Catalog excerpts
EQUIPMENT CATALOG FLOW PRESSURE Website: www.apexinst.com Contact: info@apexinst.com Apex Instruments, Inc. 204 Technology Park Lane Fuquay-Varina, N.C. 27526, U.S.A. Last Edited 12.12.21
Open the catalog to page 1Your solution for source sampling equipment. Welcome to Apex Instruments! Dear Valued Customer, Over the last 30 years it’s been our mission to bring high-quality equipment to the source testing industry at competitive prices. This commitment has driven us to continually improve our products and develop solutions for our customers to compete in an everchanging regulatory landscape. I’d like to take this opportunity to thank all our customers for their support and let you know that the entire Apex Instruments team looks forward to our continued partnership by providing innovative products...
Open the catalog to page 2Ordering Options and Information Order by phone: Call our friendly and knowleadgable sales ISOKINETIC SAMPLING EQUIPMENT staff anytime to place an order at 800-882-3214 or 919-557-7300 Monday-Friday, 8:00 a.m. to 5:00 p.m. (Eastern Time). Shop on-line: Submit a quote request online or send us an email and we will get back to you as soon as possible. www.apexinst.com. Order by fax: 919-557-7110. Payment Options: Apex Instruments, Inc. accepts Master- FLOW MEASUREMENT EQUIPMENT MERCURY SAMPLING SYSTEMS AND EQUIPMENT Card, VISA, American Express and wire transfers. Installment and credit plans...
Open the catalog to page 3ISOKINETIC SOURCE SAMPLING EQUIPMENT ISOKINETIC SOURCE SAMPLING EQUIPMENT Versatile System for Multiple Methods Apex Instruments Inc. offers an extensive line of equipment and supplies for sampling stationary source emissions for pollutants in accordance with US EPA Reference Methods. The majority of the methods are generally classified as either isokinetic or gaseous sampling Methods. This section includes the Apex Instrument line of Isokinetic equipment and accessories. Isokinetic sampling requires the sample to be withdrawn from the gas stream at the same rate it is moving through the...
Open the catalog to page 4ISOKINETIC SOURCE SAMPLING EQUIPMENT Method Index Isokinetic Systems by Method Method 5 Conditional Test Method 13 Method ASTM D6784-02 (Ontario Hydro) Flow and Temperature Systems by Method Method 1 Mercury Systems by Method Method 30B Gas Analysis Products by Methods Method 3 Email: info@apexinst.com
Open the catalog to page 5ISOKINETIC SOURCE SAMPLING EQUIPMENT Method Specific Sampling Kits Method 4 (page 45) mpling Schematic Moisture Content - Method 4 Determination of the Moisture Content of Stack Gas Summary: Stack gas is extracted at constant rate (less than 21LPM) and a minimum volume of 600 liters. Water vapor is condensed from the sample stream, and measured volumetrically or gravimetrically. The Method 4 kit includes a probe, glassware, u-cord and parts to be able to build both the rigid and flexible arrangements. Method 5 (page 46-48) Particulate Emissions from Stationary Sources - The professional...
Open the catalog to page 6ISOKINETIC SOURCE SAMPLING EQUIPMENT Method 23 (page 53) Dioxins / Furans - The Apex Instruments Method 23 (Modified Method 5) Source Sampler Kit is used for determination of dioxins and furans (D/F’s) in accordance with Method 23 and/or Determination of Semi-Volatile Organic Compounds as M0010. This train adds a water-cooled glass condenser, an XAD adsorbent module, and a large capacity knockout impinger to the Method 5 system. Method 29 (Multiple Metals) (page 55) Metal Emissions - Add up to three impingers, the SB-4 impinger case, glass nozzles, probe liners and non-metallic union to a...
Open the catalog to page 7ISOKINETIC SOURCE SAMPLING EQUIPMENT Isokinetic Source Sampling Equipment Modular Sample Cases, page 31 Probes and Liners, page 23
Open the catalog to page 8ISOKINETIC SOURCE SAMPLING EQUIPMENT Apex Instruments Isokinetic Source Sampling Systems are rugged, versatile equipment designed for extracting a representative sample of flue gas. The sample is used to determine particulate and toxic emissions in accordance with U.S. EPA Reference Methods as published in CFR 40 Part 60 Appendix A. Choose between automated or manual systems. Email: info@apexinst.com
Open the catalog to page 9ISOKINETIC SOURCE SAMPLING EQUIPMENT XC-5000 AutokineticTM Sampling Console Our XC-5000 AutoKinetic™ Series is designed for conducting US EPA Method 5 and associated isokinetic methods. Take the worry out of isokinetic sampling and the human error out of manual data entries and calculations. The XC-5000 Series is compatible with your existing Method 5 stack sampling components. Report preparation is streamlined with accurate data that can be downloaded for easy report preparation. ISOKINETIC SOURCE SAMPLING METER CONSOLE LEGEND - XC-5000 Power Output Option: BLANK = 4 Pin Amphenol (END OF...
Open the catalog to page 10ISOKINETIC SOURCE SAMPLING EQUIPMENT Autokinetic Software (Compatible Only with XC-5000 Console) The AutoKinetic proprietary software is designed to be intuitive and user friendly. The step-bystep Windows-based program guides the user through creating a test profile, ensuring that all test parameters are met, and managing the data. The software also allows for easy data export for report generation. Main Screen • • • • Access system functions Progress status Simple user interface Tabs to toggle between main, monitor and alert set-up screens Pre-Test Screens • Calculates: - Stack diameter...
Open the catalog to page 11ISOKINETIC SOURCE SAMPLING EQUIPMENT XC-500 Series Isokinetic Source Sampling Console - Manual The XC-500 series sampling console is a rugged, lightweight metering console used to extract gas samples in accordance with US EPA Method 5 for determining source emissions for dust and fumes. The Apex Instruments source sampler allows the operator to monitor gas velocities, temperatures, and pressures while adjusting sample flow rates to maintain isokinetic sampling conditions. The console comes with a digital or mechanical gas meter totalizer, digital temperature controllers and display, liquid...
Open the catalog to page 12ISOKINETIC SOURCE SAMPLING EQUIPMENT 500 Series Digital Isokinetic Source Sampling Console Apex instruments now offers the 500 series Method 5 isokinetic sampling consoles with a digital dry gas meter and digital volume display. At the core of the digital option is Apex Instrument’s custom-manufactured DGM-SK25EX-100 digital dry gas meter. The meter contains two internal digital transmissive components - the rotary codewheel and the optical encoder module. The components provide precision volume measurement at 1:1 ratio meter-cycle-to-codewheel resolution. The digital dry gas meter is...