Dual Color SRS Imaging

Dual Color SRS Imaging

Dual Color SRS Imaging

Product catalog summary
Overview: The document describes the deltaEmerald, a dual color Stimulated Raman Scattering (SRS) imaging system designed for simultaneous imaging of two vibrational bands. It highlights the system's innovative features, specifications, and applications in microscopy and imaging.
Key Features:
  • Simultaneous excitation of two vibrational bands using a dual color SRS scheme.
  • Tunable pump and Stokes pulses are spatially and temporally overlapped, with a spectral distance of 85 cm-1.
  • Proven Optical Parametric Oscillator (OPO) technology with shot noise limited performance at -162 dBc/Hz above 1 MHz.
  • Additional femtosecond output at 1030 nm for Second Harmonic Generation (SHG) and two-photon fluorescence (TPF) excitation.
Specifications:
  • Wavelengths: Stokes 1 at 1034 nm, Stokes 2 at 1025 nm, Pump (OPO Signal) between 740 nm and 990 nm.
  • Power: Stokes beams >300 mW unmodulated, >150 mW modulated; Pump >400 mW at 800 nm.
  • Pulse Characteristics: Pulse width of 1 ps, spectral bandwidth of 10 cm-1 to 15 cm-1, repetition rate of 80 MHz.
  • Beam Parameters: Pointing stability <100 µrad per 100 nm, M² <1.2, ellipticity <20%, linear polarization with horizontal >100:1.
Applications:
  • Simultaneous imaging of CH2 and CH3 for nondestructive and fast Coherent Raman histology.
  • Background removal of non-resonant artifacts, crucial for weak signals in the fingerprint region.
  • Applications in cosmetics, pharmaceutical imaging, and more.
Additional Features:
  • Integrated modulators for Stokes beams with built-in Electro-Optic Modulators (EOM) at fixed frequencies of 20 MHz and 13 MHz.
  • Automated delay management for microscope dispersion compensation.
  • Remote control via Ethernet TCP/IP.
Operational Requirements:
  • Power consumption: 100 V to 240 V, 50 Hz to 60 Hz, max. 10 A.
  • Operating temperature: 20°C to 25°C, with air conditioning recommended for stability.
  • Relative humidity: <60%.
Mechanical Dimensions: The deltaEmerald measures 961 mm x 781 mm x 277 mm and weighs 130 kg. The laser control unit and chiller are both 19 inch / 4U, weighing 10 kg and 14 kg respectively.
See more

Catalog excerpts

Dual Color SRS Imaging-1

deltaEmerald Dual Color SRS Imaging Dual Color SRS Imaging The new deltaEmerald allows simultaneous SRS imaging of two vibrational bands with its revolutionary dual color SRS (DC-SRS) scheme. It is aimed for users at the forefront of SRS microscopy, given the best signal-to-noise performance and the capability of background subtraction as well as simultaneous imaging of two vibrational bands. Two Stokes pulses, separated by 85 cm-1 and modulated at different frequencies are overlapped with the tunable Pump pulse. The pulse length of about 1 ps, 10 cm-1 ... 15 cm-1 bandwidth and several 100 mW output power in each beam are ideal parameters for Coherent Raman imaging. The pulses of all three beams are shot noise limited due to solid state laser design and proven OPO technology. The shot noise limited -162 dBc/Hz above 1 MHz (limited by the noise measurement setup with 4.8 mA) allows for fast image acquisition and superior signal-to-noise ratio. Fully automated tuning, power control and temporal overlap of all three beams are given. Additional a ~100 fs-output at 1030 nm is provided for efficient SHG and two-photon imaging. Innovative SRS scheme for simultaneous excitation of two vibrational band Tunable Pump and both Stokes pulses are spatially and temporally overlapped Spectral distance of Stokes 85 cm-1 Proven OPO technology with shot noise limited performance with -162 dBc/Hz above 1 MHz Additional femtosecond output at 1030 nm for optimum SHG and TPF excita

 Open the catalog to page 1
Dual Color SRS Imaging-2

deltaEmerald Dual Color SRS Imaging 1. Simultaneous imaging of CH2 & CH3 for nondestructive and fast Coherent Raman histology. The 85 cm-1 difference is chosen to address CH2 & CH3 with 2845 cm-1 and 2930 cm-1 at their peak position. 2. Background removal of non-resonant artefact's, especially important for weak signals in the fingerprint region. 3. Cosmetics / pharmaceutical imaging and further applications. Colon, courtesy of LightCore Technology Biospie, courtesy of LightCore Technology Specifications Wavelength Stokes 1 W avelength Pump (OPO Signal) Specifications P ower Stokes 1 P ower Pump...

 Open the catalog to page 2
Dual Color SRS Imaging-3

deltaEmerald Specifications S pectral bandwidth Pump and Stokes beam s S hot noise limited (-162 dBc/Hz) > 1 MHz (Pump and Stokes ) Beam Parameters Pointing stability Additional Femtosecond Output Wavelength

 Open the catalog to page 3
Dual Color SRS Imaging-4

Features Integrated modulators for Stokes beams Built-in EOM with resonant fixed frequency of 20 MHz and 13 MHz Integrated for Pump and Stokes, independent for each beam A utomated compensation for microscope dispersion Remote control Mechanical dimensions (L x W x H) / weight: deltaEmerald L aser control unit Further requirements: Power consumption Operating temperature 2 0°C … 25°C, air conditioning (stability ± 1°C) recommended Contact APE Angewandte Physik & Elektronik GmbH Plauener Str. 163-165|Haus N|13053 Berlin|Germany T: +49 30 986 011-30 F: +49 30 986 011-333 E: [email protected]...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.