hydrogen purity - ISO 14687-2 - application note

hydrogen purity - ISO 14687-2 - application note

hydrogen purity - ISO 14687-2 - application note

Product catalog summary
Introduction
The document discusses the ProCeas® hydrogen purity analyzer, emphasizing its accuracy, ease of use, fast response time, low maintenance, and no drift characteristics. It is designed for multicomponent and highly sensitive analysis of hydrogen purity.
Recommendations for Impurity Levels
According to ISO 14687-2, there are specified critical impurities and maximum levels that need to be detected in hydrogen to ensure its purity.
Technology Overview
The ProCeas® utilizes patented OFCEAS technology, which is based on extractive absorption spectroscopy. This laser-based technology can measure gas concentrations down to sub-ppb levels with high accuracy and repeatability. The system operates at low pressure, requiring minimal hydrogen samples, and features integrated auto-calibration to prevent drift.
Importance of Controlling Impurities
Controlling impurities in hydrogen is crucial as it is increasingly used as a clean energy source. Impurities can affect the lifespan of fuel cells, engines, and turbines, with gases like sulfur and halogenated compounds posing significant risks.
Key Features of ProCeas®
  • Highly sensitive with low detection levels (sub-ppb)
  • Pre-calibrated laser infrared spectrometer
  • No zero or span drift, eliminating the need for daily calibration
  • No requirement for nitrogen, zero air, purge, or other carrier gases
  • Multigas analysis capability (H2S, CO, CO2, CH4, O2, NH3, H2O, HCHO, etc.)
  • Minimal sample volume needed for analysis
Contact Information
For further inquiries, contact details are provided for the company located in Aix-en-Provence, France.
See more

Catalog excerpts

hydrogen purity - ISO 14687-2 - application note-1

APPLICATION NOTE The accurate analyzer for h2 purity control Multicomponent and highly sensitive Ease of use and fast response time Low maintenance and no drift

 Open the catalog to page 1
hydrogen purity - ISO 14687-2 - application note-3

WHY DO YOU NEED TO CONTROL IMPURITIES IN HYDROGEN ? In a time when the world is looking for cleaner sources of energy, hydrogen is seen by many as an interesting alternative for cars, trains, etc. The fast evolution of the hydrogen sector brings industrials to find new solutions to control the purity of hydrogen. Quality of hydrogen is critical to insure that impurities does not affect the lifetime of fuel cells, engines, turbines. Gas such as sulfur and halogenated compounds can be problematic. What are the recommendations for maximum content of impurities? ISO 14687-2 specifies the critical...

 Open the catalog to page 3
hydrogen purity - ISO 14687-2 - application note-4

ProCeas® key features •Highly sensitive • Low detection level (sub-ppb) • Complete pre-calibrated laser infra-red spectrometer • No Zero drift and no Span drift – No daily calibration required • No nitrogen, zero air, purge or other carrier gas • Multigas analyser (H2S, CO, CO2, CH4, O2, NH3, H2O, HCHO, etc.) • Limited volume of sample needed for an analysis ProCeas® hydrogen purity Is a complete pre-calibrated multicomponent (H2S, CO, CO2, CH4, H2O, O2, NH3, H2O, HCHO, etc.) laser infrared spectrometer for measurements of impurities in hydrogen. limit of detection 3 Sigma 240, rue Louis de Broglie...