Catalog excerpts
H 2 S LN G analyzer Pr o C e a s No sample pre-treatment No Heated Lines* Multi-Components Pre-Calibrated No interference No Drift Low l e ve l H 2 S in de te c tio n in Li qu i f i e d N atur a l Ga s* * The ProCeas H2S is a complete pre-calibrated laser infrared spectrometer for low level detection of H2S in natural gas and liquefied natural gas (LNG). The ProCeas H2S uses the patented OFCEAS (WO 03031949) IR Laser technology for enhanced specificity, selectivity, accuracy and stability (no instrumental response drift.) The ProCeas H2S uses a patented low-pressure sampling system (WO 2010058107) enabling low-cost installation thank to non-heated lines* and reduced maintenance. The ProCeas H2S is a complete, reliable, robust, low-cost and easy-to-use solution for the H2S analysis natural gas processes. DIRECT MEASUREMENT No sample pre-treatment. OFCEAS technology associated with low pressure sampling enables direct measurement. The low pressure in the sampling system removes any risk for chemicals adsorption/desorption and condensation in the line. NO INTERFERENCE OFCEAS technology associated with low pressure sampling provides exceptional selectivity, enabling simultaneous multi-component measurement without interferences, regardless of the matrix. NO RE-ZERO; NO DRIFT The zero information is contained in the signal, enabling automated and intrinsic re-zero of the analyzer. EASE-OF-USE The ProCeas is pre-calibrated for your application. Initially packaged in a standard 19”rack, it includes a touch screen interface and on-board PC for local / remote control and real time display / recording of results. EASE-OF-INTEGRATION The ProCeas allows digital (Ethernet, RS485, RS232, ModBus), analog and TDR I/O’s. ROBUSTNESS The ProCeas contains no optical moving parts and was designed and built strictly for industrial and on-board mobile applications. LOW MAINTENANCE High MTBF. In addition to containing no moving optical components, the IR sources (telecom type laser) are characterized by MTBF’s of 5 years. CLEAN LINES / FILTERS The low pressure sampling system enables low flow rates (3-9 L/h) without degrading response time. Accumulation of contaminants lines and filters is greatly reduced. SAFE ATEX compliant configuration available. * Requires ambient temperature > 10°C and H2O < 65 % vol
Open the catalog to page 1Flow Rate : H2O(g) < 65% vol. - Standard H2O(g) > 65% vol. – Study Required 1 atm. ± 100 mbar @ sampling point Sampling Line : Ambient Temp. > 10°C et H2O <65% vol. > Simple polytube (no heating) Ethernet Protocol; RS 485 RS 232; ModBus. Analog I/O; TDR I/O. Other I/O’s on request ANALYTICAL SPÉCIFICATIONS Rangea Gas min Ambient Temp. < 10°C et H2O >65% vol. > 80°C heated line standard 19”, 4U rack. Response Timec Zero Drift : DIMENSIONS Size : Wall mounted ATEX compliant integration INSTALLATION REQUIREMENTS Operating Temp. : Compressed Air : Power supply : 5.7” diagonal color touch screen...
Open the catalog to page 2All AP2E catalogs and technical brochures
-
AP2E LASERCEM Analyzer
3 Pages
-
AP2E Ambient Air Analyzer
5 Pages
-
STEAM METHANE REFORMING
4 Pages
-
ProCeas® GENERAL analyzer
2 Pages
-
ProCeas® H2S analyzer
2 Pages
-
ProCeas® NH3 DeNOx analyzer
2 Pages
-
ProCeas® HCI analyzer
2 Pages
-
ProCeas® HCN analyzer
2 Pages
-
ProCeas® CH4 analyzer
2 Pages
-
ProCeas® NH3 analyzer
2 Pages
-
ProCeas® CO analyzer
2 Pages
-
ProCeas® O2 analyzer
2 Pages
-
ProCeas® SO2 Trace analyzer
2 Pages
-
ProCeas® H2O dryer analyzer
2 Pages
-
ProCeas® HF analyzer
2 Pages
-
ProCeas® N2O analyzer
2 Pages
-
ProCeas® H2O Trace analyzer
2 Pages
-
LaserCEM® gas analyzers
2 Pages
-
ProCeas SO2/SO3 analyzer
2 Pages
-
ProCeas H2O LNG analyzer
2 Pages
-
ProCeas H2 purity analyzer
2 Pages
-
ProCeas NH3 DeNOx a nalyzer
2 Pages
-
ProCeas NOx Trace analyzer
2 Pages
-
ProCeas H2 Trace analyzer
2 Pages
-
ProCeas CO Trace analyzer
2 Pages
-
ProCeas NH3 Trace analyzer
2 Pages
Archived catalogs
-
Epsilon 5000
2 Pages
-
ProCeas H2S
2 Pages