on cable type.
Configuration and Communication:
The probe allows configuration of pressure units, start and end-points of the set range, damping time constant, and inverted characteristic. Communication is facilitated through the Hart protocol using devices like the KAP-03 communicator or Raport 2 software.
Measuring Range:
The nominal measuring ranges are 0...20 m H2O, 0...10 m H2O, and 0...2.5 m H2O, with corresponding minimum set ranges and overpressure limits.
Model Code and Accessories:
The document lists various model codes and descriptions, including sensor types and cable options. Accessories such as mounting brackets and flange type connections are also mentioned.
See more

Catalog excerpts

Smart level probe type APC-2000ALW/L-1

Smart level probe type APC-2000ALW/L ü Programmable zero shift, range and damping ratio ü output signal + HART protocol 4...20 mA ü 0,16% Accuracy ü Local display ü safety certificate (ATEX, IECEx) Intrinsic II 1/2G Ex ia IIB T4/T5 Ga/Gb II 1D Ex ia IIIC T105 C Da Electronic part IP 66 / IP67 working temp.: -40...+80°Ñ 4 holes Æ 7 (spacing of holes 38´ 38 mm) Sensor type IP68 working temp.: -40...+120°Ñ Æ 60 Submersible sensor type SGE-25S Submersible sensor type SGE-25 Thread or flange mounted sensor. (Type of flange or thread has to

 Open the catalog to page 1
Smart level probe type APC-2000ALW/L-2

^plisenS APC-2000ALW/L function: ef 4.20 mA output signal + HART protocol, et Possibilities of the adjusting both zero point and of the start and end of the measuring range, characteristic ete.with the display panel keys, Ef Configurable display 5 digits with illumination (working temperature range -40.+85°C) Electrical diagrams Application The APC-2000ALW/L level probe is applicable to measure liquid levels in tanks, deep wells or piezometers. The APC-2000ALW/L probe is applicable to measure levels of liquids containing contaminants or suspensions. A typical use for this probe is the measurement...

 Open the catalog to page 2