Basco Engineered Shell & Tube Heat Exchangers
1 / 12Pages

Catalog excerpts

Basco Engineered Shell & Tube Heat Exchangers - 1

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:19.00pt "Microsoft Sans Serif", sans-serif; } .font1 { font:34.00pt "Microsoft Sans Serif", sans-serif; } .font2 { font:13.00pt "Times New Roman", serif; } .font3 { font:106.00pt "Times New Roman", serif; } BSCO BASCO ENGINEERED SHELL & TUBE HEAT EXCHANGERS 1 Heat Transfer ...world leaders in heat transfer technology

Open the catalog to page 1
Basco Engineered Shell & Tube Heat Exchangers - 2

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:15.00pt "Arial Black", sans-serif; } .font1 { font:8.00pt "Microsoft Sans Serif", sans-serif; } .font2 { font:9.00pt "Microsoft Sans Serif", sans-serif; } .font3 { font:11.00pt "Microsoft Sans Serif", sans-serif; } .font4 { font:26.00pt "Palatino Linotype", serif; } .font5 { font:32.00pt "Palatino Linotype", serif; } .font6 { font:15.00pt "Times New Roman", serif; } .font7 { font:19.00pt "Times New Roman", serif; } API Heat Transfer is your one source for custom engineered shell &...

Open the catalog to page 2
Basco Engineered Shell & Tube Heat Exchangers - 3

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:12.00pt "Arial", sans-serif; } .font3 { font:17.00pt "Arial", sans-serif; } .font4 { font:13.00pt "Franklin Gothic Medium", sans-serif; } .font5 { font:18.00pt "Times New Roman", serif; } Manufacturing API Basco is located in Buffalo, NY within a few miles of major highway, air and rail transportation. Our 132,000 sq. ft. manufacturing space is ISO 9001 certified and houses extensive fabrication...

Open the catalog to page 3
Basco Engineered Shell & Tube Heat Exchangers - 4

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:12.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Times New Roman", serif; } Engineering Capabilities In-House Resources Degreed staff engineers Օ Applications expertise Mechanical design know-how Օ Product development capabilities Code Capabilities ASME Section VIII Օ PED TUV Օ Chinese CML ASME Section I Օ TEMA C, B & R Canadian Registration Օ Australian AS-1210 Polish UDT Օ Korean...

Open the catalog to page 4
Basco Engineered Shell & Tube Heat Exchangers - 5

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:12.00pt "Arial", sans-serif; } .font3 { font:18.00pt "Arial", sans-serif; } Manufacturing Capabilities Manufacturing Skills Torque control rolling Օ Seal and strength welding Polishing, Sanitary 3A Օ TIG, MIG, GMAW, GTAW, SAW and SMAW welding techniques TEMA tight drilling tolerances Quality Assurance Օ X-ray Magnetic particle Օ Heat treatment ISO 9001 Օ Resident ASME code inspector Helium...

Open the catalog to page 5
Basco Engineered Shell & Tube Heat Exchangers - 6

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:12.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:23.00pt "Arial", sans-serif; } Basco People & Solutions API Basco Shop Bundle Assembly Area API Basco Shop Type OP Assembly Area Team Basa Evaporator with Disengagement Drum Gland Condenser Package Stacked TEMA AEW's with Transfer Values TEMA BEU Exchanger for Wastewater Treatment TYPE ES Intercoolers on a Compressor Package High Pressure TEMA...

Open the catalog to page 6
Basco Engineered Shell & Tube Heat Exchangers - 7

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:18.00pt "Arial", sans-serif; } TEMA Shell & Tube Nomenclature API Basco is a proud member of TEMA - Tubular Exchanger Manufacturer's Association. TEMA members set the standards by which virtually all custom shell & tube heat exchangers are specified and built. Basco has been a member since the 1950's, and consequently we have a complete and comprehensive understanding of the engineering, manufacturing and testing requirements to meet this...

Open the catalog to page 7
Basco Engineered Shell & Tube Heat Exchangers - 8

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:19.00pt "Franklin Gothic Medium", sans-serif; } TEMA Shell & Tube Spcifications TEMA BET Description: Pull through tube bundle □ studded internai floating head to tubesheet joint □ multi-pass tubeside or single pass with Slip Tube design □ channel or bonnet tubeside connection □ pressure range - 75 psi to 300 psi. Applications: Liquid heaters with low...

Open the catalog to page 8
Basco Engineered Shell & Tube Heat Exchangers - 9

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:15.00pt "Arial", sans-serif; } .font3 { font:18.00pt "Arial", sans-serif; } .font4 { font:19.00pt "Franklin Gothic Medium", sans-serif; } TEMA Shell & Tube Spcifications TEMA BEP Description: Removable tube bundle, outside packed floating tubesheet design. Tubesheet assembly may be of fabricated or forged steel to satisfy design pressure requirements □ tubeside fluid is fully gasketed; shellside...

Open the catalog to page 9
Basco Engineered Shell & Tube Heat Exchangers - 10

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:17.00pt "Arial Black", sans-serif; } TEMA Shell & Tube Spcifications TEMA BEU Description: U-tube design with pull through, removable or non-removable tube bundle □ furnished in multi-pass design only □ pressure range - 75 psi to 3000 psi tubeside and 75 psi to 1500 psi shellside. Applications: Chemical processes □ tank suction heater □ liquid heaters...

Open the catalog to page 10

All API Schmidt-Bretten catalogs and technical brochures

  1. OCA Series

    6 Pages

  2. SIGMASTAR

    2 Pages

  3. BOL Series

    8 Pages

  4. AOC Series

    4 Pages

  5. AOL Series

    4 Pages

  6. BOL Series

    6 Pages

  7. SIGMASHELL

    1 Pages

  8. Basco Type 500

    12 Pages

Archived catalogs

  1. EKT Series

    2 Pages

  2. BPCH Series

    2 Pages

  3. BPS Series

    4 Pages

  4. BP Series

    20 Pages

  5. EK Series

    8 Pages

  6. EC Series

    6 Pages

  7. CA Series

    4 Pages

  8. UC Series

    5 Pages

  9. DH Series

    4 Pages

  10. MA Series

    4 Pages

  11. OCA Series

    28 Pages