OM 10
1 /6Pages

OM 10

OM 10
1 /6Pages

Catalog excerpts

OM 10-1

Onsite micro-ohmmeter up to 50 KΩ and 100 mA OM 10 micro-ohmmeter performs 4-wire measurements of inductive and non-inductive resistances up to 50 kΩ with continuous or pulse measuring current up to 100 mA. It works at a resolution of 10 µΩ and an accuracy of 0.05%. The accuracy of measurements is also ensured by the automatic compensation of thermal electromagnetic forces, the compensation of ambient temperature (internal sensor) at 20°C and by the selection of the metal type.OM 10 can also measure DC and AC voltages up to 400 V.

 Open the catalog to page 1
OM 10-2

Description OM 10 micro-ohmmeter performs 4-wire measurements of inductive and non-inductive resistances up to 50 kΩ with continuous or pulse measuring current up to 100 mA. It works at a resolution of 10 µΩ and an accuracy of 0.05%. The accuracy of measurements is also ensured by the automatic compensation of thermal electromagnetic forces, the compensation of ambient temperature (internal sensor) at 20°C and by the selection of the metal type. OM 10 can also measure DC and AC voltages up to 400 V. Key-features : 4-wire resistance measurement up to 50 kΩ at 10 µΩ resolution and 0.05% accuracy...

 Open the catalog to page 2
OM 10-3

Specifications Resistance measurement Measurement range Measuring current Voltage drop Accuracy given in % of reading + fixed value at 23°C ±5°C Temperature coefficient beyond operating range: < 10% accuracy/°C (from 0 to18°C and from 28 to 50°C) Open circuit voltage: < 8 V Resistance of the connection cables: < 20 Ω Voltage measurement Range Accuracy given in % of reading + fixed value at 23°C ±5°C Temperature measurement Range Accuracy given in % of reading + fixed value at 23°C ±5°C Further features Resistance types Inductive resistances: Coils, transformers, motor windings... Non-inductive...

 Open the catalog to page 3
OM 10-4

Measurement current DC current from 0.01 mA to 100 mA Continuous ou pulsed Measurement time 0.5 s in DC current mode or 1 s in pulsed mode Automatic compensation of EMF parasites before each measurement for a greater accuracy Temperature compensation Choice of metal temperature coefficient Choice of ambient temperature (programmed or measured with internal sensor) Temperature compensation at 20°C: Resolution: 0.1°C, accuracy: ±0.5°C (R20 = Resistance compensated at ambient temperature equal to 20°C General specifications Size Power supply Internal batteries Type: Ni/Cd 1.7 Ah Charging time: 14...

 Open the catalog to page 4
OM 10-5

Protection against ‘current’ circuit breaking during inductive resistance measurements Class In accordance with EN 61010-1 Category III, pollution 2 Rated voltage Chocks and vibrations EN 50082-1/1992 Radiated: CEI 801-3/1984 Conducted: CEI 801-4/1988. Electrostatic discharges : CEI 801-2/1991 Conducted and radiated emissions: EN 55022, class B

 Open the catalog to page 5
OM 10-6

Models and accessories Instrument: OM10 On-site micro-ohmmeter Clips and probes: Please note that 2 clips are needed per OM 10. AN5806-2 Gold plated Kelvin clips, set of 2 Opening diameter: 12 mm, cable length: 2 m Kelvin clips, set of 2 Opening diameter: 12 mm, cable length: 3 m Test probe, per unit Cable length: 5 m Kelvin clip, per unit Opening diameter: 25 mm, cable length: 3 m COFRAC certificate of calibration

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.