Handheld temperature calibrators for thermocouples or resistive probes with memory TC 6621 measures or generates thermocouple temperatures (16 different types) and voltage at an accuracy of 0.02%. TC 6622 measures or generates RTD temperatures (12 different types) and resistance at an accuracy of 0.02%.
Open the catalog to page 1Description Easy-to-use and equipped with a large graphical display, TC temperature calibrators are the perfect field tools for easy and quick maintenance and commissioning of temperature transmitters and probes. TC 6621 measures or generates thermocouple temperatures (16 different types) and voltage at an accuracy of 0.02%. TC 6622 measures or generates RTD temperatures (12 different types) and resistance at an accuracy of 0.02%. With a very low temperature coefficient (10 ppm/°C in thermocouples and 7ppm/°C in resistance), IP54 protection and robust design, TC calibrators are suitable for onsite...
Open the catalog to page 2Specifications Specifications and performances of TC 6621 @23°C ±5°C DC voltage Function Measuring range Temperature coefficient < 15 ppm/°C beyond reference domain Thermocouples: Measurement and simulation Type Input range Resolution Accuracy / Output 1 year (Me range asurement) Accuracy / 1 year (Simulation )
Open the catalog to page 3Thermocouples G, D: For specifications, refer to the instruction manual (Available on request) Accuracy is given for reference @ 0°C. When using the internal reference junction (except couple B) add an additional uncertainty of 0.3 °C at 0 °C. It is possible (thermocouple B excepted) to choose by programming the cold junction 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38
Open the catalog to page 4localization: External at 0°C, internal (temperature compensation of instrument’s terminals) or manually entered. Temperature coefficient: <10% of accuracy /°C Specifications and performances of TC 6622 @23°C ±5°C Resistance Function Automatic detection: 2, 3 or 4 wires Automatic detection: 2, 3 or 4 wires Connection in resistance and RTDs through banana plugs or 4-pin round connector Temperature coefficient: < 7 ppm/°C beyond reference domain Rising time in simulation: < 1 ms R internal: < 1 Ω Noise VLF < 1 mV (@ F< 100 Hz) Resistive probes: Measurement and simulation Sensor Range (Input and...
Open the catalog to page 5Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Take into account particular error of temperature sensor used and implementation conditions Measuring current: 0.65 mA Simulation current: 0.1 mA to 1mA Minimal current pulse duration: < 1 ms Temperature coefficient: < 10% of accuracy /°C Further features Scaling in measurement and simulation modes This function allows sensors to be corrected after a calibration. Scaling is performed using up to 10 segments, in order to...
Open the catalog to page 6General specifications Size 160 x 160 pixel liquid crystal graphical display with backlite Display of result as table of values or trend curve Power supply 4 AA batteries 1.5 V or rechargeable Ni-Mh batteries with internal charger in option Communication ports Storage capacity 10,000 data with date and time into one or several acquisition bursts Environmental specifications Reference range Operating reference range Limit operating range Storage temperature limits Maximum height Safety specifications Protections Electronic protection up to 250 V for ‘voltage’ wires Fuse protection for ‘current’...
Open the catalog to page 7EN 61000-4-4 Conducted and radiated emissions: EN 55022, class B EN 61000-3-2 EN 61000-3-3
Open the catalog to page 8Models and accessories Instrument: TC 6621 Handheld calibrator for thermocouples with memory Delivered in standard with: User manual 4 AA batteries Protection sheath Carrying strap Factory test report TC 6622 Handheld calibrator for resistive probes with memory Delivered in standard with: User manual 4 AA batteries Protection sheath Carrying strap Factory test report Male compensated plug type T Male compensated plug type J Male compensated plug type S Male compensated plug type K Male compensated plug type LNRBEUC or D Flexible type K sensor Rigid K type sensor Surface temp. sensor K couple...
Open the catalog to page 9Flexible housing sensor *This accessory is necessary for RTDs with bare wires Soft carrying case for hand-held instruments Charger + batteries for hand-held instruments Software: DATACAL TCTM Calibration software for TC / TM series Supplied with USB cable mini B COFRAC certificate of calibration With all relevant data points where the device has been tested Packing information: Size Weight without packing 306 g
Open the catalog to page 105 Pages
10 Pages
10 Pages
6 Pages
5 Pages
10 Pages
5 Pages
6 Pages
7 Pages
7 Pages
5 Pages
7 Pages
6 Pages
6 Pages
12 Pages
6 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
5 Pages
7 Pages
8 Pages
7 Pages
9 Pages
7 Pages
10 Pages
12 Pages
5 Pages
6 Pages
8 Pages
7 Pages
4 Pages
11 Pages
12 Pages
5 Pages
8 Pages
4 Pages
11 Pages
6 Pages
8 Pages
4 Pages
10 Pages
12 Pages
4 Pages
2 Pages
6 Pages