2019-2020 PRODUCT CATALOGUE
176Pages

{{requestButtons}}

Catalog excerpts

2019-2020 PRODUCT CATALOGUE - 1

PRODUCTS CATALOGUE PRESSURE \ FLOW LEVEL TEMPERATURE

Open the catalog to page 1
2019-2020 PRODUCT CATALOGUE - 2

Chapters Devices for measurement of pressure or level in open tanks Devices for measurement of differential pressure or level in pressure tanks Diaphragm seals Valves and fitting accessories Hydrostatic level probes, hydrostatic density transmitter Digital indicators Power supplies, isolators, signal converters, overvoltage protection Flow measurement Temperature transmitters Temperature sensors Electropneumatic positioner Hart communication tools

Open the catalog to page 2
2019-2020 PRODUCT CATALOGUE - 4

SMART PRESSURE TRANSMITTER APC-2000ALW ü mA output signal + HART protocol 4…20 (special version: 0…20 mA or 0…5 mA output signal + HART protocol) ü with backlight Display ü Programmable range, zero shift, characteristic and damping ratio with local panel keys ü SIL 2 certificate rs ü safety certificate (ATEX, IECEx) Intrinsic 5 yea up to rranty ü Explosion proof certificate (ATEX, IECEx) wa ü certificate – DNV, BV Marine ü PED Conformity (97/23/EC) ü Accuracy 0,075% (0,05% on request) ü Gold plated diaphragm (Au) ü MID (Measuring Instruments Directive) – certificate acc. to 2004/22/WE...

Open the catalog to page 4
2019-2020 PRODUCT CATALOGUE - 5

-flPLISENV — Application and construction Smart pressure transmitters are applicable to the measurement of the pressure, underpressure and absolute pressure of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor separated from the medium by a diaphragm and by specially selected type of manometric liquid. The casing is made of aluminium alloy cast or 316SS stainles steel, degree of protection IP66/IP67. The design of the casing enables the use of a local display, rotation of the display, rotation of the casing by 0-340° relative to the sensor, and a...

Open the catalog to page 5
2019-2020 PRODUCT CATALOGUE - 6

Accuracy depending on the set range p0 - error for range 30...100% FSO p1 - error for range 10% FSO P1 =2* p0 Numerical error values are given in the technical data under metrological parameters Wetted parts and diaphragms: 316Lss, Hastelloy C 276, Au Material of window: polycarbonate glass, hardened glass Operating conditions Operating temperature range (ambient temp.) -40...85°C Medium temperature range -40...120°C over 120°C - measurement with use an impulse line or diaphragm seals up to 100°C - PED version CAUTION: the medium must not be allowed to freeze in the...

Open the catalog to page 6
2019-2020 PRODUCT CATALOGUE - 7

Ordering procedure Model APC-2000 Casing, output signal Versions, certificates* Description Smart pressure transmitter Aluminum housing, IP66, with display, output 4-20mA + Hart Stainless steel housing, IP66, with display, output 4-20mA + Hart II 1/2G Ex ia IIC T4/T5 Ga/Gb IECEx Ex ia IIC T4/T5 Ga/Gb II 1/2G Ex ia IIC T4/T5 Ga/Gb II 1D Ex ia IIIC T105°C Da I M1 Ex ia I Ma (version with SS housing) Ex ia IIC T4/T5 Ga/Gb IECEx Ex ia IIIC T105°C Da Ex ia I Ma (version with SS housing) II 1/2G Ex ia/db IIC T6/T5 Ga/Gb II 1/2D Ex ia/tb IIIC T85°C/T100°C Da/Db I M2 Exd ia I Mb (version with SS...

Open the catalog to page 7
2019-2020 PRODUCT CATALOGUE - 8

flPLISENS Code Example: Pressure transmitter, output 4...20mA + HART, version Exia, nominal measuring range 0...7bar, calibrated range 0...6bar, process connection %”NPT male, electrical connection %”NPTF. APC-2000ALW/Exia/0..7bar/0..6bar/PD/1/2”NPTM/US

Open the catalog to page 8
2019-2020 PRODUCT CATALOGUE - 9

SMART PRESSURE TRANSMITTER APCE-2000 üm A output signal + HART protocol 4…20 üIntrinsic safety ATEX ü Gold plated diaphragm (Au) ü Accuracy 0.1% Application The APCE-2000 pressure transmitter is applicable to the measurement of the pressure, underpressure or absolute pressure of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor separated from the medium by a diaphragm and by specially selected type of manometric liquid. Economical version: Version designed to work in hard conditions: - housing 304ss - protection IP65 - electrical connection DIN EN...

Open the catalog to page 9
2019-2020 PRODUCT CATALOGUE - 10

Installation The transmitter is not heavy, so it can be installed directly on the installation without additional mounting bracket. When the pressure of steam or other hot media is measured, a siphon or impulse line should be used. The needle valve placed upstream the transmitter simplifies installation process and enables the zero point adjustment or the transmitter replacement. When the special process connections are required for the measurement of levels and pressures (e.g. at food and chemical industries), the transmitter is provided with an Aplisens diaphragm seal. Installing...

Open the catalog to page 10
2019-2020 PRODUCT CATALOGUE - 11

flPLISENSOrdering procedure Model Example : Pressure transmitter , output 4..20mA + HART, version Exia, nominal measuring range 0..7bar, calibrated range 0..6bar, p rocess connection G1/2”, electrical connection DIN EN 175301-803 connector. APCE-2000PD/Exia/0..7bar/0..6bar/G1/2”

Open the catalog to page 11
2019-2020 PRODUCT CATALOGUE - 12

SMART PRESSURE TRANSMITTER PCE-28.SMART ü mA output signal + HART protocol 4…20 ü safety certificate (ATEX, IECEx) Intrinsic ü Accuracy 0.1% ü certificate – DNV, BV Marine APLISENS S.A. Produkcja Prze Aparatury Pom APLISENS S.A. Produkcja Prze Aparatury Pom Numer fabrycz Zakres pomiar Sygna³ wyjœcio Zasilanie PRZETWORNI Numer fabrycz Zakres pomiar Sygna³ wyjœcio Zasilanie 1/2’’NPT male + internal thread G1/4’’ 1/4”NPT F type internal thread 1/4-18NPT G1" with flush diaphragm G1" with flush diaphragm M30×2 with flush diaphragm Version with direct

Open the catalog to page 12
2019-2020 PRODUCT CATALOGUE - 13

The communication standard for data interchange with the transmitter is the Hart protocol. Communication with the transmitter is carried out with: - a KAP-03, KAP-03Ex communicator - some other Hart type communicators^*) - a PC using an HARt/USB converter and Raport 2 configuration software. (*) .eddl files available on www.aplisens.com. -^plisenS* — Application PCE-28.SMART pressure transmitter is applicable to the measurement of the pressure, underpressure and absolute pressure of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor separated from the...

Open the catalog to page 13

All APLISENS S.A. catalogs and technical brochures

Archived catalogs

  1. APC-2000ALW

    5 Pages