Group: ASGARD
Catalog excerpts
TM 6602 / 6612 / 6630 Handheld thermometers for thermocouples and/or resistive probes with memory TM thermometers are the perfect field tools for daily maintenance and commissioning of temperature probes at 0.02% accuracy.
Open the catalog to page 1Description Easy-to-use and equipped with a large graphical display, TM thermometers are the perfect field tools for daily maintenance and commissioning of temperature probes. 3 models are available with 0.02% accuracy as follows: TM 6602 for thermocouple measurement TM 6612 for RTD measurement TM 6630 for both thermocouple and RTD measurement With a very low temperature coefficient (10 ppm/°C in thermocouples and 7ppm/°C in resistance), IP54 protection and robust design, TM thermometers are suitable for onsite use even in demanding environmental conditions. They are widely used in the...
Open the catalog to page 2Specifications Specifications and performances of TM 6602 / 6630 @23°C ±5°C DC voltage Function Measuring range Temperature coefficient < 15 ppm/°C beyond reference domain Thermocouples: Measurement Type Input range Accuracy / 1 year (Measurement)
Open the catalog to page 3Thermocouples G, D: For specifications, refer to the instruction manual (Available on request) Accuracy is given for reference @ 0°C. When using the internal reference junction (except couple B) add an additional uncertainty of 0.3 °C at 0 °C. It is possible (thermocouple B excepted) to choose by programming the cold junction localization: External at 0°C, internal (temperature compensation of instrument’s terminals) or manually entered. Temperature coefficient: <10% of accuracy /°C Specifications and performances of TM 6612 / 6630 @23°C ±5°C Resistance Function Automatic detection: 2, 3 or...
Open the catalog to page 4Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Take into account particular error of temperature sensor used and implementation conditions Measuring current: 0.65 mA Temperature coefficient: < 10% of accuracy /°C Further features Calibrated sensors A database can be created to design curves for sensor s after calibration according to the corrections mentioned on a calibration report. Data recording Data are recorded either manually on event or automatically with...
Open the catalog to page 5Environmental specifications Reference range Operating reference range Limit operating range Storage temperature limits Maximum height Safety specifications Protections Electronic protection up to 250 V for ‘voltage’ wires Fuse protection for ‘current’ wires Protection against ‘current’ circuit breaking during inductive resistance measurements In accordance with EN 61010-1 Category II, pollution 2 Rated voltage EN 61000-4-4 Conducted and radiated emissions: EN 55022, class B EN 61000-3-2 EN 61000-3-3
Open the catalog to page 6Handheld thermometer for thermocouples with memory Delivered in standard with: • User manual • Protection sheath • Carrying strap • Factory test report TM 6612 Handheld thermometer for resistive probes with memory Delivered in standard with: • User manual • Protection sheath • Carrying strap • Factory test report TM 6630 Handheld thermometer for thermocouples and resistive probes with memory Delivered in standard with: • User manual • Protection sheath • Carrying strap • Factory test report AC6908 Soft carrying case for hand-held instruments AN6011 Charger + batteries for hand-held...
Open the catalog to page 7ACC-A-R Male compensated plug type LNRBEUC or D T101 Flexible type K sensor T102 Rigid K type sensor T703A Surface temp, sensor K couple T704 Surface K sensor + springplate ER 48457-000 4-pin circular connector for PtlOO* S101D PtlOO environment sensor S102D PtlOO immersion sensor S103 Flexible housing sensor This accessory is necessary for RTDs with bare wires DATACAL TCTM Calibration software for TC / TM series Supplied with USB cable mini B QMA11EN COFRAC certificate of calibration With all relevant data points where the device has been tested Packing information: Weight without packing...
Open the catalog to page 8All AOIP catalogs and technical brochures
-
RAYOMATIC 16
7 Pages
-
RLV
5 Pages
-
EPM
10 Pages
-
UNIGAS 3000
7 Pages
-
RN 5306
5 Pages
-
LKS 1000 Leakshooter camera
6 Pages
-
TTI 10
6 Pages
-
RN 5360
5 Pages
-
MEGOHM 200
7 Pages
-
MF 28
6 Pages
-
CALYS 1000
7 Pages
-
IND 45
6 Pages
-
CALYS 1500
12 Pages
-
RAYOMATIC USB 2.2
6 Pages
-
RAYOMATIC PE
6 Pages
-
RAYOMATIC USB
6 Pages
-
IRTEC P IVT
5 Pages
-
RAYOMATIC 16 2.2
6 Pages
-
RAYOMATIC NET
6 Pages
-
RAYOMATIC TC
6 Pages
-
ICO 51
6 Pages
-
LKS 1000
5 Pages
-
MILLIK
7 Pages
-
TC 6621 / 6622
10 Pages
-
SN 8310
7 Pages
-
CALYS 60 IS
9 Pages
-
CP 6632
7 Pages
-
THERMYS 150
10 Pages
-
CALYS 120 IS
12 Pages
-
ZX
5 Pages
-
OM 10
6 Pages
-
OM 21
8 Pages
-
ISOPALM 200
7 Pages
-
CRIT 100
4 Pages
-
IRtec P
11 Pages
-
FD 5 / 10 / 15
12 Pages
-
VNE20
5 Pages
-
OM 16
8 Pages
-
SATURN CYCLOP 878
4 Pages
-
CALYS 80 IS
11 Pages
-
CALYS 80P
10 Pages
-
P200 PRO
8 Pages
-
CALYS 150
8 Pages
-
motor starter
4 Pages
-
Frontdaq 10 isolated channels
4 Pages
-
Data Acquisition Systems DATALOG
12 Pages
-
Accuracy Thermometer PHP 602
2 Pages