DAT CONTROLER® PLUS
3Pages

{{requestButtons}}

Catalog excerpts

DAT CONTROLER® PLUS - 1

DATA SHEET >INTERCEPTION SYSTEMS AND ACCESSORIES > ESE LIGHTNING AIR TERMINALS > DAT CONTROLER® PLUS > GENERAL DESCRIPTION DAT CONTROLER® PLUS is an Early Streamer Emission (ESE) air terminal based on the electrical characteristics of lightning formation. The air terminal triggers the continuous upward leader before any other object within its radius of protection. This feature is referred to in the regulations as the advance timeof an ESE air terminal (ΔT). The earlier the upward leader is triggered, the larger is the distance where the downward leader is intercepted, thus protecting a greater area against lightning (standards limit it to ΔT≤60 μs). DAT CONTROLER® PLUS terminals offer the highest performance guarantees: 1 REGULATION REQUIREMENTS* In accordance with the standard NF C 17-102:2011 “Early Streamer Emission air terminals” Salt mist test Humid sulphurous atmosphere test Withstand current test: 100 kA (10/350 μs) Advance time ΔT test BEYOND THE STANDARDS: ADDITIONAL FEATURES AENOR MARK In accordance with the AENOR RP 058 specific regulation for ESE air terminals Monitoring samples taken by AENOR technicians Tests in official and independent laboratories Certified withstand current 100 kA, 20 impulses (10/350 μs) Performance under rain (insulation above 95%) Direct application of 20 impulses of current (10/350 μs) with a peak current higher than 100 kA and specific energy greater than 2.5 MJ/Ω Test according to IEC-EN 60060-1:2012 The patented design of the DAT CONTROLER® PLUS prevents rain creating contact between the metal housing at atmospheric electric potential (in blue) and the grounded metal axis (in red) The source feeding the triggering device of an ESE air terminal is the high difference in the potential between its insulated metal frames during a thunderstorm. It is necessary to guarantee such a difference in potential in the event of rain. Checking the state of the air terminal In situ (DAT CONTROLER® PLUS) Remote checking (DAT CONTROLER® PLUS + AT-REMOTE TESTER) *The last edition of the standard UNE 21186, NF C 17-102 and NP 4426 requires, consecutively and on the same sample, the following tests: 1. Environmental tests, in atmospheres with a high salt and sulphur concentration, in order to ensure the correct operation of the air terminal in highly corrosive atmospheres. 2. Current test, applying 3 impulses of 100 kA with a 10/350 μs wave to the air terminal in order to ensure it works after repeated lightning strikes. 3. Advance time test for calculating the ΔT factor which will determine its protection radius. Aplicaciones Tecnológicas S.A. - Parque Tecnológico de Valencia - Nicolás Copérnico, 4 - 46980 Paterna (Valencia), Spain T +34 961 318 250 - F +34 961 318 206 - atsa

Open the catalog to page 1
DAT CONTROLER® PLUS - 2

>INTERCEPTION SYSTEMS AND ACCESSORIES > ESE LIGHTNING AIR TERMINALS> TECHNICAL CHARACTERISTICS Material: The installation of DAT CONTROLER® PLUS air terminals shall follow UNE 21186:2011, NF C 17-102:2011 and NP 4426:2013. “Lightning protection: ESE lightning air terminals”. > DAT CONTROLER® PLUS ADVANCE TIMES (AT) DAT CONTROLER® PLUS air terminals have passed all the tests according to the standards For safety and ease of calculation, the results have been rounded down thus certifying the following advance times (AT) in microseconds: h (m): Height of the air terminal over the element to be...

Open the catalog to page 2
DAT CONTROLER® PLUS - 3

DATA SHEET >INTERCEPTION SYSTEMS AND ACCESSORIES > ESE LIGHTNING AIR TERMINALS > DAT CONTROLER® PLUS CERTIFICATIONS RADIUS PROTECTION CERTIFICATE AND REGULATION COMPLIANCE Radius protection certificate for each model and level calculated according to standards UNE 21186:2011, NF C 17-102:2011 and NP 4426:2013. AENOR PRODUCT CERTIFICATION NO. 058/000005 • Certified resistance to extreme environmental conditions (salt mist test and humid sulphurous atmosphere treatment). • Certified withstand current: 100 kA (10/350 μs). • Certified advance time ΔT (Annex C, NF C 17-102:2011). WITHSTAND...

Open the catalog to page 3

All Aplicaciones Tecnológicas catalogs and technical brochures

  1. EARTHING

    24 Pages

  2. IGA TEST T

    1 Pages

  3. ATFONO RJ45

    2 Pages

  4. ATSUB-P

    5 Pages

  5. ATSUB-D M

    2 Pages

  6. ATSUB-R

    5 Pages

  7. ROD BRACKETS

    1 Pages

  8. FLAT SADDLE

    1 Pages

  9. AIR ROD BASE

    1 Pages

  10. RIDGE SADDLE

    1 Pages

  11. ATSHOCK

    2 Pages

  12. full catalogue

    438 Pages

Archived catalogs