WL series
1 /19Pages

WL series

WL series
1 /19Pages

Catalog excerpts

WL series-1

The Manual of Pump Model Selection for: WL MODEL VERTICAL SEWAGE PUMP

 Open the catalog to page 1
WL series-2

Brief account of product Main purpose Model description WL Series pump performance table WL Type vertical sewage pump installation dimension figure and dimension table Failures causes and troubleshooting

 Open the catalog to page 2
WL series-3

WL SERIES VERTICAL SEWAGE PUMP BRIEF ACCOUNT OF PRODUCT WL series vertical sewage pump is a new-generation prod- uct successfully developed by this Co. by way of introducing the advanced know-how from both at home and abroad, upon the requirements and conditions of use of the users and reasonable designing and features high efficiency, energy saving, flat power curve, non-block-up, wrapping-resisting, good performance etc. This series pump uses single(dual) great flow-path impeller or the impeller with dual or three baldes and, with the unique impeller`s structure, has a very good flow-passing...

 Open the catalog to page 3
WL series-4

jfcnn±£II& MAIN PURPOSE This product is mainly used to transport city's living sewa- ge, factory, mine etc. enterprises'sewage, slurry, night soil, ash and dregs, paper pulp etc. also for cycle water pump, water supply and drain pumps, exploration, mine fitted auxiliary m- achine, methane-generating pit in countryside, farming irriga- M-^-iftBJj MODEL DESCRIPTION '-%#llBSSfr^ (kW) Fitted power of motor(kw) '-ISS^ST© (m) Rated head(m) -H^^rtM (m7h) Rated flow(mVh) 1&^7J S I— EfeflUn-Kttl&S Jointed with extended shaft of motor Way of joint II— Jointed with clutch 1-JA^If^^ Vertical sewage pump...

 Open the catalog to page 4
WL series-5

WL SERIES VERTICAL SEWAGE PUMP DESCRIPTION OF STRUCTURE WL series vertical non-block-up sewage pump is a sin- gle-suction spiral casing type one and inside of it there are non-block-up wrapping-resisting single(dual) great flowpath impeller(s) mounted and both pump casing and inlet pipe are set hand holes for draining foreign matters. Two structural forms with the pump, one is the coaxial structure of both pump and motor, in which the extended shaft of the motor is directly connected to the impeller of the pump; the other is the motor is mounted on the stand integrated with the pump casing and...

 Open the catalog to page 5
WL series-6

WL SERIES PUMP PERFORMANCE TABLE / Outlet caliber/lnler caliber

 Open the catalog to page 6
WL series-7

WL SERIES VERTICAL SEWAGE PUMP WL SERIES PUMP PERFORMANCE TABLE / Outlet caliber/lnler caliber

 Open the catalog to page 7
WL series-8

WL SERIES PUMP INSTALLATION PERFORMANCE TABLE / Outlet caliber/lnler caliber

 Open the catalog to page 8
WL series-9

WL SERIES VERTICAL SEWAGE PUMP WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION FIGURE Inlet flang Outlet flang

 Open the catalog to page 9
WL series-10

WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION TABLE Inlet flange Outlet flange

 Open the catalog to page 10
WL series-11

WL SERIES VERTICAL SEWAGE PUMP WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION TABLE Inlet flange Outlet flange

 Open the catalog to page 11
WL series-12

WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION TABLE Inlet flange Outlet flange

 Open the catalog to page 12
WL series-13

WL SERIES VERTICAL SEWAGE PUMP WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION FIGURE Outlet flang

 Open the catalog to page 13
WL series-14

WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION TABLE Inlet flange No. Outlet flange

 Open the catalog to page 14
WL series-15

WL SERIES VERTICAL SEWAGE PUMP WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION TABLE Inlet flange Outlet flange

 Open the catalog to page 15
WL series-16

WL(I) TYPE VERTICAL SEWAGE PUMP DIMENSION TABLE Inlet flange No. Outlet flange

 Open the catalog to page 16
WL series-17

WL SERIES VERTICAL SEWAGE PUMP INSTALLATION AND USE 1 A stand should be used to connect the pipeline of the p- ump and do not let the weight of the pipeline supported by the pump casing. 2.For the sake of safe use, mount a regulation valve separately on both inlet and outlet pipelines of the pump and a piezometer on the outlet to ensure the pump to run under the set working conditions so as to make sure of its normal running and raise its duration. 3.In installation, tighten the foot bolts, check if both pump and motor tightened and damaged. 4.When to transport high-temperature liquids, the foot...

 Open the catalog to page 17
WL series-18

titP*J5III3Utt&2Fi£ FAILURES CAUSES AND TROUBLESHOOTING

 Open the catalog to page 18
WL series-19

由于我们在不断努力改进产品我们保留更改样本数据的权利敬请谅解 As we are constantly endeavouring to improve the performance of our equipment. The company reserves the right to make alteration from time to time and equipment differ from that detailed in this brochure. Shanghai Aoli Pump Manufacture Co. Ltd. Add: No. 718, South Shangxin Road, Nanxiang Hi-tech Development Park, Jiading District, Shanghai, 201802, China Tel: 86 21 69172008 Ext. 811 86 21 39170017(direct) Fax: 86 21 39170010 Web: www.made-in-china.com/showroom/aolipumpcn www.aolipump.cn E-mail: [email protected] [email protected] MSN: [email protected]...