ATSUB-D M

ATSUB-D M

ATSUB-D M

Product catalog summary
Product Overview:
The ATSUB-D M (AT-8216) is a surge protection device designed for medium protection of power supply lines, particularly suitable for domestic use. It is certified as a type 2 and 3 protector according to EN 61643-11 and REBT standards, and is compatible with categories I, II, III, and IV equipment.

Installation Guidelines:
The device should be installed in parallel with the low voltage line, connecting to the phases to be protected, as well as to neutral and/or ground. It is crucial to ensure no power is running through the line during installation. For optimal performance, it should be separated from coarse and/or tight protectors by at least 10 meters of cable or an ATLINK decoupling inductor.

Technical Specifications:
  • Nominal Voltage: 230 VAC
  • Maximum Continuous Operating Voltage: 400 VAC
  • Nominal Discharge Current: 5 kA
  • Maximum Discharge Current: 15 kA
  • Protection Level at Nominal Discharge Current: 1500 V
  • Response Time: < 25 ns
  • Operating Temperature: -40 ºC to +70 ºC
  • Dimensions: 36 x 90 x 80 mm
  • Enclosure Material: Polyamide, IP20 protection

Key Features:
  • Utilizes zinc oxide varistors and gas discharge tubes for high current endurance.
  • Compact design with no power supply interruption upon activation.
  • Includes thermodynamic control, mechanical warning, and remote alarm features.
  • Self-extinguishing enclosure compliant with V-0 Type according to UNE-EN 60707 (UL94).

Compliance and Testing:
The ATSUB-D M has been tested in independent laboratories and complies with UNE-EN 61643-11, UL 1449, and other relevant standards such as UNE 21186, NF C 17-102, and IEC 62305.

Installation Requirements:
Proper earthing is mandatory, with resistance lower than 10 Ω. Failure to adhere to installation guidelines may compromise device protection.
See more

Catalog excerpts

ATSUB-D M-1

DATA SHEET > PROTECTION OF POWER SUPPLY LINES > ATSUB SERIES > ATSUB-D M Compact single-phase protection for domestic use > AT-8216 ATSUB-D M: peak current 15 kA. Un 230V Effective protection against transient overvoltages for single-line electrical supply lines with TT type neutral, using metal oxide varistors and gas discharge tubes. Medium protection according to the cascade protection recommended in the Spanish Low Voltage Regulations (REBT ITC23). Especially made to be installed in houses according to ITC-25 from REBT. Tested and certified as a type 2 and 3 protector according to the standard EN 61643-11 and GUÍA-BT-23 from the REBT. Suitable for categories I, II, III and IV equipment according to the REBT. > Can be coordinated with protectors from the ATSHOCK, ATSHIELD and ATCOVER series. > Made up of zinc oxide varistors and gas discharge tubes able to withstand very high currents. > Short response time. > Do not produce deflagration. > Compact protection. > Their activation causes no interruption in power supply. > Thermodynamic control device, mechanical warning and remote alarm. When the warning light is yellow, the protector is in good condition. If not, replace. > INSTALLATION They are installed in parallel with the low voltage line, with connections to the phases that are to be protected, as well as to neutral and/or ground. Installation should be carried out without power running through the line. When ATSUB protectors are installed as medium protection, they must be separated from the coarse and/or tight protectors by at least 10 metres of cable or, if this is not possible, by an ATLINK decoupling inductor, in order to achieve correct coordination between them. They are especially recommended for the main switchboard of houses according to article 16.3 from the REBT. ATSUB series protectors have been tested in official, independent laboratories, obtaining their characteristics according to relevant standards (listed in the table). Connection to earth is a must. Earthing in the whole installation must be bonded either directly or by a spark gap and resistance should be lower than 10 Ω. If the indications on this datasheet are not fulfilled during use or installation of the protectors, the protection provided by this device could be compromised. Aplicaciones Tecnológicas S.A. - Parque Tecnológico de Valencia - Nicolás Copérnico, 4 - 46980 Paterna (Valencia), Spain T +34 961 318 250 - F +34 961 318 206 - [email protected] - www.at3w.

 Open the catalog to page 1
ATSUB-D M-2

> PROTECTION OF POWER SUPPLY LINES > ATSUB SERIES> TECHNICAL DATASHEET Reference: (1) Required in cases where there is higher nominal current installed upstream from the protector > DIMENSIONS (MM) Aplicaciones Tecnologicas S.A. - Parque Tecnologico de Valencia - Nicolas Copernico, 4 - 46980 Paterna (Valencia), Spain T +34 961 318 250 - F +34 961 318 206 - [email protected] - www.at3w.com

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.