Catalog excerpts
:: AP2E :: Parc de la Duranne – Les Méridiens, Bat A – 240 Rue Louis de Broglie – 13857 Aix en Provence Cedex 03 Tel : +33 (0)4 42 61 29 40 - Fax : +33 (0)4 42 61 29 01 - E-mail : info@ap2e.com S.A.S au capital de 246 670 € – Siret : 491 649 067 00023 – N° TVA : FR36491649067 PPrrooCCeeaass HH22SS VERY LOW CONCENTRATIONS (Non HC’s Matrices) PPrrooCCeeaass HH22SS:: A Novel LASER Infrared Spectrometer for Gas Analysis Unmatched Selectivity, Levels of Detection and Measurement Speed ProCeas ® H2S: Dihydrogen Sulfide Analyzer Patented OFCEAS Technology The ProCeas CO enables the detection and quantification of Carbon Monoxide at very low concentrations (0-200 ppb). The ProCeas CO relies on the patented Optical Feedback Cavity Enhanced Absorption Spectroscopy (OFCEAS) technology. This is a LASER Infrared technology, solely relying on a LASER as light source to scan the sample. Sensitivity & Dynamic Range The gas cell is equipped with extremely high reflectivity mirrors (>99.99%), enabling pathlength ranging from 1,000 to 10,000 meters (1-10 km; 0.6 – 6.2 miles) in a measurement vessel featuring an internal volume of only 15 mL. This gas sampling technique is known as Enhanced Cavity. This unique combination of high reflectivity, small volume and very long pathlength enables unmatched sensitivity (parts-per-billion) in very short times of integration (< 1 second). When dealing with higher concentration range measurement (parts-per-million), alternate mirrors can be selected to reduce the number of reflections (and therefore pathlength), thus providing the analyzer with a dynamic range greater than 104. Instrumental Response Drift The infrared source is a non-pulsed LASER which provides the analyzer with great metrological stability as a function of time. As a result, there is no instrumental response zero drift. The benefit is that calibration re-certifications are seldom needed (several months can elapse between calibration accuracy re-certifications without affecting the analytical performance of the analyzer). Selectivity / False Positive Response Rate The main technological difference between OFCEAS and Cavity Ring Down Spectroscopy (CRDS) is the patented Feedback technology allowing to tune the LASER and the measurement vessel to their resonance frequencies. This yields a 200 data points extremely high resolution spectrum, resulting in an optical resolution of 10 KHz (compared to the optical resolution of 1 MHz – 1,000 KHz – of the CRDS technology). This 100x improvement factor in optical resolution combined with the spectral range covered guarantees single analyte selectivity and lack of false positive response due to the presence of spectroscopically interfering chemicals in the sample matrix. Patented Low Pressure Sampling Ap2e’s patented low pressure (100 mbar) sampling system frees the integration from problems associated to high water vapor concentration and subsequent transfer line heating requirements. Low pressure sampling allows to work at temperatures much lower than the dew point temperature without risk of water condensation in the lines and / or optics. Ap2e’s patented low pressure sampling system frees the user from the installation and maintenance costs of high temperature sample transfer lines. Speed of Analysis Low pressure sampling system allows for faster sample transfer times (typically less than 0.5 seconds per meter of line). OFCEAS technology, when used with a low volume gas cell, allows for extreme sensitivity with integration times less than 1 second. The ProCeas H2S, by integrating both patented technologies into one dedicated complete analytical solutions, enables true real time measurement. ProCeas H2S - Advantages Chemical Selectivity (No False Positive) Extremely low LOD’s (measured in ppb’s) Wide Dynamic Range (ppb to ppm; range > 104) Short Response Time No Instrumental Response Drift Intrinsic Robustness of the Technology & Design Reduced Maintenance Ambient Temperature Sampling
Open the catalog to page 1:: AP2E :: Parc de la Duranne – Les Méridiens, Bat A – 240 Rue Louis de Broglie – 13857 Aix en Provence Cedex 03 Tel : +33 (0)4 42 61 29 40 - Fax : +33 (0)4 42 61 29 01 - E-mail : info@ap2e.com S.A.S au capital de 246 670 € – Siret : 491 649 067 00023 – N° TVA : FR36491649067 Product Specifications Sampling Flow Rate 3 – 9 Liters / Hour Maximum Operating Temperature 600ºC (~ 1,000F) Maximum Operating Humidity (absolute) 25% vol. (contact us for feasibility estimate if above) Measurement Operating Pressure X atm ± 100 mbar Pre-Installation & Installation Requirements Operating Temperature...
Open the catalog to page 2All AP2E catalogs and technical brochures
-
AP2E LASERCEM Analyzer
3 Pages
-
AP2E Ambient Air Analyzer
5 Pages
-
STEAM METHANE REFORMING
4 Pages
-
ProCeas® GENERAL analyzer
2 Pages
-
ProCeas® H2S analyzer
2 Pages
-
ProCeas® NH3 DeNOx analyzer
2 Pages
-
ProCeas® HCI analyzer
2 Pages
-
ProCeas® HCN analyzer
2 Pages
-
ProCeas® CH4 analyzer
2 Pages
-
ProCeas® NH3 analyzer
2 Pages
-
ProCeas® CO analyzer
2 Pages
-
ProCeas® O2 analyzer
2 Pages
-
ProCeas® SO2 Trace analyzer
2 Pages
-
ProCeas® H2O dryer analyzer
2 Pages
-
ProCeas® HF analyzer
2 Pages
-
ProCeas® N2O analyzer
2 Pages
-
ProCeas® H2O Trace analyzer
2 Pages
-
LaserCEM® gas analyzers
2 Pages
-
ProCeas SO2/SO3 analyzer
2 Pages
-
ProCeas H2O LNG analyzer
2 Pages
-
ProCeas H2 purity analyzer
2 Pages
-
ProCeas NH3 DeNOx a nalyzer
2 Pages
-
ProCeas NOx Trace analyzer
2 Pages
-
ProCeas H2 Trace analyzer
2 Pages
-
ProCeas H2S LNG analyzer
2 Pages
-
ProCeas CO Trace analyzer
2 Pages
-
ProCeas NH3 Trace analyzer
2 Pages
Archived catalogs
-
Epsilon 5000
2 Pages